Recommendations for blood pressure measuring devices for office/clinic use in low resource settings

Open access
Parati, Gianfranco, Mendis, Shanthi, Abegunde, Dele, Asmar, Ronald, Mieke, Stephan, Murray, Alan, Shengelia, Bakuti, Steenvoorden, Gijs +2 more·2005·Blood Pressure Monitoring

Abstract

This paper, which summarizes the conclusions of a WHO Expert meeting, is aimed at proposing indications to develop technical specifications for an accurate and affordable blood pressure measuring device for office/clinic use in low resource settings. Blood pressure measuring devices to be used in low resource settings should be accurate, affordable, and easily available worldwide. Given the serious inherent inaccuracy of the auscultatory technique, validated and affordable electronic devices, that have the option to select manual readings, seem to be a suitable solution for low resource settings. The agreement on the technical specifications for automated blood pressure measuring devices for office/clinic use in low resource settings included the following features: high accuracy, adoption of electronic transducers and solar batteries for power supply, standard rates of cuff inflation and deflation, adequate cuff size, digital display powered by solar batteries, facilities for adequate calibration, environmental requirements, no need of memory function, resistance to shock and temperature changes, and low cost. Availability of a device with these features should be accompanied by adequate training of health care personnel, who should guarantee implementation of the procedures recommended in recent European and American Guidelines for accurate blood pressure measurement.

Integrity signals

Registry

Crossref · 10.1097/00126097-200502000-00002

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Parati, G., Mendis, S., Abegunde, D., Asmar, R., Mieke, S., Murray, A., Shengelia, B., Steenvoorden, G., Van Montfrans, G., & O??Brien, E.
Affiliations
  • IRCCS Istituto Auxologico Italiano (IT)
  • World Health Organization (CH)
  • Physikalisch-Technische Bundesanstalt (DE)
  • Freeman Hospital (GB)
  • Netherlands Organisation for Applied Scientific Research (NL)
Corresponding author
Parati, Gianfranco
Venue
Blood Pressure Monitoring
Published
2005-02
Volume
10
Issue
1
Pages
3-10
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2160348659
Cited by
60
References
0
Citations by year
2025: 1 · 2024: 4 · 2023: 1 · 2022: 4 · 2021: 1 · 2020: 2 · 2018: 3 · 2017: 2 · 2016: 1 · 2015: 4 · 2014: 6 · 2013: 1 · 2012: 3
FWCI
3.40
Type
journal article
Language
en
Open access
Locations
  • Blood Pressure Monitoring (publishedVersion)
  • PubMed (publishedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
  • TNO Repository (submittedVersion)
  • Pure Amsterdam UMC (submittedVersion)
  • Repository hosted by TU Delft Library (TU Delft) (submittedVersion)
  • Newcastle University ePrints (Newcastle Univesity)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
Keywords
blood pressure measuring devices, automated blood pressure measurement, resource-limited settings, technical specifications, electronic transducers, solar batteries, cuff size, calibration, health care personnel training
MeSH terms
Blood Pressure Determination, Equipment Design, Health Resources, Humans, Office Visits, Reference Standards, Solar Energy, Transducers, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review