CoChat

Air-displacement plethysmography: here to stay

Fields, David A, Higgins, Paul B, Radley, Duncan · 2005 · Current Opinion in Clinical Nutrition & Metabolic Care
Cited by 77

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE OF REVIEW: Air-displacement plethysmography holds promise as an alternative to more traditional body composition techniques, although our understanding of air-displacement plethysmography is less than complete. Specifically, factors that influence its validity and application in certain populations, for example children, the obese, and athletes, must be better understood. This review will summarize recent findings on the validity and precision of air-displacement plethysmography and will focus primarily on papers published since 2004, with particular attention on its use in infants. RECENT FINDINGS: The most significant recent findings in the air-displacement plethysmography literature are mechanistic in nature specifically dealing with measurement issues such as heat, moisture, clothing, and recently, inter-device variability. SUMMARY: It is important to recognize that air-displacement plethysmography can be a practical instrument in the evaluation of body composition in a wide range of populations. Therefore, based on the body of literature that has emerged, air-displacement plethysmography appears to be a suitable and reliable instrument in the assessment of body composition. Of particular interest is its use in pediatric and obese individuals, areas requiring further study. Research is also needed to help us better understand sources of measurement error.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.mco.0000171127.44525.07

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 77

Metadata

Authors
Fields, D. A., Higgins, P. B., & Radley, D.
Venue
Current Opinion in Clinical Nutrition & Metabolic Care
Published
2005-11
Volume
8
Issue
6
Pages
624-629
ISSN
1363-1950 (ISSN-L)
OpenAlex
W1991815531
Cited by
77
References
4
FWCI
2.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Air-displacement plethysmography: here to stay. https://app.cochat.ai/papers/10.1097/01.mco.0000171127.44525.07
The paper
Fields, D. A., Higgins, P. B., & Radley, D. (2005). Air-displacement plethysmography: here to stay. Current Opinion in Clinical Nutrition & Metabolic Care. https://doi.org/10.1097/01.mco.0000171127.44525.07

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.