The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
A controlled trial of smart infusion pumps to improve medication safety in critically ill patients*
Abstract
OBJECTIVE: Intravenous medications are vital during inpatient management. Errors associated with the administration of medications through intravenous infusion pumps to critically ill patients can result in adverse drug events. We sought to assess the impact of smart pumps with integrated decision support software on the incidence and nature of medication errors and adverse drug events. DESIGN: We performed a prospective, randomized time-series trial and compared the serious medication error rate between intervention (decision support on) and control (decision support off) periods. Serious medication errors included both near-misses and preventable adverse drug events. Pump software produced log reports to help identify potential events. Events were presented to physicians for rating of event type, preventability, and severity. SETTING: Cardiac surgical intensive care and step-down units between February and December 2002. PATIENTS: Pump data were available for 744 cardiac surgery admissions. INTERVENTIONS: Decision support during medication administration provided feedback including alerts, reminders, and unit-specific drug rate limits. MEASUREMENTS AND MAIN RESULTS: We found a total of 180 serious medication errors, including 14 and 11 preventable adverse drug events and 73 and 82 nonintercepted potential adverse drug events in the control and intervention periods, respectively. The serious medication error rates in the control and intervention periods were 2.03 and 2.41 per 100 patient-pump-days, respectively (p = .124). We also found numerous opportunities for safety improvement. Violations of infusion practice during the intervention periods included 571 (25%) bypasses of the drug library. Medications were also frequently administered without documentation of physician orders in both periods (n = 823; 7.7%). CONCLUSION: Intravenous medication errors and adverse drug events were frequent and could be detected using smart pumps. We found no measurable impact on the serious medication error rate, likely in part due to poor compliance. Although smart pumps have great promise, technological and nursing behavioral factors must be addressed if these pumps are to achieve their potential for improving medication safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
To Err Is Human: Building a Safer Health System
(2000) · National Academies Press eBooks · doi:10.17226/9728 · Cited by 14,044
Hospital Nurse Staffing and Patient Mortality, Nurse Burnout, and Job Dissatisfaction
Aiken, L. H. (2002) · JAMA · doi:10.1001/jama.288.16.1987 · Cited by 5,226
Leape, L. L., Brennan, T. A., Laird, N., Lawthers, A. G., Localio, A. R., Barnes, B. A., Hebert, L., Newhouse, J. P., Weiler, P. C., & Hiatt, H. (1991) · New England Journal of Medicine · doi:10.1056/nejm199102073240605 · Cited by 3,711
Nurse-Staffing Levels and the Quality of Care in Hospitals
Needleman, J., Buerhaus, P., Mattke, S., Stewart, M., & Zelevinsky, K. (2002) · New England Journal of Medicine · doi:10.1056/nejmsa012247 · Cited by 2,241
Incidence of Adverse Drug Events and Potential Adverse Drug Events: Implications for Prevention
Bates, D. W. (1995) · JAMA · doi:10.1001/jama.1995.03530010043033 · Cited by 2,127
Self-citationBates, D. W. (1998) · JAMA · doi:10.1001/jama.280.15.1311 · Cited by 2,107
Self-citationAsh, J. S. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1471 · Cited by 1,789
Disrupted Routines: Team Learning and New Technology Implementation in Hospitals
Edmondson, A. C., Bohmer, R. M., & Pisano, G. P. (2001) · Administrative Science Quarterly · doi:10.2307/3094828 · Cited by 1,729
Systems Analysis of Adverse Drug Events
Leape, L. L. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530010049034 · Cited by 1,404
A Computer-Assisted Management Program for Antibiotics and Other Antiinfective Agents
Evans, R. S., Pestotnik, S. L., Classen, D. C., Clemmer, T. P., Weaver, L. K., Orme, J. F., Lloyd, J. F., & Burke, J. P. (1998) · New England Journal of Medicine · doi:10.1056/nejm199801223380406 · Cited by 1,061
Cited by
The Technology Acceptance Model: Its past and its future in health care
Holden, R. J., & Karsh, B.-T. (2010) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2009.07.002 · Cited by 2,669
Rothschild, J. M., Landrigan, C. P., Cronin, J. W., Kaushal, R., Lockley, S. W., Burdick, E., Stone, P. H., Lilly, C. M., Katz, J. T., Czeisler, C. A., et al. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000171609.91035.bd · Cited by 925
Self-citation(2007) · Endocrine Practice · doi:10.4158/ep.13.s1.1 · Cited by 699
The impact of health information technology on patient safety
Alotaibi, Y. K., & Federico, F. (2017) · Saudi Medical Journal · doi:10.15537/smj.2017.12.20631 · Cited by 467
Poon, E. G., Cina, J. L., Churchill, W., Patel, N., Featherstone, E., Rothschild, J. M., Keohane, C. A., Whittemore, A. D., Bates, D. W., & Gandhi, T. K. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-145-6-200609190-00006 · Cited by 294
Self-citation
Metadata
- Authors
- Rothschild, J. M., Keohane, C. A., Cook, E. F., Orav, E. J., Burdick, E., Thompson, S., Hayes, J., & Bates, D. W.
- Venue
- Critical Care Medicine
- Published
- 2005-03
- Volume
- 33
- Issue
- 3
- Pages
- 533-540
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2132693231
- Cited by
- 301
- References
- 33
- FWCI
- 31.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A controlled trial of smart infusion pumps to improve medication safety in critically ill patients*. https://app.cochat.ai/papers/10.1097/01.ccm.0000155912.73313.cd
- The paper
- Rothschild, J. M., Keohane, C. A., Cook, E. F., Orav, E. J., Burdick, E., Thompson, S., Hayes, J., & Bates, D. W. (2005). A controlled trial of smart infusion pumps to improve medication safety in critically ill patients*. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000155912.73313.cd
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.