The History and Future of Radiostereometric Analysis
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Roentgen stereophotogrammetry allows one to localize the position of an object in space using roentgen rays. For orthopaedic purposes it was developed 35 years ago by Göran Selvik, and since that time many investigators have refined the radiostereometric calculations and evaluative software. Many uses and mathematical algorithms have been developed, and advancements in computer programs and digital radiography continue to expand its capabilities. Despite these advances, improvements in the technical accuracy and type of kinematic analyses possible have been relatively modest. However, radiostereometric analysis is now easier and less time consuming to use, with a resolution in clinical practice almost equal to what could only previously be obtained under ideal laboratory conditions. The ability to measure skeletal and implant movements with high resolution in vivo images was an important progressive step for the orthopaedic community. Radiostereometric analysis has helped develop new fields in clinical orthopaedic research and continues to improve advancements in orthopaedic health care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three-dimensional object recognition from single two-dimensional images
Lowe, D. G. (1987) · Artificial Intelligence · doi:10.1016/0004-3702(87)90070-1 · Cited by 1,283
Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.
Selvik, G. (1989) · PubMed · Cited by 702
Proceedings of the Society of Photo-optical Instrumentation Engineers
Brown, B. S. (1975) · Optica Acta: International Journal of Optics · doi:10.1080/713819103 · Cited by 659
Karrholm, J., Borssen, B., Lowenhielm, G., & Snorrason, F. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b6.7983118 · Cited by 622 · cited 3×
“The clinical importance of early migration on the risk of later loosening differs depending on prosthetic design, surface finish, and method of fixation.(58) Femoral stems with polished surfaces may show comparatively more distal migration (1–2 mm) almost exclusively inside the cement mantle(6) despite good long-term…”
BackgroundRoentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
Ryd, L., Albrektsson, B., Carlsson, L., Dansgard, F., Herberts, P., Lindstrand, A., Regner, L., & Toksvig-Larsen, S. (1995) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.77b3.7744919 · Cited by 603 · cited 3×
“could be predicted with a sensitivity of 58% and a specificity of 93%.(106) Kärrholm et al(58) found the magnitude of stem subsidence also could be used to predict revision”
BackgroundMethodAccurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
Banks, S. A., & Hodge, W. A. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.495283 · Cited by 596 · cited 1×
“This technique originates from 3-D vision(75,132) and is also used in roentgen fluoroscopic analysis.(12,48,70,110,114,135) For total knee prostheses the use of CAD models sup-”
MethodFacial Growth in Man, Studied with the AID of Metallic Implants
Björk, A. (1955) · Acta Odontologica Scandinavica · doi:10.3109/00016355509028170 · Cited by 571
Guidelines for standardization of radiostereometry (RSA) of implants
Valstar, E. R., Gill, R., Ryd, L., et al. (2005) · Acta Orthopaedica · doi:10.1080/17453670510041574 · Cited by 538 · cited 1×
“Such a protocol will include RSA as part of a standard procedure for implant testing before market release.(126) The value of RSA studies is well accepted by centers that strive to develop RSA systems and”
BackgroundSelf-citationRoentgen stereophotogrammetry: A method for the study of the kinematics of the skeletal system
Selvik, G. (1989) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678909154184 · Cited by 478 · cited 2×
“Selvik further developed Hallert’s method and added three important parts: tantalum pins (later replaced by spheres) to obtain distinct landmarks, calibrated cages with small metallic markers, and data reporting based on the principles of rigid body kinematics.(112) The system enabled an accurate description of rotati…”
BackgroundMethodRoentgen Stereophotogrammetric Analysis
Selvik, G. (1990) · Acta Radiologica · doi:10.1177/028418519003100201 · Cited by 309
Cited by
Additively manufactured porous tantalum implants
Wauthle, R., van der Stok, J., Amin Yavari, S., Van Humbeeck, J., Kruth, J.-P., Zadpoor, A. A., Weinans, H., Mulier, M., & Schrooten, J. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.12.003 · Cited by 417
In silico clinical trials in the orthopedic device industry: from fantasy to reality?
Favre, P., Maquer, G., Henderson, A., Hertig, D., Ciric, D., & Bischoff, J. E. (2021) · Annals of Biomedical Engineering · doi:10.1007/s10439-021-02787-y · Cited by 32
“As an example, early migration evaluated via Roentgen Stereogrammetric Analysis (RSA) two years after surgery is able to identify implants at risk of revision before actual failure, 36 thus shortening the window of clinical observation from 10 years to 2 years.”
Method
Metadata
- Authors
- K??rrholm, J., Gill, R. H. S., & Valstar, E. R.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2006-07
- Volume
- 448
- Pages
- 10-21
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2068135310
- Cited by
- 168
- References
- 40
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.