Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 307

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Impact of tracheotomy on sedative administration, sedation level, and comfort of mechanically ventilated intensive care unit patients*

Nieszkowska, Ania, Combes, Alain, Luyt, Charles-Edouard, Ksibi, Hichem, Trouillet, Jean-Louis, Gibert, Claude, Chastre, Jean·2005·Critical Care Medicine

Abstract

OBJECTIVE: To assess the impact of tracheotomy on sedative administration, sedation level, and autonomy of mechanically-ventilated intensive care unit (ICU) patients. DESIGN, SETTING, AND PATIENTS: In this observational study, the charts of all consecutive patients undergoing mechanical ventilation requiring tracheotomy over a 14-month period in our 18-bed tertiary care ICU were reviewed retrospectively. Patients' sedation levels (according to the Riker's 7-level sedation-agitation score) and intravenous (fentanyl and midazolam) and oral (clorazepate and haloperidol) sedative administration were measured daily during the 7 days before and after tracheotomy. We also recorded patients for whom chair positioning and oral alimentation became possible in the days following tracheotomy. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Tracheotomy was performed on 72 (23.1%) of the 312 patients undergoing mechanical ventilation for > or = 48 hrs. After tracheotomy, median (25th, 75th percentiles) fentanyl and midazolam administration decreased from 866 (191, 1672) to 71 (3, 426) microg/(patient.day) and from 44 (16, 128) to 7 (1, 42) mg/(patient.day) (p < .001), respectively. Concomitant median time spent heavily sedated decreased from 7 (3, 17) to 1 (0, 6) hrs/day (p < .001), with no increase in agitation time. During the 7 days following tracheotomy, partial oral alimentation became possible for 35 patients (48.6%) and out-of-bed positioning became possible for 16 patients (22.2%). CONCLUSION: On the basis of these observations, we conclude that tracheotomized mechanically ventilated ICU patients required less intravenous sedative administration, spent less time heavily sedated, and achieved more autonomy earlier.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000186898.58709.aa

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 307

Metadata

Authors
Nieszkowska, A., Combes, A., Luyt, C.-E., Ksibi, H., Trouillet, J.-L., Gibert, C., & Chastre, J.
Venue
Critical Care Medicine
Published
2005-11
Volume
33
Issue
11
Pages
2527-2533
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2089278169
Cited by
307
References
25
FWCI
8.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of tracheotomy on sedative administration, sedation level, and comfort of mechanically ventilated intensive care unit patients*. https://app.cochat.ai/papers/10.1097/01.ccm.0000186898.58709.aa
The paper
Nieszkowska, A., Combes, A., Luyt, C.-E., Ksibi, H., Trouillet, J.-L., Gibert, C., & Chastre, J. (2005). Impact of tracheotomy on sedative administration, sedation level, and comfort of mechanically ventilated intensive care unit patients*. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000186898.58709.aa

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.