Medication Dispensing Errors and Potential Adverse Drug Events before and after Implementing Bar Code Technology in the Pharmacy
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Many dispensing errors made in hospital pharmacies can harm patients. Some hospitals are investing in bar code technology to reduce these errors, but data about its efficacy are limited. OBJECTIVE: To evaluate whether implementation of bar code technology reduced dispensing errors and potential adverse drug events (ADEs). DESIGN: Before-and-after study using direct observations. SETTING: Hospital pharmacy at a 735-bed tertiary care academic medical center. INTERVENTION: A bar code-assisted dispensing system was implemented in 3 configurations. In 2 configurations, all doses were scanned once during the dispensing process. In the third configuration, only 1 dose was scanned if several doses of the same medication were being dispensed. MEASUREMENTS: Target dispensing errors, defined as dispensing errors that bar code technology was designed to address, and target potential ADEs, defined as target dispensing errors that can harm patients. RESULTS: In the pre- and post-bar code implementation periods, the authors observed 115,164 and 253,984 dispensed medication doses, respectively. Overall, the rates of target potential ADEs and all potential ADEs decreased by 74% and 63%, respectively. Of the 3 configurations of bar code technology studied, the 2 configurations that required staff to scan all doses had a 93% to 96% relative reduction in the incidence of target dispensing errors (P < 0.001) and 86% to 97% relative reduction in the incidence of potential ADEs (P < 0.001). However, the configuration that did not require scanning of every dose had only a 60% relative reduction in the incidence of target dispensing errors (P < 0.001) and an increased (by 2.4-fold) incidence of target potential ADEs (P = 0.014). There were several potentially life-threatening ADEs involving intravenous dopamine and intravenous heparin in that configuration. LIMITATIONS: The authors used surrogate outcomes; did not mask assessors to the purpose of study; and excluded the controlled substance fill process (a process with low error rates at baseline) from the study, which may bias the combined decrease in error rates toward a larger magnitude. CONCLUSIONS: The overall rates of dispensing errors and potential ADEs substantially decreased after implementing bar code technology. However, the technology should be configured to scan every dose during the dispensing process.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Brennan, T. A., Leape, L. L., Laird, N. M., Hebert, L., Localio, A. R., Lawthers, A. G., Newhouse, J. P., Weiler, P. C., & Hiatt, H. H. (1991) · New England Journal of Medicine · doi:10.1056/nejm199102073240604 · Cited by 4,627
Incidence of Adverse Drug Events and Potential Adverse Drug Events: Implications for Prevention
Bates, D. W. (1995) · JAMA · doi:10.1001/jama.1995.03530010043033 · Cited by 2,127 · cited 1×
“edication errors in hospitals are common (1, 2 ), and dispensing errors made in the pharmacy contribute considerably to these errors (3).”
BackgroundSelf-citationRole of Computerized Physician Order Entry Systems in Facilitating Medication Errors
Koppel, R. (2005) · JAMA · doi:10.1001/jama.293.10.1197 · Cited by 2,126
Bates, D. W. (1998) · JAMA · doi:10.1001/jama.280.15.1311 · Cited by 2,107
Self-citationMaking health care safer: a critical analysis of patient safety practices.
Shojania, K. G., Duncan, B. W., McDonald, K. M., Wachter, R. M., & Markowitz, A. J. (2001) · PubMed Central · Cited by 1,612
Pharmacist Participation on Physician Rounds and Adverse Drug Events in the Intensive Care Unit
Leape, L. L. (1999) · JAMA · doi:10.1001/jama.282.3.267 · Cited by 1,599 · cited 1×
“Given these magnitudes in error reduction, bar code technology in the pharmacy compares favorably with other patient safety interventions, such as computerized physician order entry (17, 18) and pharmacist participation in intensive care unit rounds ( 19 , 20).”
Self-citationSystems Analysis of Adverse Drug Events
Leape, L. L. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530010049034 · Cited by 1,404 · cited 2×
“edication errors in hospitals are common (1, 2), and dispensing errors made in the pharmacy contribute considerably to these errors ( 3 ).”
BackgroundAdverse Drug Events in Ambulatory Care
Gandhi, T. K., Weingart, S. N., Borus, J., Seger, A. C., Peterson, J., Burdick, E., Seger, D. L., Shu, K., Federico, F., Leape, L. L., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmsa020703 · Cited by 1,345 · cited 1×
“The level of potential harm was further classified as significant, serious, or life-threatening ( 15 , 16).”
