CoChat

Kinematics of the Upper Cervical Spine in Rotation: In Vivo Three-Dimensional Analysis

Ishii, Takahiro, Mukai, Yoshihiro, Hosono, Noboru, Sakaura, Hironobu, Nakajima, Yoshikazu, Sato, Yoshinobu, Sugamoto, Kazuomi, Yoshikawa, Hideki · 2004 · Spine
Cited by 229

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

STUDY DESIGN: Kinematics of the upper cervical spine during head rotation were investigated using three-dimensional magnetic resonance imaging (MRI) in healthy volunteers. OBJECTIVES: To demonstrate in vivo intervertebral coupled motions of the upper cervical spine. SUMMARY OF BACKGROUND DATA: Although various in vivo and in vitro studies have identified the normal movement patterns of the upper cervical spine, no previous studies have accurately analyzed in vivo three-dimensional intervertebral motions of the upper cervical spine during head rotation. METHODS: Fifteen healthy volunteers underwent three-dimensional MRI of the upper cervical spine using a 1.0-T imager in progressive 15 degrees steps during head rotation. Segmented three-dimensional MRIs of each vertebra in the neutral position were superimposed over images taken at other positions, using voxel-based registration. Relative motions between occiput (Oc) and atlas (C1) and between C1 and axis (C2) were measured and described with 6 degrees of freedom by rigid body Euler angles and translations. RESULTS: Mean (+/- SD) maximum angles of axial rotation in Oc-C1 and C1-C2 were 1.7 +/- 1.5 degrees and 36.2 +/- 4.5 degrees to each side, respectively. Increases in angle of axial rotation in C1-C2 became smaller with increased head rotation, indicating axial rotation in C1-C2 displayed nonlinear motion. Coupled lateral bending with axial rotation was observed in the direction opposition to that of axial rotation in Oc-C1 (mean, 4.1 +/- 1.4 degrees) and C1-C2 (mean, 3.8 +/- 3.0 degrees). Coupled extension with axial rotation occurred at both C0-C1 (mean, 13.3 +/- 4.9 degrees) and C1-C2 (mean, 6.9 +/- 3.0 degrees). CONCLUSIONS: We developed an innovative in vivo three-dimensional motion analysis system using three-dimensional MRI. In vivo coupled motions of the upper cervical spine investigated using this system supported the results of the previous in vitro study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.brs.0000116998.55056.3c

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 229

Metadata

Authors
Ishii, T., Mukai, Y., Hosono, N., Sakaura, H., Nakajima, Y., Sato, Y., Sugamoto, K., & Yoshikawa, H.
Venue
Spine
Published
2004-04
Volume
29
Issue
7
Pages
E139-E144
ISSN
0362-2436 (ISSN-L)
OpenAlex
W1995885958
Cited by
229
References
13
FWCI
8.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Kinematics of the Upper Cervical Spine in Rotation: In Vivo Three-Dimensional Analysis. https://app.cochat.ai/papers/10.1097/01.brs.0000116998.55056.3c
The paper
Ishii, T., Mukai, Y., Hosono, N., Sakaura, H., Nakajima, Y., Sato, Y., Sugamoto, K., & Yoshikawa, H. (2004). Kinematics of the Upper Cervical Spine in Rotation: In Vivo Three-Dimensional Analysis. Spine. https://doi.org/10.1097/01.brs.0000116998.55056.3c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.