Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 224

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Diagnostic Tests in Hirschsprung Disease: A Systematic Review

de Lorijn, F., Kremer, L.C.M., Reitsma, J.B., Benninga, M.A. · 2006 · Journal of Pediatric Gastroenterology and Nutrition

Abstract

Objective: We conducted a systematic review to determine and compare the diagnostic accuracy of contrast enema (CE), anorectal manometry (ARM) and rectal suction biopsy (RSB) in infants suspected of Hirschsprung disease. Design: This is a systematic review. Data Sources: Articles were identified through electronic searches in Medline, EMBASE.com and Cochrane Controlled Trials Register. Searches were limited to articles published after 1966 in PubMed and after 1980 in EMBASE.com. Study Selection: Studies were included if infants underwent at least one of the following tests: CE, ARM or RSB, followed by full‐thickness biopsy and/or clinical follow‐up as the reference standard. Data Extraction: Two reviewers independently assessed the methods of data collection, patient selection, blinding and prevention of verification bias and description of the test protocol and reference standard. Data to construct 2 × 2 tables were abstracted for each test. Results: Twenty‐four studies met our inclusion criteria, but 2 studies were subsequently excluded for statistical analysis because data was missing to construct the 2 × 2 table. RSB (14 studies for a total of 993 patients) was the most accurate test, having both the highest mean sensitivity (93%; 95% confidence interval [CI], 88%‐95%) and mean specificity (98%; 95% CI, 95%‐99%). Sensitivity and specificity of ARM (9 studies for a total of 400 patients) were similar to those of RSB (91% vs 93%, P = 0.73 and 94% vs 98%, P = 0.08, respectively). Sensitivity and specificity of CE (12 studies for a total of 425 patients) were significantly lower than those of RSB and ARM, with mean sensitivity and mean specificity of 70% and 83%, respectively. Conclusions: RSB and ARM are the most accurate tests in the diagnostic workup of Hirschsprung disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.mpg.0000214164.90939.92

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 224

Metadata

Authors
de Lorijn, F., Kremer, L. C. M., Reitsma, J. B., & Benninga, M. A.
Venue
Journal of Pediatric Gastroenterology and Nutrition
Publisher
Wiley
Published
2006-05
Volume
42
Issue
5
Pages
496-505
ISSN
  • 0277-2116 (ISSN-L)
  • 1536-4801
OpenAlex
W2026143005
Cited by
224
References
2
FWCI
6.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Tests in Hirschsprung Disease: A Systematic Review. https://app.cochat.ai/papers/10.1097/01.mpg.0000214164.90939.92
The paper
de Lorijn, F., Kremer, L. C. M., Reitsma, J. B., & Benninga, M. A. (2006). Diagnostic Tests in Hirschsprung Disease: A Systematic Review. Journal of Pediatric Gastroenterology and Nutrition. https://doi.org/10.1097/01.mpg.0000214164.90939.92

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.