Independent Effects of Etiology of Failure and Time to Reintubation on Outcome for Patients Failing Extubation
Abstract
Patients requiring reintubation after failed extubation have a poor prognosis, with hospital mortality exceeding 30 to 40%, though the reason remains unclear. To examine the impact of etiology of extubation failure and time to reintubation on hospital outcome, we performed a post hoc analysis of prospectively gathered data on 74 MICU patients (47 men, 27 women), 64 +/- 2 yr of age who required reintubation within 72 h of extubation. Cause for reintubation was classified as airway (upper airway obstruction, 11; aspiration/excess pulmonary secretions, 12) or nonairway (respiratory failure, 21; congestive heart failure, 17; encephalopathy, 7; other, 6). The duration of mechanical ventilation prior to extubation was 139 +/- 19 h, and the median time to reintubation was 21 h. Thirty-one of 74 patients (42%) died, with mortality highest for patients failing from nonairway etiologies (27/51, 53% versus 4/23, 17%; p < 0.01). Patients failing from an airway cause tended to be reintubated earlier (21 +/- 4 versus 31 +/- 3 h, p = 0.07). Mortality increased with longer duration of time from extubation to reintubation (<= 12 h, 6/25 versus > 12 h, 25/49; p < 0.05). With multiple logistic regression, both cause for extubation failure and time to reintubation were independently associated with hospital mortality. In conclusion, etiology of extubation failure and time to reintubation are independent predictors of outcome in reintubated MICU patients. The high mortality for those reintubated for nonairway problems indicate that efforts should be preferentially focused on identifying these patients. The effect of time to reintubation suggests that identification of patients early after extubation and timely reinstitution of ventilatory support has the potential to reduce the increased mortality associated with extubation failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Failed Extubation on the Outcome of Mechanical Ventilation
Epstein, S. K., Ciubotaru, R. L., & Wong, J. B. (1997) · Chest · doi:10.1378/chest.112.1.186 · Cited by 892
Self-citationExtubation Outcome after Spontaneous Breathing Trials with T-Tube or Pressure Support Ventilation
ESTEBAN, A., ALÍA, I., GORDO, F., FERNÁNDEZ, R., SOLSONA, J. F., VALLVERDÚ, I., MACÍAS, S., ALLEGUE, J. M., BLANCO, J., CARRIEDO, D., et al. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.2.9610109 · Cited by 795
Re-intubation increases the risk of nosocomial pneumonia in patients needing mechanical ventilation.
Torres, A., Gatell, J. M., Aznar, E., el-Ebiary, M., Puig de la Bellacasa, J., González, J., Ferrer, M., & Rodriguez-Roisin, R. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.1.7599812 · Cited by 696
Schwartz, D. E., Matthay, M. A., & Cohen, N. H. (1995) · Anesthesiology · doi:10.1097/00000542-199502000-00007 · Cited by 676
Patient Selection for Clinical Investigation of Ventilator-Associated Pneumonia
Pingleton, S. K., Fagon, J.-Y., & Leeper, K. V. (1992) · Chest · doi:10.1378/chest.102.5_supplement_1.553s · Cited by 253
Rapid Shallow Breathing (Frequency-Tidal Volume Ratio) Did Not Predict Extubation Outcome
Lee, K. H., Hui, K. P., Chan, T. B., Tan, W. C., & Lim, T. K. (1994) · Chest · doi:10.1378/chest.105.2.540 · Cited by 208
Cited by
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support
MacIntyre, N. R. (2001) · Chest · doi:10.1378/chest.120.6_suppl.375s · Cited by 1,240
The impact of delirium in the intensive care unit on hospital length of stay
Ely, E., Gautam, S., Margolin, R., Francis, J., May, L., Speroff, T., Truman, B., Dittus, R., Bernard, G., & Inouye, S. (2001) · Intensive Care Medicine · doi:10.1007/s00134-001-1132-2 · Cited by 1,038
Noninvasive Positive-Pressure Ventilation for Respiratory Failure after Extubation
Esteban, A., Frutos-Vivar, F., Ferguson, N. D., Arabi, Y., Apezteguía, C., González, M., Epstein, S. K., Hill, N. S., Nava, S., Soares, M.-A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032736 · Cited by 894
Self-citationEpidemiology of Weaning Outcome according to a New Definition. The WIND Study
Béduneau, G., Pham, T., Schortgen, F., Piquilloud, L., Zogheib, E., Jonas, M., Grelon, F., Runge, I., Terzi, N., Grangé, S., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201602-0320oc · Cited by 599
Metadata
- Authors
- EPSTEIN, S. K., & CIUBOTARU, R. L.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-08-01
- Volume
- 158
- Issue
- 2
- Pages
- 489-493
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2157128666
- Cited by
- 598
- References
- 6
- FWCI
- 10.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Independent Effects of Etiology of Failure and Time to Reintubation on Outcome for Patients Failing Extubation. https://app.cochat.ai/papers/10.1164/ajrccm.158.2.9711045
- The paper
- EPSTEIN, S. K., & CIUBOTARU, R. L. (1998). Independent Effects of Etiology of Failure and Time to Reintubation on Outcome for Patients Failing Extubation. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.158.2.9711045
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.