Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 186

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Adaptation to the Intensive Care Environment (ATICE): Development and validation of a new sedation assessment instrument

De Jonghe, Bernard, Cook, Deborah, Griffith, Lauren, Appere-de-Vecchi, Corinne, Guyatt, Gordon, Théron, Valérie, Vagnerre, Annick, Outin, Hervé·2003·Critical Care Medicine

Abstract

OBJECTIVE: To develop a valid, reliable, and responsive bedside instrument assessing Adaptation to the Intensive Care Environment (ATICE) in mechanically ventilated adult intensive care unit (ICU) patients. DESIGN: Instrument development and prospective clinimetric evaluation. SETTING: University-affiliated medical ICU. PATIENTS: Consecutive patients with expected mechanical ventilation of >/=12 hrs. INTERVENTIONS: Administration of ATICE. MEASUREMENTS AND MAIN RESULTS: Item generation for the ATICE involved focus groups and literature review. The ATICE consists of five items: Awakeness and Comprehension combined in a Consciousness domain, and Calmness, Ventilator Synchrony, and Face Relaxation combined in a Tolerance domain. Clinical sensibility of the ATICE assessed by ten ICU physicians and 20 ICU nurses not involved in the development of the ATICE was rated highly (median values 5-7 on a 7-point scale). The ATICE was administered to 80 patients during a total of 152 assessments. Each assessment was performed by three raters (ICU physician, ICU nurse, research nurse), concomitantly with independent scoring of four scales (Ramsay Scale, Riker Scale, Glasgow Coma Scale, and Comfort Scale) and six visual analog scales. Internal consistency was high, as reflected by Cronbach's alpha for the Consciousness and Tolerance domains of .87 and .67, respectively. Intraclass correlation coefficients for the Consciousness and the Tolerance domains ranged from .92 to .99, indicating high interrater reliability. Cross-sectional and longitudinal validity was confirmed for the overall ATICE and the Consciousness and Tolerance domains, as reflected by strong correlations between ATICE and the relevant items or domains of the Ramsay Scale, Riker Scale, Glasgow Coma Scale, Comfort Scale, each of the visual analog scales, and the amounts of sedatives and analgesics administered. CONCLUSIONS: The ATICE measures the adaptation of mechanically ventilated patients to the ICU environment. After rigorous multidisciplinary development, we demonstrated high reliability, validity, and responsiveness of this instrument.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000084850.16444.94

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 186

Metadata

Authors
De Jonghe, B., Cook, D., Griffith, L., Appere-de-Vecchi, C., Guyatt, G., Théron, V., Vagnerre, A., & Outin, H.
Venue
Critical Care Medicine
Published
2003-09
Volume
31
Issue
9
Pages
2344-2354
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2023727587
Cited by
186
References
6
FWCI
9.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adaptation to the Intensive Care Environment (ATICE): Development and validation of a new sedation assessment instrument. https://app.cochat.ai/papers/10.1097/01.ccm.0000084850.16444.94
The paper
De Jonghe, B., Cook, D., Griffith, L., Appere-de-Vecchi, C., Guyatt, G., Théron, V., Vagnerre, A., & Outin, H. (2003). Adaptation to the Intensive Care Environment (ATICE): Development and validation of a new sedation assessment instrument. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000084850.16444.94

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.