The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Multi-centre investigation on reference ranges for ROTEM thromboelastometry
Abstract
Reagent-supported thromboelastometry (TEM) with the ROTEM Whole Blood Haemostasis Analyser is an enhancement of thromboelastography, a method that is increasingly used for the point of care monitoring of acute perioperative bleeding disorders. We investigated the reference ranges of two activated tests (INTEM and EXTEM) and a test analysing specifically the fibrin component of coagulation (FIBTEM) in a multi-centre approach. The reference ranges obtained for the clotting time (CT), clot formation time (CFT), alpha angle (ALP), maximum clot firmness (MCF) and clot lysis parameters were comparable from centre to centre. INTEM: CT equals; 137-246 s, CFT equals; 40-100 s, MCF equals; 52-72 mm. EXTEM: CT equals; 42-74 s, CFT equals; 46-148 s, MCF equals; 49-71 mm. FIBTEM: MCF equals; 9-25 mm. ROTEM whole blood coagulation correlated weakly with a trend towards enhanced coagulation in females compared with males and in advanced age. The repeatability (within-run imprecision) of the results was dependent on the test with the following coefficients of variation: 1-5% (clot firmness, alpha angle), 3-12% (CT, CFT), 6-13% (FIBTEM clot firmness). Citrated blood samples were stable for ROTEM analysis stored within 6 h from drawing. In summary, the data showed that ROTEM thromboelastometry yields consistent values between centres and that providing general orientating reference ranges seems to be possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thromboelastography-Guided Transfusion Algorithm Reduces Transfusions in Complex Cardiac Surgery
Shore-Lesserson, L., Manspeizer, H. E., DePerio, M., Francis, S., Vela-Cantos, F., & Ergin, M. A. (1999) · Anesthesia & Analgesia · doi:10.1097/00000539-199902000-00016 · Cited by 845
Kang, Y. G., Martin, D. J., Marquez, J., Lewis, J. H., Bontempo, F. A., Shaw, B. W., Starzl, T. E., & Winter, P. M. (1985) · Anesthesia & Analgesia · doi:10.1213/00000539-198509000-00008 · Cited by 684
Blutgerinnungsstudien mit der Thrombelastographie, einem neuen Untersuchungsverfahren
Hartert, H. (1948) · Klinische Wochenschrift · doi:10.1007/bf01697545 · Cited by 615
Whole blood coagulation thrombelastographic profiles employing minimal tissue factor activation
Sørensen, B., Johansen, P., Christiansen, K., Woelke, M., & Ingerslev, J. (2003) · Journal of Thrombosis and Haemostasis · doi:10.1046/j.1538-7836.2003.00075.x · Cited by 352
Usefulness of Thrombelastography in Assessment of Trauma Patient Coagulation
Kaufmann, C. R., Dwyer, K. M., Crews, J. D., Dols, S. J., & Trask, A. L. (1997) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199704000-00023 · Cited by 351
Spiess, B. D., Gillies, B. S. A., Chandler, W., & Verrier, E. (1995) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80189-2 · Cited by 280
Royston, D., & von Kier, S. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/86.4.575 · Cited by 237
Cammerer, U., Dietrich, W., Rampf, T., Braun, S. L., & Richter, J. A. (2003) · Anesthesia & Analgesia · doi:10.1097/00000539-200301000-00011 · Cited by 224
Self-citationWoodward, M., Lowe, G. D. O., Rumley, A., Tunstall‐Pedoe, H., Philippou, H., Lane, D. A., & Morrison, C. E. (1997) · British Journal of Haematology · doi:10.1046/j.1365-2141.1997.1232935.x · Cited by 156
Anderson, L., Quasim, I., Soutar, R. L., Steven, M., Macfie, A., & Korte, W. C. (2006) · Transfusion Medicine · doi:10.1111/j.1365-3148.2006.00645.x · Cited by 153
Cited by
Ganter, M. T., & Hofer, C. K. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318168b367 · Cited by 677
The incidence and magnitude of fibrinolytic activation in trauma patients
RAZA, I., DAVENPORT, R., ROURKE, C., PLATTON, S., MANSON, J., SPOORS, C., KHAN, S., De'ATH, H. D., ALLARD, S., HART, D. P., et al. (2013) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12078 · Cited by 481
Schöchl, H., Frietsch, T., Pavelka, M., & Jámbor, C. (2009) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e31818b2483 · Cited by 393
Haas, T., Spielmann, N., Mauch, J., Madjdpour, C., Speer, O., Schmugge, M., & Weiss, M. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aer342 · Cited by 335
Evaluation of rotation thrombelastography for the diagnosis of hyperfibrinolysis in trauma patients
Levrat, A., Gros, A., Rugeri, L., Inaba, K., Floccard, B., Negrier, C., & David, J.-S. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen083 · Cited by 331
Metadata
- Authors
- Lang, T., Bauters, A., Braun, S. L., Pötzsch, B., von Pape, K.-W., Kolde, H.-J., & Lakner, M.
- Venue
- Blood Coagulation & Fibrinolysis
- Published
- 2005-06
- Volume
- 16
- Issue
- 4
- Pages
- 301-310
- ISSN
- 0957-5235 (ISSN-L)
- OpenAlex
- W2134477676
- Cited by
- 503
- References
- 17
- FWCI
- 7.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multi-centre investigation on reference ranges for ROTEM thromboelastometry. https://app.cochat.ai/papers/10.1097/01.mbc.0000169225.31173.19
- The paper
- Lang, T., Bauters, A., Braun, S. L., Pötzsch, B., von Pape, K.-W., Kolde, H.-J., & Lakner, M. (2005). Multi-centre investigation on reference ranges for ROTEM thromboelastometry. Blood Coagulation & Fibrinolysis. https://doi.org/10.1097/01.mbc.0000169225.31173.19
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.