Individual characteristics of reliable lumbar coupling motions
Abstract
Introduction Coupling motions (CMs) are the motions occurring in different directions around the primary motion. As low back pain (LBP) is known to be associated with lumbar CMs, some studies measured lumbar CMs using the microelectromechanical system inertial measurement unit (MEMS-IMU) because of its low cost and small size. This study aimed to examine the reliability of lumbar CM measurements using the MEMS-IMU and to classify the individual characteristics of lumbar CMs.Methods MEMS-IMUs were attached to the two lumbar points (L₁, L₅) of 19 male volunteers (age, 24.3 ± 1.2 years). Following an instructional video and audio recording, they conducted the six lumbar movements three times: flexion and extension, left and right lateral bending, and left and right rotation. The six lumbar movements were repeated after 1 h. Raw data were transformed into angle data using MATLAB. Intraclass correlation coefficients (ICCs) were calculated to evaluate intratest repeatability and test-retest reliability. Finally, angle data were analyzed to examine whether individual characteristics of lumbar CMs could be identified.Results Lumbar CM measurements showed fair to good or excellent intratest repeatability and test-retest reliability, ranging from 0.669 to 0.997 of the ICCs. All lumbar CMs could be categorized into six types, and flexion and extension CMs were more prominent than other CMs.Conclusions Lumbar CM measurements obtained using the MEMS-IMU are reliable, and identifying the individual variations of lumbar CMs may be helpful for alleviating chronic or recurrent LBP.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Trunk reliability results are consistent and demonstrate good to excellent intra-rater reliability (ICC ≥0.8 except coronal plane fair to excellent 0.67 to 0.93).
“Results from these three studies are consistent and demonstrate good to excellent intra-rater reliability (ICC ≥ 0.8 except for coronal plane which is fair to excellent (0.67 to 0.93)) [46,66,68].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [68]
Cites
Wu, G., van der Helm, F. C. T., Veeger, H. E. J., Makhsous, M., Roy, P. V., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K. J., Wang, X., et al. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,569 · see citing works
Oswestry Low Back Pain Disability Questionnaire
Fairbank, J. C. T., Couper, J., Davies, J. B., & O'Brien, J. P. (2006) · Springer eBooks · doi:10.1007/978-3-540-29805-2_3023 · Cited by 3,954 · see citing works
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., DʼLima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,249 · see citing works
The Roland–Morris Disability Questionnaire and the Oswestry Disability Questionnaire
Roland, M. O., & Fairbank, J. C. T. (2000) · Spine · doi:10.1097/00007632-200012150-00006 · Cited by 1,913 · see citing works
Validation of the Korean Version of the Oswestry Disability Index
Kim, D.-Y., Lee, S.-H., Lee, H.-Y., Lee, H., Chang, S.-B., Chung, S.-K., & Kim, H.-J. (2005) · Spine · doi:10.1097/01.brs.0000157172.00635.3a · Cited by 301 · see citing works
Self-citationNACHEMSON, A. K., & ELFSTRÖM, G. (1970) · PubMed · Cited by 289 · see citing works
Acupuncture for Chronic Low Back Pain
Berman, B. M., Langevin, H. M., Witt, C. M., & Dubner, R. (2010) · New England Journal of Medicine · doi:10.1056/nejmct0806114 · Cited by 273 · see citing works
Pinsault, N., & Vuillerme, N. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.08.003 · Cited by 231 · see citing works
Kinematics of the Upper Cervical Spine in Rotation
Ishii, T. M., Mukai, Y., Hosono, N., et al. (2004) · Spine · doi:10.1097/01.brs.0000116998.55056.3c · Cited by 229 · see citing works
Intravital dynamic pressure measurements in lumbar discs
NACHEMSON, A. K. (1970) · Medical Entomology and Zoology · Cited by 194 · see citing works
Intratester and intertester reliability of the cervical range of motion device.
