Indirect calorimetry: methodology, instruments and clinical application
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: This review aims to identify the basic methods for accurately measuring a patient's energy expenditure in clinical nutrition practice by indirect calorimetry, and the impact upon a disease state of applying the results obtained. RECENT FINDINGS: The open-circuit method is the most widely used in the majority of classical instruments for measuring energy consumption. Advances in gas exchange measurement have made this technique readily and precisely available at the bedside. Nevertheless, it is important to understand its intricate primary methodology for safe and correct application. The stress and activity factors should be carefully and specifically applied, and the respiratory quotient abandoned, for tailoring a patient's daily nutrition regimens. Caloric expenditure measured by indirect calorimetry coupled with the doubly labeled water technique introduced the concept of physical activity energy expenditure, which added to resting energy expenditure results in total daily energy expenditure. Compact modular and handheld devices have been introduced into the market, together with similar technology for evaluating exercise energy expenditure, making utilization easier, safer and precise. In the critically ill population, which is exposed to medical and surgical interventions, indirect calorimetry has greatly changed the practice of caloric administration, significantly reducing the total daily amount. SUMMARY: In conclusion, one has to be careful when choosing devices, and understanding and clinically applying the results obtained by indirect calorimetry, bearing in mind that measured resting energy expenditure should be the daily caloric goal in order to diminish clinical morbidity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,603
The theoretical bases of indirect calorimetry: A review
Ferrannini, E. (1988) · Metabolism · doi:10.1016/0026-0495(88)90110-2 · Cited by 1,580
Measurement of substrate oxidation during exercise by means of gas exchange measurements
Jeukendrup, A. E., & Wallis, G. A. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-830512 · Cited by 799
Kumahara, H., Schutz, Y., Ayabe, M., Yoshioka, M., Yoshitake, Y., Shindo, M., Ishii, K., & Tanaka, H. (2004) · British Journal of Nutrition · doi:10.1079/bjn20031033 · Cited by 534
Measurement of gas exchange in intensive care: Laboratory and clinical validation of a new device
TAKALA, J., KEINÄNEN, O., VÄISÄNEN, P., & KARI, A. (1989) · Critical Care Medicine · doi:10.1097/00003246-198910000-00015 · Cited by 303
Clinical use of the respiratory quotient obtained from indirect calorimetry
McClave, S., Lowen, C., Kleber, M., McConnell, J., Jung, L., & Goldsmith, L. (2003) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/014860710302700121 · Cited by 239
Uehara, M., Plank, L. D., & Hill, G. L. (1999) · Critical Care Medicine · doi:10.1097/00003246-199907000-00015 · Cited by 203
Invited Review: Use of Indirect Calorimetry in Clinical Nutrition
McClave, S. A., & Snider, H. L. (1992) · Nutrition in Clinical Practice · doi:10.1177/0115426592007005207 · Cited by 195
Variability of measured resting metabolic rate
Haugen, H. A., Melanson, E. L., Tran, Z. V., Kearney, J. T., & Hill, J. O. (2003) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/78.6.1141 · Cited by 177
Are Patients Fed Appropriately According to Their Caloric Requirements?
