The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Patient self-inflicted lung injury: implications for acute hypoxemic respiratory failure and ARDS patients on non-invasive support
Abstract
The role of spontaneous breathing among patients with acute hypoxemic respiratory failure and ARDS is debated: while avoidance of intubation with noninvasive ventilation (NIV) or high-flow nasal cannula improves clinical outcome, treatment failure worsens mortality. Recent data suggest patient self-inflicted lung injury (P-SILI) as a possible mechanism aggravating lung damage in these patients. P-SILI is generated by intense inspiratory effort yielding: (A) swings in transpulmonary pressure (i.e. lung stress) causing the inflation of big volumes in an aerated compartment markedly reduced by the disease-induced aeration loss; (B) abnormal increases in transvascular pressure, favouring negative-pressure pulmonary edema; (C) an intra-tidal shift of gas between different lung zones, generated by different transmission of muscular force (i.e. pendelluft); (D) diaphragm injury. Experimental data suggest that not all subjects are exposed to the development of P-SILI: patients with a PaO2/FiO2 ratio below 200 mmHg may represent the most at risk population. For them, current evidence indicates that high-flow nasal cannula alone may be superior to intermittent sessions of low-PEEP NIV delivered through face mask, while continuous high-PEEP helmet NIV likely promotes treatment success and may mitigate lung injury. The optimal initial noninvasive treatment of hypoxemic respiratory failure/ARDS remains however uncertain; high-flow nasal cannula and high-PEEP helmet NIV are promising tools to enhance success of the approach, but the best balance between these techniques has yet to be identified. During noninvasive support, careful clinical monitoring remains mandatory for prompt detection of treatment failure, in order not to delay intubation and protective ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-Flow Oxygen through Nasal Cannula in Acute Hypoxemic Respiratory Failure
Frat, J.-P., Thille, A. W., Mercat, A., Girault, C., Ragot, S., Perbet, S., Prat, G., Boulain, T., Morawiec, E., Cottereau, A., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1503326 · Cited by 2,342
Official ERS/ATS clinical practice guidelines: noninvasive ventilation for acute respiratory failure
Rochwerg, B., Brochard, L., Elliott, M. W., Hess, D., Hill, N. S., Nava, S., Navalesi, P., Antonelli, M., Brozek, J., Conti, G., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.02426-2016 · Cited by 1,668
Self-citationAntonelli, M., Conti, G., Rocco, M., Bufi, M., De Blasi, R. A., Vivino, G., Gasparetto, A., & Meduri, G. U. (1998) · New England Journal of Medicine · doi:10.1056/nejm199808133390703 · Cited by 1,014
Self-citationBellani, G., Laffey, J. G., Pham, T., Madotto, F., Fan, E., Brochard, L., Esteban, A., Gattinoni, L., Bumbasirevic, V., Piquilloud, L., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201606-1306oc · Cited by 667
Self-citationPhysiologic Effects of High-Flow Nasal Cannula in Acute Hypoxemic Respiratory Failure
Mauri, T., Turrini, C., Eronia, N., Grasselli, G., Volta, C. A., Bellani, G., & Pesenti, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201605-0916oc · Cited by 641
Respiratory mechanics during exercise in endurance‐trained men and women
Guenette, J. A., Witt, J. D., McKenzie, D. C., Road, J. D., & Sheel, A. W. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.126466 · Cited by 247
Demoule, A., Chevret, S., Carlucci, A., Kouatchet, A., Jaber, S., Meziani, F., Schmidt, M., Schnell, D., Clergue, C., Aboab, J., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4087-4 · Cited by 194
Cited by
Grieco, D. L., Menga, L. S., Cesarano, M., Rosà, T., Spadaro, S., Bitondo, M. M., Montomoli, J., Falò, G., Tonetti, T., Cutuli, S. L., et al. (2021) · JAMA · doi:10.1001/jama.2021.4682 · Cited by 473
Self-citationFerreyro, B. L., Angriman, F., Munshi, L., Del Sorbo, L., Ferguson, N. D., Rochwerg, B., Ryu, M. J., Saskin, R., Wunsch, H., da Costa, B. R., et al. (2020) · JAMA · doi:10.1001/jama.2020.9524 · Cited by 425
ERS clinical practice guidelines: high-flow nasal cannula in acute respiratory failure
Oczkowski, S., Ergan, B., Bos, L., Chatwin, M., Ferrer, M., Gregoretti, C., Heunks, L., Frat, J.-P., Longhini, F., Nava, S., et al. (2022) · European Respiratory Journal · doi:10.1183/13993003.01574-2021 · Cited by 388
Grieco, D. L., Maggiore, S. M., Roca, O., Spinelli, E., Patel, B. K., Thille, A. W., Barbas, C. S. V., de Acilu, M. G., Cutuli, S. L., Bongiovanni, F., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06459-2 · Cited by 286
Self-citation
Metadata
- Authors
- Grieco, D. L., Menga, L. S., Eleuteri, D., & Antonelli, M.
- Venue
- Minerva Anestesiologica
- Publisher
- Edizioni Minerva Medica
- Published
- 2019-09
- Volume
- 85
- Issue
- 9
- Pages
- 1014-1023
- ISSN
- 0375-9393 (ISSN-L)
- 1827-1596
- OpenAlex
- W2973055803
- Cited by
- 249
- References
- 7
- FWCI
- 23.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patient self-inflicted lung injury: implications for acute hypoxemic respiratory failure and ARDS patients on non-invasive support. https://app.cochat.ai/papers/10.23736/s0375-9393.19.13418-9
- The paper
- Grieco, D. L., Menga, L. S., Eleuteri, D., & Antonelli, M. (2019). Patient self-inflicted lung injury: implications for acute hypoxemic respiratory failure and ARDS patients on non-invasive support. Minerva Anestesiologica. https://doi.org/10.23736/s0375-9393.19.13418-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.