CAPUANO-PUCCI, D. L., Rheault, W., Aukai, J., et al. (1991) · PubMed · Cited by 174 · see citing works
The Mechanism of the Lumbar Spine
Gracovetsky, S., Farfan, H. F., & Lamy, C. (1981) · Spine · doi:10.1097/00007632-198105000-00007 · Cited by 163 · see citing works
Trunk posture monitoring with inertial sensors
Wong, W. Y., & Wong, M. S. (2008) · European Spine Journal · doi:10.1007/s00586-008-0586-0 · Cited by 155 · see citing works
Relationship between the movements of the lumbar spine and hip
Lee, R., & Wong, T. K. T. (2002) · Human Movement Science · doi:10.1016/s0167-9457(02)00117-3 · Cited by 154 · see citing works
Movement System Impairment Syndromes of the Extremities, Cervical and Thoracic Spines
Sahrmann, S. A. (2010) · Cited by 146 · see citing works
Feasibility of using inertial sensors to assess human movement
Saber-Sheikh, K., Bryant, E. C., Glazzard, C., Hamel, A., & Lee, R. (2009) · Manual Therapy · doi:10.1016/j.math.2009.05.009 · Cited by 128 · see citing works
A Database for Estimating Normal Spinal Motion Derived From Noninvasive Measurements
Gracovetsky, S., Newman, N. M., Pawlowsky, M., Lanzo, V. F., Davey, B., & Robinson, L. (1995) · Spine · doi:10.1097/00007632-199505000-00010 · Cited by 120 · see citing works
Herp, G. V., Rowe, P. J., Salter, P., & Paul, J. P. (2000) · Lara D. Veeken · doi:10.1093/rheumatology/39.12.1337 · Cited by 114 · see citing works
Kinematics of the Subaxial Cervical Spine in Rotation In Vivo Three-Dimensional Analysis
Ishii, T. M., Mukai, Y., Hosono, N., et al. (2004) · Spine · doi:10.1097/01.brs.0000147806.31675.6b · Cited by 92 · see citing works
Ha, T. H., Saber-Sheikh, K., Moore, A. P., & Jones, M. P. (2012) · Manual Therapy · doi:10.1016/j.math.2012.04.003 · Cited by 81 · see citing works
Do inertial sensors represent a viable method to reliably measure cervical spine range of motion?
Theobald, P. S., Jones, M. D., & Williams, J. M. (2011) · Manual Therapy · doi:10.1016/j.math.2011.06.007 · Cited by 74 · see citing works
Movement system impairment syndromes of the extremities, cervical and thoracic spines
Bougie, T. L. (2012) · Manual Therapy · doi:10.1016/j.math.2011.12.008 · Cited by 73 · see citing works
Sørensen, P. H., Bendix, T., Manniche, C., Korsholm, L., Lemvigh, D., & Indahl, A. (2010) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-11-212 · Cited by 70 · see citing works
MEASUREMENT OF THE RANGE AND COUPLED MOVEMENTS OBSERVED IN THE LUMBAR SPINE
RUSSELL, P., PEARCY, M. J., & UNSWORTH, A. (1993) · Rheumatology · doi:10.1093/rheumatology/32.6.490 · Cited by 61 · see citing works
Three-dimensional kinematics of the human back
Hindle, R. J., Pearcy, M. J., Cross, A. T., & Miller, D. H. T. (1990) · Clinical Biomechanics · doi:10.1016/0268-0033(90)90005-q · Cited by 55 · see citing works
Kim, H., Shin, S.-H., Kim, J.-K., Park, Y.-J., Oh, H.-S., & Park, Y.-B. (2013) · Evidence-Based Complementary and Alternative Medicine · doi:10.1155/2013/570428 · Cited by 26 · see citing works
Self-citationHof, A. L., Koerhuis, C. L., & Winters, J. C. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00012-2 · Cited by 22 · see citing works
Feipel, V., Salvia, P., Rondelet, B., et al. (2001) · Dépôt institutionnel de l'Université libre de Bruxelles (Université Libre de Bruxelles) · Cited by 7 · see citing works
Jung, J.-Y., Yang, Y., Won, Y., et al. (2011) · Journal of the Institute of Electronics Engineers of Korea · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309 · see citing works
- Authors
- Yun, W.-S., Kim, H., Ahn, J. H., Park, Y.-B., & Park, Y.-J.
- Affiliations
- Kyung Hee University (KR)
- Corresponding author
- Park, Young-Bae
- Park, Young-Jae
- Venue
- European Spine Journal
- Published
- 2015-06-24
- Volume
- 24
- Issue
- 9
- Pages
- 1917-1925
- ISSN
- 0940-6719 (ISSN-L)
- 1432-0932
- OpenAlex
- W2161015456
- Cited by
- 16
- References
- 29
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 4 · 2022: 3 · 2020: 1 · 2019: 3 · 2018: 1 · 2016: 1
- FWCI
- 0.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Spine Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pharmacology › Musculoskeletal pain and rehabilitation
- Health Sciences › Medicine › Pathology and Forensic Medicine › Spine and Intervertebral Disc Pathology
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Keywords
- low back pain, MEMS inertial measurement unit, test-retest reliability, intraclass correlation coefficient, lumbar flexion and extension, lateral bending, lumbar rotation, interindividual variability, lumbar kinematics
- MeSH terms
- Adult, Humans, Lumbar Vertebrae, Male, Movement, Rotation, Reproducibility of Results, Range of Motion, Articular, Low Back Pain, Arthrometry, Articular, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review