The DOI matches its Crossref record.
Effect of Unplanned Extubation on Outcome of Mechanical Ventilation
Abstract
Unplanned extubation is a major complication of translaryngeal intubation, but its impact on mortality, duration of mechanical ventilation (MV), length of intensive care unit (ICU) and hospital stay, and need for ongoing hospital care has not been adequately defined. We performed a case-control study in a tertiary-care medical ICU, comparing 75 patients with unplanned extubation and 150 controls matched for Acute Physiology and Chronic Health Evaluation II score, presence of comorbid conditions, age, indication for MV, and sex. Forty-two (56%) patients required reintubation after unplanned extubation (74% immediately, 86% within 12 h). Thirty-three (44%) unplanned extubations occurred during weaning trials, and 30% of these patients needed reintubation (failed unplanned extubation). In contrast, 76% of patients with unplanned extubation occurring during ventilatory support required reintubation. Although mortality was similar to that of controls (failed unplanned extubation 40%, versus control 31%, p > 0.2), patients with failed unplanned extubation had a significantly longer duration of MV (19 versus 11 d, p < 0.01), longer stay in the ICU (21 versus 14 d, p < 0.05), and longer hospital stay (30 versus 21 d, p < 0.01), and survivors were more likely to require chronic care (64% versus 24%, p < 0.001). Successfully tolerated unplanned extubation was associated with a reduction in time from beginning of weaning to extubation (0.9 versus 2.0 d, p = 0.06), but with no difference in overall duration of MV, mortality, discharge location, ICU, or hospital stay as compared with these measures for controls. We conclude that unplanned extubation is not associated with increased mortality when compared with that of matched controls, although it does result in prolonged MV, longer ICU and hospital stay, and increased need for chronic care. These effects are due exclusively to patients who fail to tolerate unplanned extubation. Although successfully tolerated unplanned extubation decreased the duration of weaning trials, it had no other measurable beneficial impact on outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Outcomes of extubation failure in medical intensive care unit patients*
Thille, A. W., Harrois, A., Schortgen, F., Brun-Buisson, C., & Brochard, L. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182282a5a · Cited by 540
Extubation failure in pediatric intensive care: A multiple-center study of risk factors and outcomes
Kurachek, S. C., Newth, C. J., Quasney, M. W., Rice, T., Sachdeva, R. C., Patel, N. R., Takano, J., Easterling, L., Scanlon, M., Musa, N., et al. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000094228.90557.85 · Cited by 311
Epstein, S. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1268-8 · Cited by 288
Self-citationValentin, A., Capuzzo, M., Guidet, B., Moreno, R. P., Dolanski, L., Bauer, P., & Metnitz, P. G. H. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0290-7 · Cited by 272
Metadata
- Authors
- EPSTEIN, S. K., NEVINS, M. L., & CHUNG, J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-06-01
- Volume
- 161
- Issue
- 6
- Pages
- 1912-1916
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2145566510
- Cited by
- 219
- References
- 0
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Unplanned Extubation on Outcome of Mechanical Ventilation. https://app.cochat.ai/papers/10.1164/ajrccm.161.6.9908068
- The paper
- EPSTEIN, S. K., NEVINS, M. L., & CHUNG, J. (2000). Effect of Unplanned Extubation on Outcome of Mechanical Ventilation. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.161.6.9908068
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.