McClave, S. A., Lowen, C. C., Kleber, M. J., Nicholson, J. F., Jimmerson, S. C., McConnell, J. W., & Jung, L. Y. (1998) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607198022006375 · Cited by 164
Achievement of steady state optimizes results when performing indirect calorimetry
McClave, S., Spain, D. A., Skolnick, J. L., Lowen, C. C., Kleber, M., Wickerham, P., Vogt, J., & Looney, S. W. (2003) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/014860710302700116 · Cited by 156
Indirect calorimetry in critically Ill patients: Clinical applications and practical advice*1
Brandi, L. S., Bertolini, R., & Calafà, M. (1997) · Nutrition · doi:10.1016/s0899-9007(97)00074-9 · Cited by 138
A new handheld device for measuring resting metabolic rate and oxygen consumption
Nieman, D. C., TRONE, G. A., & Austin, M. D. (2003) · Journal of the American Dietetic Association · doi:10.1053/jada.2003.50116 · Cited by 114
The Measurement of Energy Expenditure
Branson, R. D., & Johannigman, J. A. (2004) · Nutrition in Clinical Practice · doi:10.1177/0115426504019006622 · Cited by 111
Lower resting metabolic rate in the elderly may not be entirely due to changes in body composition
Krems, C., Lührmann, P. M., Straßburg, A., Hartmann, B., & Neuhäuser‐Berthold, M. (2004) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602066 · Cited by 105
Isbell, T. R., Klesges, R. C., Meyers, A. W., & Klesges, L. M. (1991) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607191015002165 · Cited by 104
da Rocha, E. E. M., Alves, V. G. F., Silva, M. H. D. N., Chiesa, C. A., & da Fonseca, R. B. V. (2005) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/01.mco.0000165012.77567.1e · Cited by 101
Self-citationHoldy, K. E. (2004) · Nutrition in Clinical Practice · doi:10.1177/0115426504019005447 · Cited by 97
Haman, F., Péronnet, F., Kenny, G. P., Massicotte, D., Lavoie, C., & Weber, J. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.086272 · Cited by 96
Reeves, M. M., Davies, P. S. W., Bauer, J., & Battistutta, D. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01212.2003 · Cited by 95
Equations for predicting the energy requirements of healthy adults aged 18–81 y
Vinken, A. G., Bathalon, G. P., Sawaya, A. L., Dallal, G. E., Tucker, K. L., & Roberts, S. B. (1999) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/69.5.920 · Cited by 92
Nutritional requirements of surgical and critically-ill patients: do we really know what they need?
Reid, C. L. (2004) · Proceedings of The Nutrition Society · doi:10.1079/pns2004312 · Cited by 92
In vitro evaluation of a compact metabolic measurement instrument
Weissman, C., Sardar, A., & Kemper, M. (1990) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607190014002216 · Cited by 78
Calculation versus measurement of total energy expenditure
B. VAN LANSCHOT, J. J., FEENSTRA, B. W. A., VERMEIJ, C. G., & BRUINING, H. A. (1986) · Critical Care Medicine · doi:10.1097/00003246-198611000-00015 · Cited by 70
Hustvedt, B.-E., Christophersen, A., Johnsen, L. R., Tomten, H., McNeill, G., Haggarty, P., & Løvø, A. (2004) · British Journal of Nutrition · doi:10.1079/bjn20041272 · Cited by 69
Comparison between Medgem and Deltatrac resting metabolic rate measurements
Compher, C. W., Hise, M. E., Sternberg, A., & Kinosian, B. P. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602223 · Cited by 65
Frankenfield, D. C., Sarson, G. Y., Blosser, S. A., Cooney, R. N., & Smith, J. S. (1996) · Journal of the American College of Nutrition · doi:10.1080/07315724.1996.10718615 · Cited by 64
McLellan, S. A., Walsh, T. S., Burdess, A., & Lee, A. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1323-5 · Cited by 63
A New Hand‐Held Indirect Calorimeter to Measure Postprandial Energy Expenditure
St‐Onge, M., Rubiano, F., Jones, A., & Heymsfield, S. B. (2004) · Obesity Research · doi:10.1038/oby.2004.82 · Cited by 62
Indirect Calorimetry: Applications to Practice
