Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Treatment of fever in the neurologic intensive care unit with a catheter-based heat exchange system

Diringer, Michael N.·2004·Critical Care Medicine

Abstract

CONTEXT: Elevated temperature worsens injury in experimental focal and global ischemia and brain trauma. Fever is common in patients with acute neurologic illness and independently predicts poor outcome. Conventional means of treating fever are not very effective in this population. OBJECTIVE: To study the effectiveness of a catheter-based heat exchange system in reducing elevated temperatures in critically ill neurologic and neurosurgical patients. DESIGN, INTERVENTION, SETTING, AND POPULATION: This was a prospective randomized, non-blinded trial that compared conventional treatment of fever (acetaminophen and cooling blankets) with conventional treatment plus an intravascular catheter-based heat exchange system (Alsius, Irvine, CA). Patients admitted to one of 13 neurologic intensive care units in academic medical centers were eligible if they a) suffered subarachnoid hemorrhage, intracerebral hemorrhage, ischemic infarction, or traumatic brain injury; b) had a temperature >38 degrees C on two occasions or for >4 continuous hrs; and c) required central venous access. MAIN OUTCOME MEASURE: The fever burden (area under the curve >38 degrees C) for 72 hrs was compared in an intention to treat analysis. Safety of the catheter system was monitored. RESULTS: A total of 296 patients were enrolled over 20 months. Forty-one percent had subarachnoid hemorrhage, 24% had traumatic brain injury, 23% had intracerebral hemorrhage, and 13% had ischemic stroke. The groups were matched in terms of age, body mass index, sex, and Glasgow Coma Scale score distribution. Fever burden was 7.92 vs. 2.87 degrees C-hrs in the conventional group and catheter groups, respectively (64% reduction, p <.01). There was no higher rate of infection or the use of sedatives, narcotics, or antibiotics in the catheter group. The catheter did not significantly increase risk to the patient beyond that of a central catheter. CONCLUSIONS: The addition of this catheter-based cooling system to conventional management significantly improves fever reduction in neurologic intensive care unit patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000108868.97433.3f

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 236

Metadata

Authors
Diringer, M. N.
Venue
Critical Care Medicine
Published
2004-02
Volume
32
Issue
2
Pages
559-564
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1998062141
Cited by
236
References
1
FWCI
13.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Treatment of fever in the neurologic intensive care unit with a catheter-based heat exchange system. https://app.cochat.ai/papers/10.1097/01.ccm.0000108868.97433.3f
The paper
Diringer, M. N. (2004). Treatment of fever in the neurologic intensive care unit with a catheter-based heat exchange system. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000108868.97433.3f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.