Augmentation of the aortic and central arterial pressure waveform
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Late systolic augmentation of the ascending aortic and central arterial pressure wave is a characteristic feature of aging, and is attributable to stiffening of the aorta and major central arteries. It is caused by increased pulse wave velocity in these vessels with early return of wave reflection from peripheral sites, predominantly in the lower part of the body. Augmentation is measurable through identification of the shoulder or early systolic peak of pressure, which corresponds to peak flow in the aorta, and measurement from this point to the second peak, or shoulder of the wave in late systole. Difficulties in measurement of augmentation arise from problems in identification of the initial shoulder, especially when this is close to the foot of the reflected wave, to amplification of the pulse wave between ascending aorta and carotid artery, and to a Venturi effect in the aorta at the peak of aortic flow. Augmentation is systematically higher in the left ventricle than in the aorta, and systematically higher in the aorta than in more peripheral arteries such as the carotid or radial. Since properties of upper limb arteries are relatively constant with age, blood pressure, gender and drug therapy, a generalized transfer function can be used to synthesize the aortic from the radial pressure waveform. Comparison of measured directly and aortic pressure calculated with the SphygmoCor process under control conditions and with nitroglycerine infusion gave values of augmentation with mean difference 0.9, SD 7.7 mmHg, which lie within AAMI criteria for equivalence, as do measures of end systolic pressure (difference 3.8, SD 3.6 mmHg).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
Self-citationArterial wave reflections and survival in end-stage renal failure
London, G. M., Blacher, J., Pannier, B., Guérin, A. P., Marchais, S. J., & Safar, M. E. (2001) · Hypertension · doi:10.1161/01.hyp.38.3.434 · Cited by 853
Research works printed but not linked: 27
- Mahomed, 1872, Med Times Gazette, 1, 62???65
- O??Rourke, 1992, Hypertension, 19, 212???217
- Murgo, 1980, Circulation, 61, 105???116
- Patel, 1965, J Appl Physiol, 210, 459???463
- O??Rourke, 1966, Circ Res, 18, 126???139
- O??Rourke, 1967, Circ Res, 20, 365???380
- O??Rourke, 1970, Circ Res, 27, 123???133
- Taylor, 1966, Biophysics J, 6, 29???51
- O??Rourke, 1967, J Appl Physiol, 23, 139???149
- Smulyan, 2001, J Am Coll Cardiol, 37, 1374???1380, 10.1016/S0735-1097(01)01166-4 · DOI · Paper page
- Wilkinson, 2000, J Physiol, 525, 263???270
- Gatzka, 2001, Am J Hypertens, 14, 573???577, 10.1016/S0895-7061(00)01320-0 · DOI
- Kingwell, 2002, J Hypertens, 20, 2337???2340, 10.1097/00004872-200212000-00006 · DOI
- Hope, 2003, J Hypertens, 21, 1299???1305
- Chen, 1997, Circulation, 95, 1827???1836
- Smulyan, 2003, Hypertension, 42, 150???155, 10.1161/01.HYP.0000084051.34269.A9 · DOI · Paper page
- O??Rourke, 2004, J Hypertens, 22, 413???433
- Kelly, 1989, J Vasc Med Biol, 1, 142???149
- O??Rourke, 2002, Am J Hypertens, 15, 426???444
- O??Rourke, 2003, Minerva Medica, 94, 229???250
- London, 1992, Hypertension, 20, 10???19, 10.1161/01.HYP.20.1.10 · DOI · Paper page
- Takazawa, 1987, J Tokyo Medical College, 45, 256???270
- Millasseau, 2003, Hypertension, 41, 1016???1020, 10.1161/01.HYP.0000057574.64076.A5 · DOI · Paper page
- Hoeks, 2003, J Hypertens, 21, 1241???1243
- Mitchell, 2003, Circulation, 108, 1592???1598, 10.1161/01.CIR.0000093435.04334.1F · DOI · Paper page
- Kelly, 1989, J Vasc Med Biol, 1, 241???247
- Chen, 1996, Hypertension, 27, 168???175
Cited by
The CAFE Investigators, CAFE Steering Committee and Writing Committee, Williams, B., Lacy, P. S., Thom, S. M., Cruickshank, K., Stanton, A., Collier, D., Hughes, A. D., Thurston, H., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.595496 · Cited by 1,645
Self-citationTownsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms
NICHOLS, W. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2004.10.009 · Cited by 1,001
Chirinos, J. A., Zambrano, J. P., Chakko, S., Veerani, A., Schob, A., Willens, H. J., Perez, G., & Mendez, A. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000165025.16381.44 · Cited by 364
A Wearable and Highly Sensitive Graphene Strain Sensor for Precise Home-Based Pulse Wave Monitoring
Yang, T., Jiang, X., Zhong, Y., Zhao, X., Lin, S., Li, J., Li, X., Xu, J., Li, Z., & Zhu, H. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00230 · Cited by 321
Metadata
- Authors
- O??Rourke, M. F., & Pauca, A. L.
- Venue
- Blood Pressure Monitoring
- Published
- 2004-08
- Volume
- 9
- Issue
- 4
- Pages
- 179-185
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W1983663033
- Cited by
- 112
- References
- 2
- FWCI
- 4.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Augmentation of the aortic and central arterial pressure waveform. https://app.cochat.ai/papers/10.1097/00126097-200408000-00002
- The paper
- O??Rourke, M. F., & Pauca, A. L. (2004). Augmentation of the aortic and central arterial pressure waveform. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200408000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.