Effect of cerebral perfusion pressure augmentation on regional oxygenation and metabolism after head injury*
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: In this study we have used O positron emission tomography, brain tissue oxygen monitoring, and cerebral microdialysis to assess the effects of cerebral perfusion pressure augmentation on regional physiology and metabolism in the setting of traumatic brain injury. DESIGN: Prospective interventional study. SETTING: Neurosciences critical care unit of a university hospital. PATIENTS: Eleven acutely head-injured patients requiring norepinephrine to maintain cerebral perfusion pressure. INTERVENTIONS: Using positron emission tomography, we have quantified the response to an increase in cerebral perfusion pressure in a region of interest around a brain tissue oxygen sensor (Neurotrend) and microdialysis catheter. Oxygen extraction fraction and cerebral blood flow were measured with positron emission tomography at a cerebral perfusion pressure of approximately 70 mm Hg and approximately 90 mm Hg using norepinephrine to control cerebral perfusion pressure. All other aspects of physiology were kept stable. MEASUREMENTS AND MAIN RESULTS: Cerebral perfusion pressure augmentation resulted in a significant increase in brain tissue oxygen (17 +/- 8 vs. 22 +/- 8 mm Hg; 2.2 +/- 1.0 vs. 2.9 +/- 1.0 kPa, p < .001) and cerebral blood flow (27.5 +/- 5.1 vs. 29.7 +/- 6.0 mL/100 mL/min, p < .05) and a significant decrease in oxygen extraction fraction (33.4 +/- 5.9 vs. 30.3 +/- 4.6 %, p < .05). There were no significant changes in any of the microdialysis variables (glucose, lactate, pyruvate, lactate/pyruvate ratio, glycerol). There was a significant linear relationship between brain tissue oxygen and oxygen extraction fraction (r = .21, p < .05); the brain tissue oxygen value associated with an oxygen extraction fraction of 40% (the mean value for oxygen extraction fraction in normal controls) was 14 mm Hg (1.8 kPa). The cerebral perfusion pressure intervention resulted in a greater percentage increase in brain tissue oxygen than the percentage decrease in oxygen extraction fraction; this suggests that the oxygen gradients between the vascular and tissue compartments were reduced by the cerebral perfusion pressure intervention. CONCLUSIONS: Cerebral perfusion pressure augmentation significantly increased levels of brain tissue oxygen and significantly reduced regional oxygen extraction fraction. However, these changes did not translate into predictable changes in regional chemistry. Our results suggest that the ischemic level of brain tissue oxygen may lie at a level below 14 mm Hg (1.8 kPa); however, the data do not allow us to be more specific.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frackowiak, R. S. J., Lenzi, G.-L., Jones, T., & Heather, J. D. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198012000-00001 · Cited by 1,242 · cited 1×
“CBF, cerebral blood volume, oxygen extraction fraction (OEF), and cerebral metabolic rate of oxygen were calculated from radioactivity concentrations in tissue (PET) and arterial blood (discrete samples) using standard modeling techniques (19, 20) with a volume of distribution set to 0.”
MethodCEREBRAL BLOOD FLOW, BLOOD VOLUME AND OXYGEN UTILIZATION: NORMAL VALUES AND EFFECT OF AGE
LEENDERS, K. L., PERANI, D., LAMMERTSMA, A. A., HEATHER, J. D., BUCKINGHAM, P., JONES, T., HEALY, M. J. R., GIBBS, J. M., WISE, R. J. S., HATAZAWA, J., et al. (1990) · Brain · doi:10.1093/brain/113.1.27 · Cited by 1,093 · cited 3×
“05), and the PbO2 value associated with an OEF of 40% (the mean value for OEF in normal controls) (24) was 14 mm Hg (1.”
BackgroundMethodInfluentialCerebral perfusion pressure: management protocol and clinical results
Rosner, M. J., Rosner, S. D., & Johnson, A. H. (1995) · Journal of Neurosurgery · doi:10.3171/jns.1995.83.6.0949 · Cited by 963
Prevention of secondary ischemic insults after severe head injury
Robertson, C. S., Valadka, A. B., Hannay, H. J., Contant, C. F., Gopinath, S. P., Cormio, M., Uzura, M., & Grossman, R. G. (1999) · Critical Care Medicine · doi:10.1097/00003246-199910000-00002 · Cited by 748 · cited 2×
“Furthermore, CPP interventions may also result in cerebral (6) and systemic derangements (7).”
