Diagnostic Tests in Hirschsprung Disease: A Systematic Review
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Objective: We conducted a systematic review to determine and compare the diagnostic accuracy of contrast enema (CE), anorectal manometry (ARM) and rectal suction biopsy (RSB) in infants suspected of Hirschsprung disease. Design: This is a systematic review. Data Sources: Articles were identified through electronic searches in Medline, EMBASE.com and Cochrane Controlled Trials Register. Searches were limited to articles published after 1966 in PubMed and after 1980 in EMBASE.com. Study Selection: Studies were included if infants underwent at least one of the following tests: CE, ARM or RSB, followed by full‐thickness biopsy and/or clinical follow‐up as the reference standard. Data Extraction: Two reviewers independently assessed the methods of data collection, patient selection, blinding and prevention of verification bias and description of the test protocol and reference standard. Data to construct 2 × 2 tables were abstracted for each test. Results: Twenty‐four studies met our inclusion criteria, but 2 studies were subsequently excluded for statistical analysis because data was missing to construct the 2 × 2 table. RSB (14 studies for a total of 993 patients) was the most accurate test, having both the highest mean sensitivity (93%; 95% confidence interval [CI], 88%‐95%) and mean specificity (98%; 95% CI, 95%‐99%). Sensitivity and specificity of ARM (9 studies for a total of 400 patients) were similar to those of RSB (91% vs 93%, P = 0.73 and 94% vs 98%, P = 0.08, respectively). Sensitivity and specificity of CE (12 studies for a total of 425 patients) were significantly lower than those of RSB and ARM, with mean sensitivity and mean specificity of 70% and 83%, respectively. Conclusions: RSB and ARM are the most accurate tests in the diagnostic workup of Hirschsprung disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advanced methods in meta‐analysis: multivariate approach and meta‐regression
van Houwelingen, H. C., Arends, L. R., & Stijnen, T. (2002) · Statistics in Medicine · doi:10.1002/sim.1040 · Cited by 1,580 · cited 1×
“We used a bivariate metaregression model to meta-analyse the estimates of sensitivity and specificity (10,11).”
MethodThe STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124 · cited 1×
“) independently assessed the design of the study, blinding and prevention of verification bias, methods of data collection and patient characteristics (9).”
MethodSelf-citationChronic constipation in children
Loening-Baucke, V. (1993) · Gastroenterology · doi:10.1016/0016-5085(93)90166-a · Cited by 330
A bivariate approach to meta-analysis
Van Houwelingen, H. C., Zwinderman, K. H., & Stijnen, T. (1993) · Statistics in Medicine · doi:10.1002/sim.4780122405 · Cited by 327 · cited 1×
“We used a bivariate metaregression model to meta-analyse the estimates of sensitivity and specificity (10,11).”
MethodHirschsprung disease: accuracy of the barium enema examination.
Rosenfield, N. S., Ablow, R. C., Markowitz, R. I., DiPietro, M., Seashore, J. H., Touloukian, R. J., & Cicchetti, D. (1984) · Radiology · doi:10.1148/radiology.150.2.6691093 · Cited by 112 · cited 1×
“(17) described 4 newborn infants with a meconium plug syndrome leading to a transition zone at the splenic flexure, mimicking the finding in HD.”
Background
Cited by
Hirschsprung disease — integrating basic science and clinical medicine to improve outcomes
Heuckeroth, R. O. (2018) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2017.149 · Cited by 304
ERNICA guidelines for the management of rectosigmoid Hirschsprung’s disease
Kyrklund, K., Sloots, C. E. J., de Blaauw, I., Bjørnland, K., Rolle, U., Cavalieri, D., Francalanci, P., Fusaro, F., Lemli, A., Schwarzer, N., et al. (2020) · Orphanet Journal of Rare Diseases · doi:10.1186/s13023-020-01362-3 · Cited by 192
“The sensitivity and specificity of other methods, including anorectal manometry and contrast enema are inferior to those of an adequate rectal biopsy, particularly in young infants [15, 16].”
MethodHow to Perform and Interpret a High-resolution Anorectal Manometry Test
Lee, T. H., & Bharucha, A. E. (2015) · Journal of Neurogastroenterology and Motility · doi:10.5056/jnm15168 · Cited by 185
“In a systematic review, the diagnostic utility of the absence of RAIR in Hirschsprung’s disease, as detected by non-HRM, had a sensitivity of 91% and specificity of 94%.(43) A recent HD-ARM study found that RAIR is characterized by a differential relaxation along the anteroposterior axis, the length of the anal canal,…”
BackgroundEmerging role of non‐coding RNA in health and disease
Bhatti, G. K., Khullar, N., Sidhu, I. S., Navik, U. S., Reddy, A. P., Reddy, P. H., & Bhatti, J. S. (2021) · Metabolic Brain Disease · doi:10.1007/s11011-021-00739-y · Cited by 181
“Hirschsprung disease (HSCR) It is a condition where a new born`s large intestine (colon) does not have proper nerve supply to the muscles of colons (abnormal cell migration of neural cells to the colon), leading to problems with passing stool, severe constipation, gas problems.”
BackgroundInfluentialDiagnosis of Hirschsprung Disease
Ambartsumyan, L., Smith, C., & Kapur, R. P. (2020) · Pediatric and Developmental Pathology · doi:10.1177/1093526619892351 · Cited by 178
“In a subgroup analysis of diagnostic accuracy of ARM in infants younger than 6 months, de Lorijn et al.(41) found overall lower sensitivity of 88% and specificity of 89% but no significant difference from the total group.”
BackgroundMethodResultInfluentialPeng, L., Chen, G., Zhu, Z., Shen, Z., Du, C., Zang, R., Su, Y., Xie, H., Li, H., Xu, X., et al. (2017) · Oncotarget · doi:10.18632/oncotarget.13656 · Cited by 174
“0051, 77% and 94%, which were even higher than the sensitivity (70%) and specificity (83%) of the most common method (contrast enema) for the assessment of children with suspected HSCR [23].”
Montalva, L., Cheng, L. S., Kapur, R., Langer, J. C., Berrebi, D., Kyrklund, K., Pakarinen, M., de Blaauw, I., Bonnard, A., & Gosain, A. (2023) · Nature Reviews Disease Primers · doi:10.1038/s41572-023-00465-y · Cited by 171
Layer, P., Andresen, V., Allescher, H., Bischoff, S. C., Claßen, M., Elsenbruch, S., Freitag, M., Frieling, T., Gebhard, M., Goebel-Stengel, M., et al. (2021) · Zeitschrift für Gastroenterologie · doi:10.1055/a-1591-4794 · Cited by 76
Metadata
- Authors
- de Lorijn, F., Kremer, L. C. M., Reitsma, J. B., & Benninga, M. A.
- Venue
- Journal of Pediatric Gastroenterology and Nutrition
- Publisher
- Wiley
- Published
- 2006-05
- Volume
- 42
- Issue
- 5
- Pages
- 496-505
- ISSN
- 0277-2116 (ISSN-L)
- 1536-4801
- OpenAlex
- W2026143005
- Cited by
- 224
- References
- 5
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.