Cited by 678Body Composition Measurement TechniquesBody Contouring and SurgeryNon-Invasive Vital Sign Monitoring

A new air displacement method for the determination of human body composition

DEMPSTER, PHILIP, AITKENS, SUSAN·1995·Medicine & Science in Sports & Exercise

Abstract

A new device based on the plethysmographic measurement of body volume has been developed for the purpose of estimating human body composition. The device, the BOD POD Body Composition System, uses the relationship between pressure and volume to derive the body volume of a subject seated inside a fiberglass chamber. Derivation of body volume, together with measurement of body mass, permits calculation of body density and subsequent estimation of percent fat and fat-free mass. Critical issues which have hampered prior plethysmographic approaches are discussed. The present system's ability to measure the volume of inanimate objects was evaluated for accuracy, reliability, and linearity. Twenty successive tests of a known volume (50,039 ml) on two separate days produced values of 50,037 +/- 12.7 ml and 50,030 +/- 13.5 ml (mean +/- SD) for each day, respectively. The CV for these series were 0.025% and 0.027%. Further testing across a wide range of volumes approximating human size (25-150 1) produced the following regression equation where y = measured volume (1) and x = actual volume (1): y = 0.9998x - 0.0274, r2 = 1.0, SEE = 0.004 1. The resultant device is likely to enhance opportunities for the quick, simple and noninvasive measurement of body composition for both research and clinical applications.

Integrity signals

Registry

Crossref · 10.1249/00005768-199512000-00017

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
DEMPSTER, P., & AITKENS, S.
Venue
Medicine & Science in Sports & Exercise
Published
1995-12
Volume
27
Issue
12
Pages
1692???1697
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2046886748
Cited by
678
References
0
Citations by year
2026: 13 · 2025: 21 · 2024: 16 · 2023: 17 · 2022: 18 · 2021: 28 · 2020: 29 · 2019: 23 · 2018: 23 · 2017: 21 · 2016: 26 · 2015: 32 · 2014: 30 · 2013: 33 · 2012: 26
FWCI
2.22
Type
journal article
Language
en
Open access
closed
Locations
  • Medicine & Science in Sports & Exercise (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (2r44dk042396-02, 1r43dk042396-01)
  • National Institute of Diabetes and Digestive and Kidney Diseases (R44DK42396, R43DK42396)
Topics
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Health Sciences › Medicine › Surgery › Body Contouring and Surgery
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
body composition, air displacement plethysmography, BOD POD, body volume measurement, body density, fat-free mass, pressure-volume relationship, measurement accuracy and reliability
MeSH terms
Adipose Tissue, Air, Body Composition, Body Constitution, Body Weight, Equipment Design, Glass, Humans, Plethysmography, Pressure, Regression Analysis, Signal Processing, Computer-Assisted, Reproducibility of Results, Body Mass Index, Linear Models

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review