OCCUPATIONAL RADIATION DOSES TO OPERATORS PERFORMING CARDIAC CATHETERIZATION PROCEDURES
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Cardiac catheterization procedures using fluoroscopy reduce patient morbidity and mortality compared to operative procedures. These diagnostic and therapeutic procedures require radiation exposure to patients and physicians. The objectives of the present investigation were to provide a systematic comprehensive summary of the reported radiation doses received by operators due to diagnostic or interventional fluoroscopically-guided procedures, to identify the primary factors influencing operator radiation dose, and to evaluate whether there have been temporal changes in the radiation doses received by operators performing these procedures. Using PubMed, we identified all English-language journal articles and other published data reporting radiation exposures to operators from diagnostic or interventional fluoroscopically-guided cardiovascular procedures from the early 1970's through the present. We abstracted the reported radiation doses, dose measurement methods, fluoroscopy system used, operational features, radiation protection features, and other relevant data. We calculated effective doses to operators in each study to facilitate comparisons. The effective doses ranged from 0.02-38.0 microSv for DC (diagnostic catheterizations), 0.17-31.2 microSv for PCI (percutaneous coronary interventions), 0.24-9.6 microSv for ablations, and 0.29-17.4 microSv for pacemaker or intracardiac defibrillator implantations. The ratios of doses between various anatomic sites and the thyroid, measured over protective shields, were 0.9 +/- 1.0 for the eye, 1.0 +/- 1.5 for the trunk, and 1.3 +/- 2.0 for the hand. Generally, radiation dose is higher on the left side of an operator's body, because the operator's left side is closer to the primary beam when standing at the patient's right side. Modest operator dose reductions over time were observed for DC and ablation, primarily due to reduction in patient doses due to decreased fluoroscopy/cineradiography time and dose rate by technology improvement. Doses were not reduced over time for PCI. The increased complexity of medical procedures appears to have offset dose reductions due to improvements in technology. The large variation in operator doses observed for the same type of procedure suggests that optimizing procedure protocols and implementing general use of the most effective types of protective devices and shields may reduce occupational radiation doses to operators. We had considerable difficulty in comparing reported dosimetry results because of significant differences in dosimetric methods used in each study and multiple factors influencing the actual doses received. Better standardization of dosimetric methods will facilitate future analyses aimed at determining how well medical radiation workers are being protected.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Classical and Modern Regression With Applications.
Steinhorst, R. K., & Myers, R. H. (1988) · Journal of the American Statistical Association · doi:10.2307/2288958 · Cited by 3,690
Writing Group Members, Thom, T., Haase, N., Rosamond, W., Howard, V. J., Rumsfeld, J., Manolio, T., Zheng, Z.-J., Flegal, K., O’Donnell, C., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.171600 · Cited by 3,451
Rosamond, W., Flegal, K., Friday, G., Furie, K., Go, A., Greenlund, K., Haase, N., Ho, M., Howard, V., Kissela, B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.179918 · Cited by 3,277 · cited 1×
“Stents have been increasingly used since the mid-1990s, with a 147% increase in the rate of coronary stent insertion between 1996 and 2000 (Rosamond et al. 2007).”
