The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Treatment of fever in the neurologic intensive care unit with a catheter-based heat exchange system
Abstract
CONTEXT: Elevated temperature worsens injury in experimental focal and global ischemia and brain trauma. Fever is common in patients with acute neurologic illness and independently predicts poor outcome. Conventional means of treating fever are not very effective in this population. OBJECTIVE: To study the effectiveness of a catheter-based heat exchange system in reducing elevated temperatures in critically ill neurologic and neurosurgical patients. DESIGN, INTERVENTION, SETTING, AND POPULATION: This was a prospective randomized, non-blinded trial that compared conventional treatment of fever (acetaminophen and cooling blankets) with conventional treatment plus an intravascular catheter-based heat exchange system (Alsius, Irvine, CA). Patients admitted to one of 13 neurologic intensive care units in academic medical centers were eligible if they a) suffered subarachnoid hemorrhage, intracerebral hemorrhage, ischemic infarction, or traumatic brain injury; b) had a temperature >38 degrees C on two occasions or for >4 continuous hrs; and c) required central venous access. MAIN OUTCOME MEASURE: The fever burden (area under the curve >38 degrees C) for 72 hrs was compared in an intention to treat analysis. Safety of the catheter system was monitored. RESULTS: A total of 296 patients were enrolled over 20 months. Forty-one percent had subarachnoid hemorrhage, 24% had traumatic brain injury, 23% had intracerebral hemorrhage, and 13% had ischemic stroke. The groups were matched in terms of age, body mass index, sex, and Glasgow Coma Scale score distribution. Fever burden was 7.92 vs. 2.87 degrees C-hrs in the conventional group and catheter groups, respectively (64% reduction, p <.01). There was no higher rate of infection or the use of sedatives, narcotics, or antibiotics in the catheter group. The catheter did not significantly increase risk to the patient beyond that of a central catheter. CONCLUSIONS: The addition of this catheter-based cooling system to conventional management significantly improves fever reduction in neurologic intensive care unit patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dippel, D. W. J., van Breda, E. J., van Gemert, H. M. A., van der Worp, H. B., Meijer, R. J., Kappelle, L. J., & Koudstaal, P. J. (2001) · Stroke · doi:10.1161/01.str.32.7.1607 · Cited by 149
Cited by
Peberdy, M. A., Callaway, C. W., Neumar, R. W., Geocadin, R. G., Zimmerman, J. L., Donnino, M., Gabrielli, A., Silvers, S. M., Zaritsky, A. L., Merchant, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971002 · Cited by 2,522
Diringer, M. N., Bleck, T. P., Claude Hemphill, J., Menon, D., Shutter, L., Vespa, P., Bruder, N., Connolly, E. S., Citerio, G., Gress, D., et al. (2011) · Neurocritical Care · doi:10.1007/s12028-011-9605-9 · Cited by 1,121
Self-citationSteiner, T., Salman, R. A.-S., Beer, R., Christensen, H., Cordonnier, C., Csiba, L., Forsting, M., Harnof, S., Klijn, C. J. M., Krieger, D., et al. (2014) · International Journal of Stroke · doi:10.1111/ijs.12309 · Cited by 813
Neuroprotection for ischemic stroke: Past, present and future
Ginsberg, M. D. (2008) · Neuropharmacology · doi:10.1016/j.neuropharm.2007.12.007 · Cited by 779
Temperature Monitoring and Perioperative Thermoregulation
Sessler, D. I., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31817f6d76 · Cited by 758
Metadata
- Authors
- Diringer, M. N.
- Venue
- Critical Care Medicine
- Published
- 2004-02
- Volume
- 32
- Issue
- 2
- Pages
- 559-564
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1998062141
- Cited by
- 236
- References
- 1
- FWCI
- 13.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Treatment of fever in the neurologic intensive care unit with a catheter-based heat exchange system. https://app.cochat.ai/papers/10.1097/01.ccm.0000108868.97433.3f
- The paper
- Diringer, M. N. (2004). Treatment of fever in the neurologic intensive care unit with a catheter-based heat exchange system. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000108868.97433.3f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.