The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Accuracy of Computer-Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis
Abstract
STUDY DESIGN: A computer-assisted planning and visualization system (the Orthopaedic Surgery Planning System) was tested for pedicle screw insertion in vivo. OBJECTIVES: To evaluate the system's applicability for regular intraoperative use and its accuracy for pedicle screw placement in vivo. SUMMARY OF BACKGROUND DATA: Pedicle screw placement poses considerable anatomic and biomechanical risks. The reported rates of screw misplacement with conventional insertion techniques are unacceptably high. It previously has been shown in vitro that computer assistance offers the potential to decrease the number of screws perforating the pedicular cortex. METHODS: The accuracy of 162 pedicle screws inserted with the Orthopaedic Surgery Planning System was assessed by means of postoperative computed tomography evaluation. Reconstructions of the horizontal, frontal, and sagittal planes were analyzed. Cortex perforations were graded in steps of 2 mm. RESULTS: The cortex was perforated in 2.7% of pedicles. Complete preoperative computed tomography scanning of the levels to be operated on is essential to allow for a precise image reconstruction. Initial difficulties in applying the system contribute to the malplacements. A learning curve for general handling of the Orthopaedic Surgery Planning System was observed. CONCLUSIONS: The system provides a safe and reproducible technique for pedicle screw insertion. Other applications in the field of spine surgery are under evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy of Pedicular Screw Placement In Vivo
GERTZBEIN, S. D., & ROBBINS, S. E. (1990) · Spine · doi:10.1097/00007632-199001000-00004 · Cited by 1,381
Internal Fixation of the Lumbar Spine with Pedicle Screw Plating
ROY-CAMILLE, R., SAILLANT, G., & MAZEL, C. (1986) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198602000-00003 · Cited by 768
A Prospective, Randomized Study of Lumbar Fusion: Priliminary Results
Zdeblick, T. A. (1993) · Spine · doi:10.1097/00007632-199306150-00006 · Cited by 766
Esses, S. I., Sachs, B. L., & Dreyzin, V. (1993) · Spine · doi:10.1097/00007632-199311000-00015 · Cited by 706
WEINSTEIN, J. N., SPRATT, K. F., SPENGLER, D., BRICK, C., & REID, S. (1988) · Spine · doi:10.1097/00007632-198809000-00008 · Cited by 532
Complications of Lumbar Spinal Fusion with Transpedicular Instrumentation
Davne, S. H., & Myers, D. L. (1992) · Spine · doi:10.1097/00007632-199206001-00021 · Cited by 248
Biomechanics of Thoracolumbar Spinal Fixation: A Review
KRAG, M. H. (1991) · Spine · doi:10.1097/00007632-199103001-00014 · Cited by 212
Image-Guided Insertion of Transpedicular Screws: A Laboratory Set-Up
Nolte, L.-P., Zamorano, L. J., Jiang, Z., Wang, Q., Langlotz, F., & Berlemann, U. (1995) · Spine · doi:10.1097/00007632-199502001-00016 · Cited by 197
Self-citationLavallé, S., Sautot, P., Troccaz, J., Cinquin, P., & Merloz, P. (1995) · Journal of Image Guided Surgery · Cited by 163
Clinical evaluation of a system for precision enhancement in spine surgery
Nolte, L.-P., Zamorano, L., Visarius, H., Berlemann, U., Langlotz, F., Arm, E., & Schwarzenbach, O. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)00004-5 · Cited by 141
Self-citation
Cited by
Free Hand Pedicle Screw Placement in the Thoracic Spine: Is it Safe?
Kim, Y. J., Lenke, L. G., Bridwell, K. H., Cho, Y. S., & Riew, K. D. (2004) · Spine · doi:10.1097/01.brs.0000109983.12113.9b · Cited by 706
Amiot, L.-P., Lang, K., Putzier, M., Zippel, H., & Labelle, H. (2000) · Spine · doi:10.1097/00007632-200003010-00012 · Cited by 450
Mason, A., Paulsen, R., Babuska, J. M., Rajpal, S., Burneikiene, S., Nelson, E. L., & Villavicencio, A. T. (2014) · Journal of Neurosurgery: Spine · doi:10.3171/2013.11.spine13413 · Cited by 384
Rajasekaran, S., Vidyadhara, S., Ramesh, P., & Shetty, A. P. (2007) · Spine · doi:10.1097/01.brs.0000252094.64857.ab · Cited by 358
Navigation and Robotics in Spinal Surgery: Where Are We Now?
Overley, S. C., Cho, S. K., Mehta, A. I., & Arnold, P. M. (2017) · Neurosurgery · doi:10.1093/neuros/nyw077 · Cited by 327
Metadata
- Authors
- Schwarzenbach, O., Berlemann, U., Jost, B., Visarius, H., Arm, E., Langlotz, F., Nolte, L.-P., & Ozdoba, C.
- Venue
- Spine
- Published
- 1997-02
- Volume
- 22
- Issue
- 4
- Pages
- 452-458
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2315757648
- Cited by
- 284
- References
- 12
- FWCI
- 14.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Computer-Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis. https://app.cochat.ai/papers/10.1097/00007632-199702150-00020
- The paper
- Schwarzenbach, O., Berlemann, U., Jost, B., Visarius, H., Arm, E., Langlotz, F., Nolte, L.-P., & Ozdoba, C. (1997). Accuracy of Computer-Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis. Spine. https://doi.org/10.1097/00007632-199702150-00020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.