CoChat

Conservation of Residual Acoustic Hearing After Cochlear Implantation

Balkany, Thomas J., Connell, Sarah S., Hodges, Annelle V., Payne, Stacy L., Telischi, Fred F., Eshraghi, Adrien A., Angeli, Simon I., Germani, Ross, Messiah, Sarah, Arheart, Kristopher L. · 2006 · Otology & Neurotology
Cited by 176

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: This study was designed to test the hypothesis that partial hearing conservation is attainable after cochlear implantation with a long perimodiolar electrode. Surgical strategies for hearing conservation during cochlear implantation are described. STUDY DESIGN: Prospective, single-subject, repeated-measures design. SETTING: Academic tertiary care center. PATIENTS: Twenty-eight severely to profoundly hearing-impaired adult cochlear implant recipients who had some measurable hearing preoperatively. INTERVENTION: Cochlear implantation using Nucleus Freedom Contour Advance electrode. MAIN OUTCOME MEASURES: Preimplant and postimplant pure-tone thresholds and speech recognition scores were obtained to determine the incidence and degree of conserved hearing at a mean interval of 9 (+/-3.9) months. RESULTS: Thirty-two percent of subjects experienced complete conservation of hearing (0- to 10-dB loss), and 57% experienced partial conservation of hearing (>11 dB) after implantation. However, open-set speech recognition was partially conserved in only one subject. Cochlear implant performance was not better in patients with conservation of residual hearing. CONCLUSION: Conservation of pure-tone hearing was possible in 89% of implanted patients; however, residual speech perception was not conserved with this long perimodiolar electrode. A ceiling effect tends to inflate the prevalence of hearing conservation in implantation studies of severely to profoundly hearing-impaired patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.mao.0000244355.34577.85

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 176

Metadata

Authors
Balkany, T. J., Connell, S. S., Hodges, A. V., Payne, S. L., Telischi, F. F., Eshraghi, A. A., Angeli, S. I., Germani, R., Messiah, S., & Arheart, K. L.
Venue
Otology & Neurotology
Published
2006-12
Volume
27
Issue
8
Pages
1083-1088
ISSN
1531-7129 (ISSN-L)
OpenAlex
W2058229310
Cited by
176
References
7
FWCI
2.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Conservation of Residual Acoustic Hearing After Cochlear Implantation. https://app.cochat.ai/papers/10.1097/01.mao.0000244355.34577.85
The paper
Balkany, T. J., Connell, S. S., Hodges, A. V., Payne, S. L., Telischi, F. F., Eshraghi, A. A., Angeli, S. I., Germani, R., Messiah, S., & Arheart, K. L. (2006). Conservation of Residual Acoustic Hearing After Cochlear Implantation. Otology & Neurotology. https://doi.org/10.1097/01.mao.0000244355.34577.85

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.