Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 179

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period*

Hamzaoui, Olfa, Monnet, Xavier, Richard, Christian, Osman, David, Chemla, Denis, Teboul, Jean-Louis·2008·Critical Care Medicine

Abstract

OBJECTIVES: To examine whether the agreement between pulse contour and transpulmonary thermodilution cardiac index (CI) measurements is altered by changes in vascular tone within an up to 6-hr calibration-free period. DESIGN: Observational study. SETTING: Medical intensive care unit of a university hospital. PATIENTS: Fifty-nine critically ill patients. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Data from 59 critically ill patients equipped with a PiCCO device were retrospectively analyzed. The database contained the transpulmonary thermodilution CI (CI(T)) value obtained at each time point the device was calibrated and the pulse contour CI (CI(PC)) value recorded immediately before this time point. Seven subsets of CI pairs were defined according to intervals of time elapsed from the previous calibration (within the first 30 mins, between 30 mins and 1 hr, and every hour up to 6 hrs). In the whole set of 400 CI pairs, CI(PC) correlated with CI(T) (r2 = .68, p < .001). The bias +/- SD was 0.12 +/- 0.61 L/min/m2, and the percentage error was 35%. Among the seven time-interval subsets, the percentage error was <30% only in the two first ones (27% and 26%, respectively). When changes in systemic vascular resistance by >15% occurred (129 times), CI(PC) correlated with CI(T) (r2 = .64), the bias +/- SD was 0.12 +/- 0.62 L/min/m2, and the percentage error was 36%. In the subset of CI pairs recorded within the 1-hr calibration-free period while vascular resistance changed by >15% (n = 32), the bias +/- SD was 0.04 +/- 0.47 L/min/m and the percentage error was 29%. CONCLUSIONS: Our study in critically ill patients suggests that the agreement between pulse contour cardiac output and transpulmonary thermodilution cardiac output was not significantly influenced by changes in vascular tone. However, after a 1-hr calibration-free period, recalibration may be encouraged. Such a procedure provides helpful information drawn from other thermodilution-derived variables.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.ob013e318161fec4

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 179

Metadata

Authors
Hamzaoui, O., Monnet, X., Richard, C., Osman, D., Chemla, D., & Teboul, J.-L.
Venue
Critical Care Medicine
Published
2008-02
Volume
36
Issue
2
Pages
434-440
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1967147672
Cited by
179
References
2
FWCI
16.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period*. https://app.cochat.ai/papers/10.1097/01.ccm.ob013e318161fec4
The paper
Hamzaoui, O., Monnet, X., Richard, C., Osman, D., Chemla, D., & Teboul, J.-L. (2008). Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period*. Critical Care Medicine. https://doi.org/10.1097/01.ccm.ob013e318161fec4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.