Performance of an oral fluid rapid HIV-1/2 test: experience from four CDC studies
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the performance of a rapid HIV antibody test used with whole blood and oral fluid in settings where the test is likely to be used. DESIGN: In four separate studies, we compared the accuracy of the rapid test performed on whole blood and oral fluid specimens with the results of conventional HIV tests. METHODS: Oral fluid and whole blood from persons of unknown HIV status recruited from clinics, labor and delivery units, and outreach venues were tested with the OraQuick Advance rapid HIV-1/2 antibody test. Sensitivity and specificity were compared with results of the enzyme immunoassay (EIA) and Western blot algorithm used by the study sites. RESULTS: OraQuick sensitivity was 99.7% with whole blood and 99.1% with oral fluid from 327 persons who were HIV antibody positive by the conventional algorithm. OraQuick specificity was 99.9% with whole blood and 99.6% with oral fluid from 12 010 HIV-negative persons; EIA specificity was 99.7%. A cluster of 16 false-positive oral fluid tests occurred in one study, in which specificity was lower (99.0%) than in the other three studies (99.6-99.8%). CONCLUSIONS: In diverse settings in four studies, the OraQuick test showed high sensitivity and specificity for HIV antibody in whole blood and oral fluid specimens. Slightly more false-positive and false-negative results occurred with oral fluid than with whole blood, but performance with both specimen types was similar to, or better than, that of conventional EIAs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE USE OF CONFIDENCE OR FIDUCIAL LIMITS ILLUSTRATED IN THE CASE OF THE BINOMIAL
CLOPPER, C. J., & PEARSON, E. S. (1934) · Biometrika · doi:10.1093/biomet/26.4.404 · Cited by 5,003 · cited 1×
“Exact 95% confidence intervals for these proportions were calculated [11].”
MethodFiebig, E. W., Wright, D. J., Rawal, B. D., Garrett, P. E., Schumacher, R. T., Peddada, L., Heldebrant, C., Smith, R., Conrad, A., Kleinman, S. H., et al. (2003) · AIDS · doi:10.1097/00002030-200309050-00005 · Cited by 1,305 · cited 1×
“Seroconversion studies [3,17] and post-marketing surveillance [14] suggest that this EIA and the Western blot are less sensitive to early infection than some newer EIAs and rapid tests.”
Background(1989) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1989.03430240025008 · Cited by 327
Gallo, D. (1997) · JAMA · doi:10.1001/jama.1997.03540270080030 · Cited by 162 · cited 10×
“fluid rapid HIV-1/2 test: experience from four CDC studies Kevin P. Delaneya, Bernard M. Bransona, Apurva Uniyalb, Peter R. Kerndtc, Patrick A. Keenand, Krishna Jafaa,e, Ann D. Gardnerf, Denise J. Jamiesong and Marc Bulterysh opyright © L From the aDivision Centers for Diseas California, USA, th dDepartment of Fa USA,…”
BackgroundInfluentialGift, T. L., Pate, M. S., Hook, E. W., & Kassler, W. J. (1999) · Sexually Transmitted Diseases · doi:10.1097/00007435-199904000-00010 · Cited by 156 · cited 1×
“Thus, using the OraQuick test with oral fluid in outreach settings where obtaining blood specimens is not feasible will help to identify more HIV-positive persons, even though its sensitivity is slightly lower with oral fluid than with whole blood [19].”
MethodFoglia, G., Royster, G. D., Wasunna, K. M., Kibaya, R. M., Malia, J. A., Calero, E. K., Sateren, W., Renzullo, P. O., Robb, M. L., Birx, D. L., et al. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.8.3850-3852.2004 · Cited by 27 · cited 1×
“Our findings are consistent with the clinical trial data reported by the manufacturer to the FDA [3] and other evaluations [12,13].”
Result
Cited by
Diagnostic point-of-care tests in resource-limited settings
Drain, P. K., Hyle, E. P., Noubary, F., Freedberg, K. A., Wilson, D., Bishai, W. R., Rodriguez, W., & Bassett, I. V. (2014) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(13)70250-0 · Cited by 744
Salivary Biomarkers: Toward Future Clinical and Diagnostic Utilities
Yoshizawa, J. M., Schafer, C. A., Schafer, J. J., Farrell, J. J., Paster, B. J., & Wong, D. T. W. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00021-13 · Cited by 656
Identification of Pathogen and Host‐Response Markers Correlated With Periodontal Disease
Ramseier, C. A., Kinney, J. S., Herr, A. E., Braun, T., Sugai, J. V., Shelburne, C. A., Rayburn, L. A., Tran, H. M., Singh, A. K., & Giannobile, W. V. (2009) · Journal of Periodontology · doi:10.1902/jop.2009.080480 · Cited by 382
Baral, S., Trapence, G., Motimedi, F., Umar, E., Iipinge, S., Dausab, F., & Beyrer, C. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004997 · Cited by 370
Acceptability of HIV self-testing: a systematic literature review
Krause, J., Subklew-Sehume, F., Kenyon, C., & Colebunders, R. (2013) · BMC Public Health · doi:10.1186/1471-2458-13-735 · Cited by 332
Metadata
- Authors
- Delaney, K. P., Branson, B. M., Uniyal, A., Kerndt, P. R., Keenan, P. A., Jafa, K., Gardner, A. D., Jamieson, D. J., & Bulterys, M.
- Venue
- AIDS
- Published
- 2006-08-01
- Volume
- 20
- Issue
- 12
- Pages
- 1655-1660
- ISSN
- 0269-9370 (ISSN-L)
- OpenAlex
- W2054903986
- Cited by
- 164
- References
- 7
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.