Wooley, J. A., & Sax, H. C. (2003) · Nutrition in Clinical Practice · doi:10.1177/0115426503018005434 · Cited by 62
Validation of the BodyGem™ hand-held calorimeter
Melanson, E. L., Coelho, L. B., Tran, Z. V., Haugen, H. A., Kearney, J. T., & Hill, J. O. (2004) · International Journal of Obesity · doi:10.1038/sj.ijo.0802643 · Cited by 62
Reeves, M. M., Capra, S. M., Bauer, J. D., Davies, P., & Battistutta, D. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602114 · Cited by 58
Alam, D. S., Hulshof, P. J. M., Roordink, D., Meltzer, M., Yunus, M., Salam, M. A., & Raaij, J. M. A. V. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602122 · Cited by 47
Obesity: Nutrition Support Practice and Application to Critical Care
Ireton-Jones, C. S., & Francis, C. C. (1995) · Nutrition in Clinical Practice · doi:10.1177/0115426595010004144 · Cited by 46
Nieman, D. C., Austin, M. D., Chilcote, S. M., & Benezra, L. (2005) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.15.2.186 · Cited by 42
Calculation of Metabolic Expenditure and Substrate Utilization from Gas Exchange Measurements
Westenskow, D. R., Schipke, C. A., Raymond, J. L., Saffle, J. R., Becker, J. M., Young, E. W., & Cutler, C. A. (1988) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/014860718801200120 · Cited by 40
Comparison of Gas Exchange Measurements With a Mouthpiece, Face Mask, and Ventilated Canopy
Forse, R. A. (1993) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607193017004388 · Cited by 39
Comparison of Methods for Achieving 24‐Hour Energy Balance in a Whole‐Room Indirect Calorimeter
Grunwald, G. K., Melanson, E. L., Forster, J. E., SEAGLE, H. M., Sharp, T. A., & Hill, J. O. (2003) · Obesity Research · doi:10.1038/oby.2003.105 · Cited by 33
Headley, J. M. (2003) · AACN Clinical Issues Advanced Practice in Acute & Critical Care · doi:10.1097/00044067-200305000-00005 · Cited by 33
Methods of Assessing Energy Expenditure in the Intensive Care Unit
Malone, A. M. (2002) · Nutrition in Clinical Practice · doi:10.1177/011542650201700121 · Cited by 25
Energy expenditure in wasting diseases: current concepts and measurement techniques
Toth, M. J. (1999) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/00075197-199911000-00003 · Cited by 14
Working capacity and resting energy expenditure after ileal pouch–anal anastomosis
Öhrström, M., Jansson, O., Wohlfart, B., & Ekelund, M. (2004) · British journal of surgery · doi:10.1002/bjs.4519 · Cited by 10
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Badjatia, N., Strongilis, E., Gordon, E., Prescutti, M., Fernandez, L., Fernandez, A., Buitrago, M., Schmidt, J. M., Ostapkovich, N. D., & Mayer, S. A. (2008) · Stroke · doi:10.1161/strokeaha.108.523654 · Cited by 334
Bandín, C., Scheer, F. A. J. L., Luque, A. J., Ávila-Gandía, V, Zamora, S., Madrid, J. A., Gómez-Abellán, P., & Garaulet, M. (2015) · International Journal of Obesity · doi:10.1038/ijo.2014.182 · Cited by 262
Bo, S., Fadda, M., Castiglione, A., Ciccone, G., De Francesco, A., Fedele, D., Guggino, A., Parasiliti Caprino, M., Ferrara, S., Vezio Boggio, M., et al. (2015) · International Journal of Obesity · doi:10.1038/ijo.2015.138 · Cited by 171
Simonen, M., Dali-Youcef, N., Kaminska, D., Venesmaa, S., Käkelä, P., Pääkkönen, M., Hallikainen, M., Kolehmainen, M., Uusitupa, M., Moilanen, L., et al. (2012) · Obesity Surgery · doi:10.1007/s11695-012-0673-5 · Cited by 145
“VO2 and VCO2 were used to determine endogenous metabolism of lipids and carbohydrates in the fasting state [25].”
Method
Metadata
- Authors
- da Rocha, E. E. M., Alves, V. G. F., & da Fonseca, R. B. V.
- Venue
- Current Opinion in Clinical Nutrition and Metabolic Care
- Published
- 2006-05
- Volume
- 9
- Issue
- 3
- Pages
- 247-256
- ISSN
- 1363-1950 (ISSN-L)
- OpenAlex
- W2060544079
- Cited by
- 177
- References
- 42
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.