BackgroundSelf-citationBush, G. W. (2006) · Cited by 756
Kucukarslan, S. N., Peters, M., Mlynarek, M., & Nafziger, D. A. (2003) · Archives of Internal Medicine · doi:10.1001/archinte.163.17.2014 · Cited by 514 · cited 1×
“Given these magnitudes in error reduction, bar code technology in the pharmacy compares favorably with other patient safety interventions, such as computerized physician order entry (17, 18) and pharmacist participation in intensive care unit rounds (19, 20 ).”
Research works printed but not linked: 2
- Cina JL, 2006, Jt Comm J Qual Patient Saf, 32, 73
- 2004, Fed Regist, 69, 9119
Cited by
The incidence and nature of in-hospital adverse events: a systematic review
de Vries, E. N., Ramrattan, M. A., Smorenburg, S. M., Gouma, D. J., & Boermeester, M. A. (2008) · Quality and Safety in Health Care · doi:10.1136/qshc.2007.023622 · Cited by 1,784
Harrison, M. I., Koppel, R., & Bar-Lev, S. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2384 · Cited by 691
Koppel, R., Wetterneck, T., Telles, J. L., & Karsh, B.-T. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2616 · Cited by 685
“There is evidence that BCMA systems can reduce pharmacy dispensing errors,”
BackgroundEffect of Bar-Code Technology on the Safety of Medication Administration
Poon, E. G., Keohane, C. A., Yoon, C. S., Ditmore, M., Bane, A., Levtzion-Korach, O., Moniz, T., Rothschild, J. M., Kachalia, A. B., Hayes, J., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmsa0907115 · Cited by 588
Self-citationHealth IT and Patient Safety: Building Safer Systems for Better Care
Chou, D. (2012) · JAMA · doi:10.1001/jama.308.21.2282-a · Cited by 503
Metadata
- Authors
- Poon, E. G., Cina, J. L., Churchill, W., Patel, N., Featherstone, E., Rothschild, J. M., Keohane, C. A., Whittemore, A. D., Bates, D. W., & Gandhi, T. K.
- Affiliations
- Brigham and Women's Hospital (US)
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2006-09-19
- Volume
- 145
- Issue
- 6
- Pages
- 426-434
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1979757243
- Cited by
- 294
- References
- 24
- Citations by year
- 2026: 6 · 2025: 2 · 2024: 9 · 2023: 6 · 2022: 7 · 2021: 10 · 2020: 10 · 2019: 9 · 2018: 11 · 2017: 9 · 2016: 10 · 2015: 19 · 2014: 22 · 2013: 16 · 2012: 21
- FWCI
- 34.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- UCLA - Biblioteca de Ciencias de la Salud (submittedVersion)
- Annals of Internal Medicine
- Funders
- Agency for Healthcare Research and Quality (HS14053-02)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Health Sciences › Medicine › Geriatrics and Gerontology › Pharmaceutical Practices and Patient Outcomes
- Health Sciences › Health Professions › Pharmacy › Pharmacy and Medical Practices
- Keywords
- medication dispensing errors, barcode technology, adverse drug reactions, hospital pharmacy, drug safety, error reduction, intravenous heparin, technology configuration, patient harm prevention, medication errors
- MeSH terms
- Electronic Data Processing, Drug Labeling, Humans, Medication Errors, Pharmacy Service, Hospital, United States, Safety Management, Drug-Related Side Effects and Adverse Reactions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Medication Dispensing Errors and Potential Adverse Drug Events before and after Implementing Bar Code Technology in the Pharmacy. https://app.cochat.ai/papers/10.7326/0003-4819-145-6-200609190-00006
- The paper
- Poon, E. G., Cina, J. L., Churchill, W., Patel, N., Featherstone, E., Rothschild, J. M., Keohane, C. A., Whittemore, A. D., Bates, D. W., & Gandhi, T. K. (2006). Medication Dispensing Errors and Potential Adverse Drug Events before and after Implementing Bar Code Technology in the Pharmacy. Annals of Internal Medicine. https://doi.org/10.7326/0003-4819-145-6-200609190-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.