The DOI matches its Crossref record.
Feasibility of Using Orthogonal Fluoroscopic Images to Measure In Vivo Joint Kinematics
Abstract
Accurately determining in vivo knee kinematics is still a challenge in biomedical engineering. This paper presents an imaging technique using two orthogonal images to measure 6 degree-of-freedom (DOF) knee kinematics during weight-bearing flexion. Using this technique, orthogonal images of the knee were captured using a 3-D fluoroscope at different flexion angles during weight-bearing flexion. The two orthogonal images uniquely characterized the knee position at the specific flexion angle. A virtual fluoroscope was then created in solid modeling software and was used to reproduce the relative positions of the orthogonal images and X-ray sources of the 3-D fluoroscope during the actual imaging procedure. Two virtual cameras in the software were used to represent the X-ray sources. The 3-D computer model of the knee was then introduced into the virtual fluoroscope and was projected onto the orthogonal images by the two virtual cameras. By matching the projections of the knee model to the orthogonal images of the knee obtained during weight-bearing flexion, the knee kinematics in 6 DOF were determined. Using regularly shaped objects with known positions and orientations, this technique was shown to have an accuracy of 0.1 mm and 0.1 deg in determining the positions and orientations of the objects, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gait analysis methods in rehabilitation
Baker, R. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-4 · Cited by 587
Bey, M. J., Zauel, R., Brock, S. K., & Tashman, S. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2206199 · Cited by 300
DeFrate, L. E., Papannagari, R., Gill, T. J., Moses, J. M., Pathare, N. P., & Li, G. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546506287299 · Cited by 272
Self-citationJordan, S. S., DeFrate, L. E., Wook Nha, K., Papannagari, R., Gill, T. J., & Li, G. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546506295941 · Cited by 121
Self-citationWang, C., Xie, S., Li, K., Wang, C., Liu, X., Zhao, L., & Tsai, T.-Y. (2021) · Engineering · doi:10.1016/j.eng.2020.03.016 · Cited by 19
Metadata
- Authors
- Li, Wuerz, & DeFrate, L. E.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2004-04-01
- Volume
- 126
- Issue
- 2
- Pages
- 313-318
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2069275527
- Cited by
- 192
- References
- 0
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Feasibility of Using Orthogonal Fluoroscopic Images to Measure In Vivo Joint Kinematics. https://app.cochat.ai/papers/10.1115/1.1691448
- The paper
- Li, Wuerz, & DeFrate, L. E. (2004). Feasibility of Using Orthogonal Fluoroscopic Images to Measure In Vivo Joint Kinematics. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.1691448
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.