Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record.

Tissue-Engineered Composites of Anulus Fibrosus and Nucleus Pulposus for Intervertebral Disc Replacement

Mizuno, Hirokazu, Roy, Amit K., Vacanti, Charles A., Kojima, Koji, Ueda, Minoru, Bonassar, Lawrence J.·2004·Spine

Abstract

In Brief Study Design. By the technique of tissue engineering, composite intervertebral disc implants were fabricated as novel materials for disc replacement, implanted into athymic mice, and removed at times up to 12 weeks. Objectives. The goal of this study was to construct composite intervertebral disc structures consisting of anulus fibrosus cells and nucleus pulposus cells seeded on polyglycolic acid and calcium alginate matrices, respectively. Summary of Background Data. Previous work has documented the growth of anulus fibrosus cells on collagen matrices and nucleus pulposus cells cultured on multiple matrices, but there is no documentation of composite disc implants. Methods. Lumbar intervertebral discs were harvested from sheep spine, and the nucleus pulposus was separated from surrounding anulus fibrosus. Each tissue was digested in collagenase type II. After 3 weeks in culture, cells were seeded into implants. The shape of the anulus fibrosus scaffold was fabricated from polyglycolic acid and polylactic acid, and anulus fibrosus cells were pipetted onto the scaffold and allowed to attach for 1 day. Nucleus pulposus cells were suspended in 2% alginate and injected into the center of the anulus fibrosus. The disc implants were placed in the subcutaneous space of the dorsum of athymic mice and harvested at 4, 8, and 12 weeks. At each time point, 4 samples were stored in −70 C for collagen typing and analysis of proteoglycan, hydroxyproline, and DNA. Other samples were fixed in 10% formalin for Safranin-O staining. Results. The gross morphology and histology of engineered discs strongly resembled those of native intervertebral discs. Biochemical markers of matrix synthesis were present, increasing with time, and were similar to native tissue at 12 weeks. Tissue-engineered anulus fibrosus was rich in type I collagen but nucleus pulposus contained type II collagen, similar to the native disc. Conclusion. These results demonstrate the feasibility of creating a composite intervertebral disc with both anulusfibrosus and nucleus pulposus for clinical applications. This study describes the generation of composite intervertebral discs consisting of tissue-engineered anulus fibrosus and nucleus pulposus implanted subcutaneously into athymic mice for up to 12 weeks. Implants exhibited excellent shape retention, with distinct anulus fibrosus and nucleus pulposus zones that integrated with time. Histologic and biochemical features of engineered intervertebral discs were similar to native tissue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.brs.0000128264.46510.27

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 238

Metadata

Authors
Mizuno, H., Roy, A. K., Vacanti, C. A., Kojima, K., Ueda, M., & Bonassar, L. J.
Venue
Spine
Published
2004-06
Volume
29
Issue
12
Pages
1290-1297
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2169539463
Cited by
238
References
0
FWCI
7.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tissue-Engineered Composites of Anulus Fibrosus and Nucleus Pulposus for Intervertebral Disc Replacement. https://app.cochat.ai/papers/10.1097/01.brs.0000128264.46510.27
The paper
Mizuno, H., Roy, A. K., Vacanti, C. A., Kojima, K., Ueda, M., & Bonassar, L. J. (2004). Tissue-Engineered Composites of Anulus Fibrosus and Nucleus Pulposus for Intervertebral Disc Replacement. Spine. https://doi.org/10.1097/01.brs.0000128264.46510.27

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.