CoChat

Behavior of Entropy/Complexity Measures of the Electroencephalogram during Propofol-induced Sedation: Dose-dependent Effects of Remifentanil

Open access
Ferenets, Rain, Vanluchene, Ann, Lipping, Tarmo, Heyse, Björn, Struys, Michel M. R. F. · 2007 · Anesthesiology
Cited by 79

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Several new measures based on the regularity of the electroencephalogram signal for the assessment of depth of anesthesia/sedation have been proposed recently. In this study we analyze the influence of remifentanil and electroencephalogram frequency content of the performance of a set of such measures. Methods: Forty-five patients with American Society of Anesthesiologists physical status I were randomly allocated to one of three groups according to the received dose of predicted effect compartment-controlled remifentanil (0, 2, and 4 ng/ml). All 45 patients received stepwise increased effect site concentration-controlled dose of propofol. At every step of propofol increase, the Observer's Assessment of Alertness/Sedation score was assessed. The following measures were calculated from the electroencephalographic signal: spectral entropy, approximate entropy, Higuchi fractal dimension, Lempel-Ziv complexity, relative beta ratio, and SyncFastSlow measure. Results: The behavior of the electroencephalogram-based measures is highly sensitive to the frequency content of the signal and the dose of remifentanil. The prediction probability with respect to the Observer's Assessment of Alertness/Sedation score of the most discriminative measure, the Higuchi fractal dimension, dropped from 0.90 (electroencephalographic frequency band 6-47 Hz, no remifentanil) to 0.55 when the frequency band was changed to 0.5-19 Hz and to 0.83 when remifentanil concentration was increased to 4 ng/ml. The coeffect of remifentanil on electroencephalographic regularity is bimodal depending on the frequency band of the signal. Conclusions: Cutting off high frequencies from the electroencephalogram and increased remifentanil concentration deteriorate the performance of the electroencephalogram-based entropy/complexity measures as indicators of the depth of propofol sedation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.anes.0000264790.07231.2d

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 79

Metadata

Authors
Ferenets, R., Vanluchene, A., Lipping, T., Heyse, B., & Struys, M. M. R. F.
Venue
Anesthesiology
Published
2007-04-01
Volume
106
Issue
4
Pages
696-706
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2137660391
Cited by
79
References
2
FWCI
6.91
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Behavior of Entropy/Complexity Measures of the Electroencephalogram during Propofol-induced Sedation: Dose-dependent Effects of Remifentanil. https://app.cochat.ai/papers/10.1097/01.anes.0000264790.07231.2d
The paper
Ferenets, R., Vanluchene, A., Lipping, T., Heyse, B., & Struys, M. M. R. F. (2007). Behavior of Entropy/Complexity Measures of the Electroencephalogram during Propofol-induced Sedation: Dose-dependent Effects of Remifentanil. Anesthesiology. https://doi.org/10.1097/01.anes.0000264790.07231.2d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.