Abstract

BACKGROUND: Viral load is a determinant of HIV-1 progression and transmission. Iron status and the phenotype of haptoglobin, a heme-binding acute phase reactant, may be determinants of viral load. We aimed to describe the effect of iron status, haptoglobin phenotype (Hp), and other predictors on HIV-1 viral load. METHODS: Based on a cross-sectional study among 1669 antenatal care attenders (22-35 weeks) in Zimbabwe, 526 (31.5%) were found to be HIV infected. The role of season, age, gravidity, gestational age, malaria parasitemia, Hp, and elevated serum alpha(1)-antichymotrypsin (ACT) as well as serum ferritin, folate, retinol, and beta-carotene on HIV viral load among the 526 HIV-infected women was assessed using multiple linear regression analysis. RESULTS: The distribution of Hp 1-1 (32%), Hp 2-1 (48%), and Hp 2-2 (20%) was not different from that of 53 uninfected women. Mean viral load was 3.85 log(10) (95% CI: 3.77-3.93) genome equivalents (geq)/mL, ranging from 3.77 (95% CI: 3.64-3.90) geq/mL in women with Hp 1-1 to 4.05 (95% CI: 3.81-4.21) geq/mL in women with Hp 2-2. With elevated serum ACT controlled for, women with Hp 2-2 had viral loads twice (95% CI: 1.4-4.0, p =.002) that of women with Hp 1-1, whereas those with serum ferritin <6 micro g/L had viral loads less than one third (95% CI: 0.13-0.53, p =.013) that of women with serum ferritin >24 micro g/L. Viral loads were also higher in women enrolled in the early rainy season compared with the dry season, in gravidae 4+ compared with gravidae 1 through 3, and in those with moderately elevated compared with low serum alpha(1)-antichymotrypsin, but neither age, gestational age, serum folate, serum retinol, nor serum beta-carotene were predictors. CONCLUSION: Storage iron, Hp 2-2, and elevated ACT are independent positive predictors of HIV-1 viral load. The positive relationship between serum ferritin and viral load was not the result of an acute phase response or iron accumulation with advanced HIV infection. A possible detrimental role of iron in HIV infection would have serious public health implications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126334-200305010-00011

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 43

Metadata

Authors
Friis, H., Gomo, E., Nyazema, N., Ndhlovu, P., Krarup, H., Madsen, P. H., & Michaelsen, K. F.
Venue
JAIDS Journal of Acquired Immune Deficiency Syndromes
Published
2003-05
Volume
33
Issue
1
Pages
74-81
ISSN
1525-4135 (ISSN-L)
OpenAlex
W2022956267
Cited by
43
References
1
FWCI
1.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Iron, Haptoglobin Phenotype, and HIV-1 Viral Load: A Cross-Sectional Study Among Pregnant Zimbabwean Women. https://app.cochat.ai/papers/10.1097/00126334-200305010-00011
The paper
Friis, H., Gomo, E., Nyazema, N., Ndhlovu, P., Krarup, H., Madsen, P. H., & Michaelsen, K. F. (2003). Iron, Haptoglobin Phenotype, and HIV-1 Viral Load: A Cross-Sectional Study Among Pregnant Zimbabwean Women. JAIDS Journal of Acquired Immune Deficiency Syndromes. https://doi.org/10.1097/00126334-200305010-00011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.