Preclinical Evaluation of a Poly (Vinyl Alcohol) Hydrogel Implant as a Replacement for the Nucleus Pulposus
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In Brief Study Design. An in vivo investigation into the safety of a novel hydrogel implant designed to replace the diseased nucleus pulposus. Objectives. To determine the local and systemic safety of this new implant in a nonhuman primate model. Summary of Background Data. A poly (vinyl alcohol) (PVA) hydrogel has been developed as a prosthetic replacement for the diseased nucleus pulposus. Methods. PVA implants were inserted into discectomy defects created in the L3–L4 or L4–L5 intervertebral disc in 20 male baboons. Empty discectomy defects served as a surgical control in 8 additional animals. Routine follow-up evaluations included radiography, magnetic resonance imaging, gross pathology, and histopathology of both local and remote tissues. Results. Insertion of the PVA hydrogel from an anterior direction produced extrusions in 5 animals from the first series of 15 surgeries (33%). A modified surgical technique, involving an anterolateral rather than anterior approach, was used in 5 animals, but the extrusion rate remained high (20%). Despite these surgical complications, the PVA implants were well tolerated over 24 months in vivo, with no evidence of device-related pathology in the adjacent disc tissue, spinal cord, or remote tissues. Conclusion. Implantation of the PVA implant for periods of up to 24 months produced no evidence of local or systemic toxicity. Additional studies are now needed to determine the efficacy of the device in its intended application. Artificial nucleus implants fabricated from a poly (vinyl alco-hol) (PVA) hydrogel were implanted in the lumbar discs of adult baboons for up to 24 months. The implants were well tolerated and there was no evidence of device-related toxicity. Future investigations into the use of the PVA artificial nucleus appear to be justified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biochemical changes in intervertebral disc degeneration
Lyons, G., Eisenstein, S. M., & Sweet, M. B. E. (1981) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(81)90476-1 · Cited by 314 · cited 1×
“As the disc degenerates, proteoglycans are lost, leading to a reduction in the hydration state of the nucleus, from a normal value of 80% to approximately 70%.(4) With a decreasing oncotic pressure, the nucleus is less able to attract water and nutrients in from the endplate, and this in turn predisposes to further di…”
BackgroundGeometrical dimensions of the lower lumbar vertebrae - analysis of data from digitised CT images
Zhou, S., McCarthy, I. D., McGregor, A., Coombs, R., & Hughes, S. P. F. (2000) · European Spine Journal · doi:10.1007/s005860000140 · Cited by 222
Sterile hypopyon secondary to ultrasonic cleaning solution
Richburg, F. A., Reidy, J. J., Apple, D. J., & Olson, R. J. (1986) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(86)80002-5 · Cited by 49 · cited 1×
“Previous studies have noted that a mild host inflammatory response can occur in response to endotoxin or fragments of bacterial cell walls in the absence of viable organisms.(15,16) In this study, some of the instruments were cleaned with Cidex (Cidex; Surgikos, Inc.”
Boelens, J. J., Zaat, S. A. J., Meeldijk, J., & Dankert, J. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(20000615)50:4<546::aid-jbm10>3.0.co;2-y · Cited by 44 · cited 1×
“Previous studies have noted that a mild host inflammatory response can occur in response to endotoxin or fragments of bacterial cell walls in the absence of viable organisms.(15,16) In this study, some of the instruments were cleaned with Cidex (Cidex; Surgikos, Inc.”
