Indirect calorimetry: methodology, instruments and clinical application
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: This review aims to identify the basic methods for accurately measuring a patient's energy expenditure in clinical nutrition practice by indirect calorimetry, and the impact upon a disease state of applying the results obtained. RECENT FINDINGS: The open-circuit method is the most widely used in the majority of classical instruments for measuring energy consumption. Advances in gas exchange measurement have made this technique readily and precisely available at the bedside. Nevertheless, it is important to understand its intricate primary methodology for safe and correct application. The stress and activity factors should be carefully and specifically applied, and the respiratory quotient abandoned, for tailoring a patient's daily nutrition regimens. Caloric expenditure measured by indirect calorimetry coupled with the doubly labeled water technique introduced the concept of physical activity energy expenditure, which added to resting energy expenditure results in total daily energy expenditure. Compact modular and handheld devices have been introduced into the market, together with similar technology for evaluating exercise energy expenditure, making utilization easier, safer and precise. In the critically ill population, which is exposed to medical and surgical interventions, indirect calorimetry has greatly changed the practice of caloric administration, significantly reducing the total daily amount. SUMMARY: In conclusion, one has to be careful when choosing devices, and understanding and clinically applying the results obtained by indirect calorimetry, bearing in mind that measured resting energy expenditure should be the daily caloric goal in order to diminish clinical morbidity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of substrate oxidation during exercise by means of gas exchange measurements
Jeukendrup, A. E., & Wallis, G. A. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-830512 · Cited by 799
Uehara, M., Plank, L. D., & Hill, G. L. (1999) · Critical Care Medicine · doi:10.1097/00003246-199907000-00015 · Cited by 203
The Measurement of Energy Expenditure
Branson, R. D., & Johannigman, J. A. (2004) · Nutrition in Clinical Practice · doi:10.1177/0115426504019006622 · Cited by 111
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Badjatia, N., Strongilis, E., Gordon, E., Prescutti, M., Fernandez, L., Fernandez, A., Buitrago, M., Schmidt, J. M., Ostapkovich, N. D., & Mayer, S. A. (2008) · Stroke · doi:10.1161/strokeaha.108.523654 · Cited by 334
Bandín, C., Scheer, F. A. J. L., Luque, A. J., Ávila-Gandía, V, Zamora, S., Madrid, J. A., Gómez-Abellán, P., & Garaulet, M. (2015) · International Journal of Obesity · doi:10.1038/ijo.2014.182 · Cited by 262
Bo, S., Fadda, M., Castiglione, A., Ciccone, G., De Francesco, A., Fedele, D., Guggino, A., Parasiliti Caprino, M., Ferrara, S., Vezio Boggio, M., et al. (2015) · International Journal of Obesity · doi:10.1038/ijo.2015.138 · Cited by 171
Simonen, M., Dali-Youcef, N., Kaminska, D., Venesmaa, S., Käkelä, P., Pääkkönen, M., Hallikainen, M., Kolehmainen, M., Uusitupa, M., Moilanen, L., et al. (2012) · Obesity Surgery · doi:10.1007/s11695-012-0673-5 · Cited by 145
Metadata
- Authors
- da Rocha, E. E. M., Alves, V. G. F., & da Fonseca, R. B. V.
- Venue
- Current Opinion in Clinical Nutrition and Metabolic Care
- Published
- 2006-05
- Volume
- 9
- Issue
- 3
- Pages
- 247-256
- ISSN
- 1363-1950 (ISSN-L)
- OpenAlex
- W2060544079
- Cited by
- 177
- References
- 3
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Indirect calorimetry: methodology, instruments and clinical application. https://app.cochat.ai/papers/10.1097/01.mco.0000222107.15548.f5
- The paper
- da Rocha, E. E. M., Alves, V. G. F., & da Fonseca, R. B. V. (2006). Indirect calorimetry: methodology, instruments and clinical application. Current Opinion in Clinical Nutrition and Metabolic Care. https://doi.org/10.1097/01.mco.0000222107.15548.f5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.