CoChat

Comparison of agreement between clinic and home-measured blood pressure in the Finnish population: the Finn-HOME Study

Niiranen, Teemu J, Jula, Antti M, Kantola, Ilkka M, Reunanen, Antti · 2006 · Journal of Hypertension
Cited by 49

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The purpose of this study was to assess the agreement, mean difference, and the detection and control rates of hypertension, between home and clinic blood pressure (BP) measurement in the Finnish population. Variation in home BP during the measurements was also examined. METHODS: We studied a representative sample of the adult population (2051 45-74-year-old individuals) in Finland. Subjects included in the study underwent a clinical interview and measurement of clinic and home BP. Thresholds for elevated clinic and home BP were 140/90 and 135/85 mmHg. RESULTS: The mean difference between home and clinic BP, which increased with BP, was 7.7/3.4 mmHg. Overall agreement in diagnosis was only 75.2% (kappa coefficient 0.50). As compared with home BP, clinic BP overestimated the prevalence of hypertension (48.8 versus 42.5%, P < 0.001) and non-significantly underestimated the control of hypertension (28.7 versus 32.8%, P = 0.11). Evening home BP was 4.1/0.4 mmHg higher than morning BP among untreated subjects, but this difference was non-existent or reversed (0.5/-1.4 mmHg) among treated hypertensive individuals. Home BP decreased with an increasing number of measurements. CONCLUSIONS: The agreement between home and clinic BP in diagnosing hypertension according to the current guidelines is moderate at best, and the difference between home and clinic BP becomes larger at higher levels of BP. Because of the noticeable differences between these two methods, and the better prognostic accuracy of home BP, we endorse the use of home measurements in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.hjh.0000239290.94764.81

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 49

Metadata

Authors
Niiranen, T. J., Jula, A. M., Kantola, I. M., & Reunanen, A.
Venue
Journal of Hypertension
Published
2006-08
Volume
24
Issue
8
Pages
1549-1555
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2008660095
Cited by
49
References
8
FWCI
0.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of agreement between clinic and home-measured blood pressure in the Finnish population: the Finn-HOME Study. https://app.cochat.ai/papers/10.1097/01.hjh.0000239290.94764.81
The paper
Niiranen, T. J., Jula, A. M., Kantola, I. M., & Reunanen, A. (2006). Comparison of agreement between clinic and home-measured blood pressure in the Finnish population: the Finn-HOME Study. Journal of Hypertension. https://doi.org/10.1097/01.hjh.0000239290.94764.81

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.