The Movement of the Knee Studied by Magnetic Resonance Imaging
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The author's work using magnetic resonance imaging to study the relative movements (the kinematics) of the tibia and femur is reviewed. The description is understood best by reference to comparative anatomy and by dividing the flexion arc into three components. Knee activities take place mainly between 10 degrees and 120 degrees. Over this arc, the articulating surfaces of the femoral condyles are circular in sagittal section and rotate around their center. The medial condyle does not move anteroposteriorly (roll-back does not occur medially). The lateral condyle tends to roll back producing tibial internal rotation with flexion. From full extension to 10 degrees to 30 degrees tibial internal rotation is coupled with flexion. The articulating surfaces medially are a larger radiused anterior femoral facet, which articulates with an upward-sloping tibial facet. Laterally, the femoral condyle rolls forward onto the anterior horn. Flexion beyond 120 degrees only can be achieved passively. Medially, the femur rolls up onto the posterior horn. Laterally, the femur and the posterior horn drop over the posterior tibia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iwaki, H., Pinskerova, V., & Freeman, M. A. R. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b8.0821189 · Cited by 736
Self-citationTibiofemoral movement 2: the loaded and unloaded living knee studied by MRI
Hill, P. F., Vedi, V., Williams, A., Iwaki, H., Pinskerova, V., & Freeman, M. A. R. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b8.0821196 · Cited by 393
Self-citationTibial meniscal dynamics using three-dimensional reconstruction of magnetic resonance images
Thompson, W. O., Thaete, F. L., Fu, F. H., & Dye, S. F. (1991) · The American Journal of Sports Medicine · doi:10.1177/036354659101900302 · Cited by 391
THE MECHANICS OF THE LIGAMENTS AND MENISCI OF THE KNEE JOINT
Brantigan, O. C., & Voshell, A. F. (1941) · Journal of Bone and Joint Surgery · Cited by 381
Geometry and motion of the knee for implant and orthotic design
Kurosawa, H., Walker, P. S., Abe, S., Garg, A., & Hunter, T. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90663-3 · Cited by 292
Tibiofemoral movement 3: full flexion in the living knee studied by MRI
Nakagawa, S., Kadoya, Y., Todo, S., Kobayashi, A., Sakamoto, H., Freeman, M. A. R., & Yamano, Y. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b8.0821199 · Cited by 288
Self-citationMeasurement of the screw-home motion of the knee is sensitive to errors in axis alignment
Piazza, S. J., & Cavanagh, P. R. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00056-7 · Cited by 244
You, B.-M., Siy, P., Anderst, W., & Tashman, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.929617 · Cited by 200
The “Screw-Home” Movement in the Knee-Joint
Hallén, L. G., & Lindahl, O. (1966) · Acta Orthopaedica Scandinavica · doi:10.3109/17453676608989407 · Cited by 190
The shapes of the tibial and femoral articular surfaces in relation to tibiofemoral movement
Martelli, S., & Pinskerová, V. (2002) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.84b4.0840607 · Cited by 119
Cited by
The movement of the normal tibio-femoral joint
Freeman, M. A. R., & Pinskerova, V. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.006 · Cited by 532
Self-citationFeasibility of Using Orthogonal Fluoroscopic Images to Measure In Vivo Joint Kinematics
Li, Wuerz, & DeFrate, L. E. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1691448 · Cited by 192
Roth, J. D., Howell, S. M., & Hull, M. L. (2015) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.n.01256 · Cited by 172
Metadata
- Authors
- Freeman, M. A. R., & Pinskerova, V.
- Venue
- Clinical Orthopaedics & Related Research
- Published
- 2003-05
- Volume
- 410
- Issue
- 410
- Pages
- 35-43
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2045906018
- Cited by
- 187
- References
- 16
- FWCI
- 6.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Movement of the Knee Studied by Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1097/01.blo.0000063598.67412.0d
- The paper
- Freeman, M. A. R., & Pinskerova, V. (2003). The Movement of the Knee Studied by Magnetic Resonance Imaging. Clinical Orthopaedics & Related Research. https://doi.org/10.1097/01.blo.0000063598.67412.0d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.