Editorial - Identification of Orthopaedic Wear Debris
Bauer, T. W. (1996) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199604000-00001 · Cited by 20
Self-citation
Cited by
Novel chitin and chitosan nanofibers in biomedical applications
Jayakumar, R., Prabaharan, M., Nair, S. V., & Tamura, H. (2010) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.11.001 · Cited by 1,013
A Review: Electrospinning of Biopolymer Nanofibers and their Applications
Schiffman, J. D., & Schauer, C. L. (2008) · Polymer Reviews · doi:10.1080/15583720802022182 · Cited by 820
Chitosan nanoparticles preparation and applications
Divya, K., & Jisha, M. S. (2018) · Environmental Chemistry Letters · doi:10.1007/s10311-017-0670-y · Cited by 703
High strength graphene oxide/polyvinyl alcohol composite hydrogels
Zhang, L., Wang, Z., Xu, C., Li, Y., Gao, J., Wang, W., & Liu, Y. (2011) · Journal of Materials Chemistry · doi:10.1039/c0jm04043f · Cited by 439
Holloway, J. L., Lowman, A. M., & Palmese, G. R. (2013) · Soft Matter · doi:10.1039/c2sm26763b · Cited by 350
Iatridis, J. C., Nicoll, S. B., Michalek, A. J., Walter, B. A., & Gupta, M. S. (2013) · The Spine Journal · doi:10.1016/j.spinee.2012.12.002 · Cited by 313
Mengiardi, B., Schmid, M. R., Boos, N., Pfirrmann, C. W. A., Brunner, F., Elfering, A., & Hodler, J. (2006) · Radiology · doi:10.1148/radiol.2403050820 · Cited by 281
Rahmani Del Bakhshayesh, A., Annabi, N., Khalilov, R., Akbarzadeh, A., Samiei, M., Alizadeh, E., Alizadeh-Ghodsi, M., Davaran, S., & Montaseri, A. (2018) · Artificial Cells, Nanomedicine, and Biotechnology · doi:10.1080/21691401.2017.1349778 · Cited by 250
“Due to poly(vinyl alcohol) (PVA) favourable properties such as nontoxicity, biocompatibility and biodegradability, it was used for a wide variety of the biomedical applications such as bone implants [106] and artificial organs such as skin [107].”
Preparations, properties and applications of chitosan based nanofibers fabricated by electrospinning
Sun, K., & Li, Z. H. (2011) · Express Polymer Letters · doi:10.3144/expresspolymlett.2011.34 · Cited by 249
“Because of its favorable properties such as nontoxicity, biocompatibility and biodegradability, PVA has been used for a variety of biomedical applications such as bone implants as a replacement for the nucleus pulposus [26] and artificial organs [27].”
Su, W.-Y., Chen, Y.-C., & Lin, F.-H. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.037 · Cited by 247
Poly(Vinyl Alcohol) Physical Hydrogels: New Vista on a Long Serving Biomaterial
Alves, M., Jensen, B. E. B., Smith, A. A. A., & Zelikin, A. N. (2011) · Macromolecular Bioscience · doi:10.1002/mabi.201100145 · Cited by 228
An injectable vehicle for nucleus pulposus cell-based therapy
Collin, E. C., Grad, S., Zeugolis, D. I., Vinatier, C. S., Clouet, J. R., Guicheux, J. J., Weiss, P., Alini, M., & Pandit, A. S. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.018 · Cited by 221
Hides, J., Stanton, W., Freke, M., Wilson, S., McMahon, S., & Richardson, C. (2008) · British Journal of Sports Medicine · doi:10.1136/bjsm.2007.044024 · Cited by 214
A Novel Cross‐linked Poly(vinyl alcohol) (PVA) for Vascular Grafts
Chaouat, M., Le Visage, C., Baille, W. E., Escoubet, B., Chaubet, F., Mateescu, M. A., & Letourneur, D. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200701261 · Cited by 204
State of the art composites comprising electrospun fibres coupled with hydrogels: a review
Bosworth, L. A., Turner, L.-A., & Cartmell, S. H. (2013) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2012.10.008 · Cited by 159
Injectable silk fibroin/polyurethane composite hydrogel for nucleus pulposus replacement
Hu, J., Chen, B., Guo, F., Du, J., Gu, P., Lin, X., Yang, W., Zhang, H., Lu, M., Huang, Y., et al. (2012) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-011-4533-y · Cited by 69
Metadata
- Authors
- Allen, M. J., Schoonmaker, J. E., Bauer, T. W., Williams, P. F., Higham, P. A., & Yuan, H. A.
- Venue
- Spine
- Published
- 2004-03
- Volume
- 29
- Issue
- 5
- Pages
- 515-523
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W1964652258
- Cited by
- 166
- References
- 5
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.