CoChat

Continuous positive airway pressure delivered with a “helmet”: Effects on carbon dioxide rebreathing*

Taccone, Paolo, Hess, Dean, Caironi, Pietro, Bigatello, Luca M. · 2004 · Critical Care Medicine
Cited by 181

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The "helmet" has been used as a novel interface to deliver noninvasive ventilation without applying direct pressure on the face. However, due to its large volume, the helmet may predispose to CO2 rebreathing. We hypothesized that breathing with the helmet is similar to breathing in a semiclosed environment, and therefore the PCO2 inside the helmet is primarily a function of the subject's CO2 production and the flow of fresh gas through the helmet. DESIGN: Human volunteer study. SETTING: Laboratory in a university teaching hospital. SUBJECTS: Eight healthy volunteers. INTERVENTIONS: We delivered continuous positive airway pressure (CPAP) with the helmet under a variety of ventilatory conditions in a lung model and in volunteers. MEASUREMENTS AND MAIN RESULTS: Gas flow and CO2 concentration at the airway were measured continuously. End-tidal PCO2, CO2 production, and ventilatory variables were subsequently computed. We found that a) when CPAP was delivered with a ventilator, the inspired CO2 of the volunteers was high (12.4 +/- 3.2 torr [1.7 +/- 0.4 kPa]); b) when CPAP was delivered with a continuous high flow system, inspired CO2 of the volunteers was low (2.5 +/- 1.2 torr [0.3 +/- 0.2 kPa]); and c) the inspired CO2 calculated mathematically for a semiclosed system model of CO2 rebreathing was highly correlated with the values measured in a lung model (r = .97, slope = 0.92, intercept = -1.17, p < .001) and in the volunteers (r = .94, slope = 0.96, intercept = 0.90, p < .001). CONCLUSIONS: a) The helmet predisposes to CO2 rebreathing and should not be used to deliver CPAP with a ventilator; b) continuous high flow minimizes CO2 rebreathing during CPAP with the helmet; and c) minute ventilation and Pco2 should be monitored during CPAP with the helmet.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000142577.63316.c0

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 181

Metadata

Authors
Taccone, P., Hess, D., Caironi, P., & Bigatello, L. M.
Venue
Critical Care Medicine
Published
2004-10
Volume
32
Issue
10
Pages
2090-2096
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2121215275
Cited by
181
References
10
FWCI
5.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.