The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
Abstract
A simple extension of a previously reported object recognition technique has been used to implement a six-degree-of-freedom position/orientation estimator for the measurement of knee replacement motion from two-dimensional (2-D) fluoroscopic images. Computer modeling studies and controlled mechanical tests were performed to assess the accuracy of the technique. The results indicate that knee rotations can be measured with an accuracy of approximately one degree and that sagittal plane translations can be measured with an accuracy of approximately 0.5 mm. The measurement technique is uniquely well suited for performing dynamic kinematic measurements on individuals with knee replacements, and for performing comparative studies among subjects with different designs of knee replacements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Two-Dimensional Signal and Image Processing
Lim, J. S. (1989) · Medical Entomology and Zoology · Cited by 2,561
Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait
Kadaba, M. P., Ramakrishnan, H. K., Wootten, M. E., Gainey, J., Gorton, G., & Cochran, G. V. B. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070611 · Cited by 1,476
Grood, E. S., Stowers, S. F., & Noyes, F. R. (1988) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198870010-00014 · Cited by 672
The influence of total knee-replacement design on walking and stair-climbing.
Andriacchi, T. P., Galante, J. O., & Fermier, R. W. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264090-00008 · Cited by 642
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Tibial meniscal dynamics using three-dimensional reconstruction of magnetic resonance images
Thompson, W. O., Thaete, F. L., Fu, F. H., & Dye, S. F. (1991) · The American Journal of Sports Medicine · doi:10.1177/036354659101900302 · Cited by 391
The envelope of passive knee joint motion
Blankevoort, L., Huiskes, R., & de Lange, A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90280-1 · Cited by 376
Ligament length relationships in the moving knee
Sidles, J. A., Larson, R. V., Garbini, J. L., Downey, D. J., & Matsen, F. A. (1988) · Journal of Orthopaedic Research · doi:10.1002/jor.1100060418 · Cited by 370
Justification of triaxial goniometer for the measurement of joint rotation
Chao, E. Y. S. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90044-5 · Cited by 316
Cited by
A Framework for the in Vivo Pathomechanics of Osteoarthritis at the Knee
Andriacchi, T. P., Mündermann, A., Smith, R. L., Alexander, E. J., Dyrby, C. O., & Koo, S. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000017541.82498.37 · Cited by 1,062
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
Brainerd, E. L., Baier, D. B., Gatesy, S. M., Hedrick, T. L., Metzger, K. A., Gilbert, S. L., & Crisco, J. J. (2010) · Journal of Experimental Zoology Part A: Ecological Genetics and Physiology · doi:10.1002/jez.589 · Cited by 524
A Point Cluster Method for In Vivo Motion Analysis: Applied to a Study of Knee Kinematics
Andriacchi, T. P., Alexander, E. J., Toney, M. K., Dyrby, C., & Sum, J. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834888 · Cited by 495
Mündermann, L., Corazza, S., & Andriacchi, T. P. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-6 · Cited by 387
Metadata
- Authors
- Banks, S. A., & Hodge, W. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1996-06
- Volume
- 43
- Issue
- 6
- Pages
- 638-649
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2102238798
- Cited by
- 596
- References
- 18
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. https://app.cochat.ai/papers/10.1109/10.495283
- The paper
- Banks, S. A., & Hodge, W. A. (1996). Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.495283
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.