BackgroundStudholme, C., Hill, D. L. G., & Hawkes, D. J. (1997) · Medical Physics · doi:10.1118/1.598130 · Cited by 675 · cited 2×
“After reslicing CT images to 5 mm, PET and CT images were coregistered and analyzed using custom-designed automated software (PETAN) (21) incorporating elements of several different software packages, including Statistical Parametric Mapping (SPM99, Wellcome Department of Cognitive Neurology, London, UK), Matlab 5.2 (…”
BackgroundInfluentialRelationship of brain tissue PO2 to outcome after severe head injury
Valadka, A. B., Gopinath, S. P., Contant, C. F., Uzura, M., & ROBERTSON, C. S. (1998) · Critical Care Medicine · doi:10.1097/00003246-199809000-00029 · Cited by 456 · cited 1×
“Indeed, Paratrend sensors have been compared with Licox oxygen sensors and have been shown to be potentially inaccurate at low oxygen tensions (41).”
MethodBrain Oxygen Tension in Severe Head Injury
van den Brink, W. A., van Santbrink, H., Steyerberg, E. W., Avezaat, C. J. J., Suazo, J. A. C., Hogesteeger, C., Jansen, W. J., Kloos, L. M. H., Vermeulen, J., & Maas, A. I. R. (2000) · Neurosurgery · doi:10.1097/00006123-200004000-00018 · Cited by 438
Kiening, K. L., Unterberg, A. W., Bardt, T. F., Schneider, G.-H., & Lanksch, W. R. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.85.5.0751 · Cited by 408 · cited 1×
“Ischemic thresholds for PbO2 have been variably described using a number of different approaches such as outcome analysis after head injury (10, 39–41, 47– 50), relating PbO2 to recognized threshold limits for CBF (39, 48), relating PbO2 to jugular bulb oxygen saturation limits (51), assessing PbO2 in patients with a…”
BackgroundSpecialist neurocritical care and outcome from head injury
Patel, H. C., Menon, D. K., Tebbs, S., Hawker, R., Hutchinson, P. J., & Kirkpatrick, P. J. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1235-4 · Cited by 402 · cited 1×
“Patients were managed according to Addenbrooke’s Neurosciences Critical Care Unit protocols (16, 17), which include sedation with propofol and fentanyl, paralysis with atracurium, and support of CPP to 70 mm Hg.”
MethodSelf-citationChan, K.-H., Miller, J. D., Dearden, N. M., Andrews, P. J. D., & Midgley, S. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.77.1.0055 · Cited by 397
Cited by
Pathophysiology of traumatic brain injury
Werner, C., & Engelhard, K. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem131 · Cited by 1,712
Recent Advances in Pathophysiology of Traumatic Brain Injury
Kaur, P., & Sharma, S. (2018) · Current Neuropharmacology · doi:10.2174/1570159x15666170613083606 · Cited by 444
Consensus statement from the 2014 International Microdialysis Forum
Hutchinson, P. J., Jalloh, I., Helmy, A., Carpenter, K. L. H., Rostami, E., Bellander, B.-M., Boutelle, M. G., Chen, J. W., Claassen, J., Dahyot-Fizelier, C., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3930-y · Cited by 350
Self-citationNarotam, P. K., Morrison, J. F., & Nathoo, N. (2009) · Journal of Neurosurgery · doi:10.3171/2009.4.jns081150 · Cited by 279
Oddo, M., Levine, J. M., Mackenzie, L., Frangos, S., Feihl, F., Kasner, S. E., Katsnelson, M., Pukenas, B., Macmurtrie, E., Maloney-Wilensky, E., et al. (2011) · Neurosurgery · doi:10.1227/neu.0b013e3182287ca7 · Cited by 192
Cerebral microdialysis: research technique or clinical tool
Tisdall, M. M., & Smith, M. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael109 · Cited by 181
Physiologic and functional outcome correlates of brain tissue hypoxia in traumatic brain injury*
Chang, J. J. J., Youn, T. S., Benson, D., Mattick, H., Andrade, N., Harper, C. R., Moore, C. B., Madden, C. J., & Diaz-Arrastia, R. R. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e318192fbd7 · Cited by 177
“We anticipate that the FSE is best suited to measure subtle changes that are likely attributed to hypoxic secondary insults (17).”
BackgroundMethodSchmidt, J. M., Ko, S.-B., Helbok, R., Kurtz, P., Stuart, R. M., Presciutti, M., Fernandez, L., Lee, K., Badjatia, N., Connolly, E. S., et al. (2011) · Stroke · doi:10.1161/strokeaha.110.596874 · Cited by 158
Metadata
- Authors
- Johnston, A. J., Steiner, L. A., Coles, J. P., Chatfield, D. A., Fryer, T. D., Smielewski, P., Hutchinson, P. J., O’Connell, M. T., Al-Rawi, P. G., Aigbirihio, F. I., Clark, J. C., Pickard, J. D., Gupta, A. K., & Menon, D. K.
- Venue
- Critical Care Medicine
- Published
- 2005-01
- Volume
- 33
- Issue
- 1
- Pages
- 189-195
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2083554277
- Cited by
- 199
- References
- 42
- FWCI
- 11.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.