ReGel® Polymer-based Delivery of Interleukin-2 as a Cancer Treatment
The DOI matches its Crossref record.
Abstract
ReGel is an aqueous, filter sterilizable ABA tri-block polymer consisting of poly-(lactide-co-glycolide) and polyethylene glycol. We tested the suitability of this polymer to provide sustained interleukin-2 (IL-2) delivery for cancer immunotherapy. ReGel/IL-2 is liquid at or below room temperature, and is easily injectable through narrow gauge needles, but undergoes a reversible thermal transition into a bioerodible depot at body temperature. We demonstrated that ReGel/IL-2 releases IL-2 over 72 to 96 hours in vitro, without loss of bioactivity. Pharmacokinetic studies after peritumoral injection of 0.1 mL ReGel/IL-2 in mice demonstrated an early burst of IL-2 release, followed by more sustained release kinetics over 96 hours (T(1/2)beta 48 h). Less than 1.5% of the injected dose was detectable in blood or kidneys during the first 48 hours. A single peritumoral dose of ReGel/IL-2 [1 to 4 million international units (MIU) ReGel/IL-2, split into 4 quadrant injections] was administered to mice bearing subcutaneous RD-995 spindle cell carcinoma. Only the highest dose of ReGel/IL-2 tested (4.0 MIU) resulted in significant hypotension on day 3 after injection. Weekly treatment of Meth A fibrosarcoma and RENCA renal carcinoma with ReGel/IL-2 (2 MIU/dose) induced a significant reduction in tumor growth and improved survival. Reduction in tumor growth at implants remote from treated lesions was also observed, suggesting systemic activation of antitumor immunity. These findings establish that peritumoral injection of ReGel/IL-2 is an effective delivery system for cancer immunotherapy, while decreasing IL-2 toxicity. This polymer delivery system is likely to be broadly applicable for sustained delivery of other cytokines and peptides.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrogels in a historical perspective: From simple networks to smart materials
Buwalda, S. J., Boere, K. W. M., Dijkstra, P. J., Feijen, J., Vermonden, T., & Hennink, W. E. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.03.052 · Cited by 994
In situ gelling stimuli-sensitive block copolymer hydrogels for drug delivery
He, C., Kim, S. W., & Lee, D. S. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.01.005 · Cited by 867
Injectable Biodegradable Hydrogels
Nguyen, M. K., & Lee, D. S. (2010) · Macromolecular Bioscience · doi:10.1002/mabi.200900402 · Cited by 481
Controlled drug delivery in tissue engineering
Biondi, M., Ungaro, F., Quaglia, F., & Netti, P. A. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.038 · Cited by 412
OncoGel (ReGel/paclitaxel) — Clinical applications for a novel paclitaxel delivery system
Elstad, N. L., & Fowers, K. D. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.04.010 · Cited by 286
Self-citation
Metadata
- Authors
- Samlowski, W. E., McGregor, J. R., Jurek, M., Baudys, M., Zentner, G. M., & Fowers, K. D.
- Venue
- Journal of Immunotherapy
- Published
- 2006-09
- Volume
- 29
- Issue
- 5
- Pages
- 524-535
- ISSN
- 1524-9557 (ISSN-L)
- OpenAlex
- W1985684473
- Cited by
- 49
- References
- 0
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ReGel® Polymer-based Delivery of Interleukin-2 as a Cancer Treatment. https://app.cochat.ai/papers/10.1097/01.cji.0000211306.05869.25
- The paper
- Samlowski, W. E., McGregor, J. R., Jurek, M., Baudys, M., Zentner, G. M., & Fowers, K. D. (2006). ReGel® Polymer-based Delivery of Interleukin-2 as a Cancer Treatment. Journal of Immunotherapy. https://doi.org/10.1097/01.cji.0000211306.05869.25
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.