MethodClassical and Modern Regression with Applications
Ziegel, E. R., & Myers, R. (1991) · Technometrics · doi:10.2307/1269070 · Cited by 2,328
WRITING COMMITTEE MEMBERS, Hirshfeld, J. W., Balter, S., Brinker, J. A., Kern, M. J., Klein, L. W., Lindsay, B. D., Tommaso, C. L., Tracy, C. M., Wagner, L. K., et al. (2005) · Circulation · doi:10.1161/01.cir.0000157946.29224.5d · Cited by 440
Self-citationFluoroscopy: Patient Radiation Exposure Issues
Mahesh, M. (2001) · RadioGraphics · doi:10.1148/radiographics.21.4.g01jl271033 · Cited by 410
Calkins, H., Niklason, L., Sousa, J., el-Atassi, R., Langberg, J., & Morady, F. (1991) · Circulation · doi:10.1161/01.cir.84.6.2376 · Cited by 238
NASPE Survey on Catheter Ablation
SCHEINMAN, M. M. (1995) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1995.tb06733.x · Cited by 176
Lindsay, B. D., Eichung, J. O., Ambos, H. D., & CAIN, M. E. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)91278-c · Cited by 149
X-ray dose and associated risks from radiofrequency catheter ablation procedures
McFadden, S. L., Mooney, R. B., & Shepherd, P. (2002) · British Journal of Radiology · doi:10.1259/bjr.75.891.750253 · Cited by 123
Percutaneous coronary interventions in Europe 1992?2001
Togni, M., Balmer, F., Pfiffner, D., Maier, W., Am, Z., & Meier, B. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.04.024 · Cited by 114
Radiation Exposure During Radiofrequency Catheter Ablation for Atrial Fibrillation
Macle, L., Weerasooriya, R., Jaı̈s, P., Scavée, C., Raybaud, F., Choi, K., Hocini, M., Clémenty, J., & Haı̈ssaguerre, M. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.00034.x · Cited by 86
EFSTATHOPOULOS, E. P., Katritsis, D. G., Kottou, S., Kalivas, N., Tzanalaridou, E., Giazitzoglou, E., Korovesis, S., & Faulkner, K. (2006) · EP Europace · doi:10.1093/europace/eul041 · Cited by 76
Reduction of Radiation Exposure in the Cardiac Electrophysiology Laboratory
Wittkampf, F. H. M., WEVER, E. F. D., VOS, K., Geleijns, J., Schalij, M. J., TOL, J. V. D., & de Medina, E. O. R. (2000) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2000.01638.x · Cited by 55
Chida, K., Fuda, K., Saito, H., et al. (2006) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20961 · Cited by 46
Turf Battles in Coronary Revascularization
Huckman, R. S., & Pisano, G. P. (2005) · New England Journal of Medicine · doi:10.1056/nejmp048242 · Cited by 23
Kovoor, P., Uther, J. B., Ricciardello, M., Ross, D. L., & Collins, L. (1995) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.1995.tb01493.x · Cited by 13
Malsky, S. J., Haft, J., Hayt, D. B., Gould, L., Blatt, C. M., Simon, D. F., & Roswit, B. (1972) · PubMed · Cited by 7
Cited by
Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., MacVittie, T. J., Aleman, B. M., Edgar, A. B., Mabuchi, K., Muirhead, C. R., et al. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.02.001 · Cited by 1,604
ICRP Publication 120: Radiological Protection in Cardiology
Cousins, C., Miller, D. L., Bernardi, G., Rehani, M. M., Schofield, P., Vañó, E., Einstein, A. J., Geiger, B., Heintz, P., Padovani, R., et al. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.09.001 · Cited by 428
Self-citationRadiation Cataract Risk in Interventional Cardiology Personnel
Vano, E., Kleiman, N. J., Duran, A., Rehani, M. M., Echeverri, D., & Cabrera, M. (2010) · Radiation Research · doi:10.1667/rr2207.1 · Cited by 360
Linet, M. S., Kim, K. P., & Rajaraman, P. (2009) · Pediatric Radiology · doi:10.1007/s00247-008-1026-3 · Cited by 305
Self-citationRadiation safety program for the cardiac catheterization laboratory
E. Chambers, C., A. Fetterly, K., Holzer, R., Paul Lin, P., C. Blankenship, J., Balter, S., & K. Laskey, W. (2011) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22867 · Cited by 301
Self-citation
Metadata
- Authors
- Kim, K. P., Miller, D. L., Balter, S., Kleinerman, R. A., Linet, M. S., Kwon, D., & Simon, S. L.
- Venue
- Health Physics
- Published
- 2008-03
- Volume
- 94
- Issue
- 3
- Pages
- 211-227
- ISSN
- 0017-9078 (ISSN-L)
- OpenAlex
- W2079219543
- Cited by
- 285
- References
- 18
- FWCI
- 13.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.