Central venous pressure: A useful but not so simple measurement
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To review the clinical use of central venous pressure measurements. DATA SOURCES: The Medline database, biographies of selected articles, and the author's personal database. DATA SYNTHESIS: Four basic principles must be considered. Pressure measurements with fluid-filled systems are made relative to an arbitrary reference point. The pressure that is important for preload of the heart is the transmural pressure, whereas the pressure relative to atmosphere still affects other vascular beds outside the thorax. The central venous pressure is dependent upon the interaction of cardiac function and return function. There is a plateau to the cardiac function curve, and once it is reached, further volume loading will not increase cardiac output. CONCLUSIONS: If careful attention is paid to proper measurement techniques, central venous pressure can be very useful clinically. However, the physiologic or pathophysiological significance of the central venous pressure should be considered only with a corresponding measurement of cardiac output or at least a surrogate measure of cardiac output.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Boldt, J., Lenz, M., Kumle, B., et al. (1998) · Intensive Care Medicine · doi:10.1007/s001340050536 · Cited by 148
RetractedPredicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367 · cited 1×
“A difficult problem for managing the care of patients is that the central venous pressure at which cardiac filling is limited is highly variable (3, 15, 16).”
BackgroundBate's guide to physical examination and history taking
Bickley, L. S., & Szilagyi, P. G. (1995) · Cited by 1,000
Kumar, A., Anel, R., Bunnell, E., Habet, K., Zanotti, S., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000114996.68110.c9 · Cited by 800
Boulain, T., Achard, J.-M., Teboul, J.-L., Richard, C., Perrotin, D., & Ginies, G. (2002) · Chest · doi:10.1378/chest.121.4.1245 · Cited by 351 · cited 1×
“An interesting approach to a volume challenge that can avoid extrinsic volume infusion is to elevate the patient’s leg to provide an autotransfusion and observe the cardiac response (18).”
BackgroundReliability of clinical monitoring to assess blood volume in critically ill patients
SHIPPY, C. R., APPEL, P. L., & SHOEMAKER, W. C. (1984) · Critical Care Medicine · doi:10.1097/00003246-198402000-00005 · Cited by 342
Respiratory variations in right atrial pressure predict the response to fluid challenge
Magder, S. A., Georgiadis, G., & Cheong, T. H. (1992) · Journal of Critical Care · doi:10.1016/0883-9441(92)90032-3 · Cited by 188 · cited 2×
“A difficult problem for managing the care of patients is that the central venous pressure at which cardiac filling is limited is highly variable (3, 15, 16).”
BackgroundSelf-citationAdaptations of the Peripheral Circulation to PEEP
Nanas, S., & Magder, S. A. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/146.3.688 · Cited by 125 · cited 1×
“For example, the normal gradient for venous return is in the range of 4 mm Hg to 6 mm Hg (8), and the normal cardiac function curve starts at 0 and plateaus in most people by 10 mm Hg.”
BackgroundSelf-citationHow to use central venous pressure measurements
Magder, S. A. (2005) · Current Opinion in Critical Care · doi:10.1097/01.ccx.0000163197.70010.33 · Cited by 111 · cited 1×
“I argue that the reason for the lack of appreciation of the usefulness of the central venous pressure is the failure to consider the physiologic determinants of the central venous pressure and potential errors in measurement (6, 7).”
BackgroundSelf-citationMagder, S. A., & Lagonidis, D. (1999) · Journal of Critical Care · doi:10.1016/s0883-9441(99)90030-8 · Cited by 72 · cited 1×
“A difficult problem for managing the care of patients is that the central venous pressure at which cardiac filling is limited is highly variable (3, 15, 16).”
BackgroundSelf-citationRespiratory-Circulatory Interactions in Health and Disease
Scharf, S., Pinsky, M. R., & Magder, S. (2001) · CRC Press eBooks · doi:10.1201/b14017 · Cited by 69
Self-citationCardiac versus noncardiac limits to exercise after heart transplantation
Notarius, C. F., Levy, R. D., Tully, A., FITCHETT, D. H., & Magder, S. A. (1998) · American Heart Journal · doi:10.1016/s0002-8703(98)70103-6 · Cited by 56
Self-citation
Cited by
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Dellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-007-0934-2 · Cited by 6,772
Severe Sepsis and Septic Shock
Angus, D. C., & van der Poll, T. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208623 · Cited by 3,961
Bioadhesive ultrasound for long-term continuous imaging of diverse organs
Wang, C., Chen, X., Wang, L., Makihata, M., Liu, H.-C., Zhou, T., & Zhao, X. (2022) · Science · doi:10.1126/science.abo2542 · Cited by 599
Metadata
- Authors
- Magder, S.
- Venue
- Critical Care Medicine
- Published
- 2006-08
- Volume
- 34
- Issue
- 8
- Pages
- 2224-2227
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1965123693
- Cited by
- 174
- References
- 12
- FWCI
- 7.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.