The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Hemodynamic effects of rescue protocol hydrocortisone in neonates with low cardiac output syndrome after cardiac surgery
Abstract
Objective To assess the hemodynamic effects and safety of hydrocortisone in neonates with low cardiac output syndrome requiring high levels of inotropic support and fluid resuscitation after cardiac surgery. Design Retrospective chart review. Setting Fifteen-bed pediatric cardiovascular intensive care unit. Patients Twelve neonates with low cardiac output syndrome after cardiac surgery to whom hydrocortisone was administered according to one of two dosing regimens (100 mg/[m.day] for 2 days, 50 mg/[m.day] for 2 days, and 25 mg/[m.day] for 1 day or 100 mg/[m.day] for 1 day, 50 mg/[m.day] for 2 days, and 25 mg/[m.day] for 2 days) were identified from the Department of Pharmacy database between September 2002 and January 2004. Interventions None. Measurements and main results The mean and systolic blood pressure increased significantly 3 hrs after hydrocortisone treatment from the values preceding hydrocortisone administration. The mean blood pressure increased from 44.0+/-3.0 to 55.4+/-2.3 mm Hg (p=.01) and the systolic blood pressure increased from 64.2+/-4.7 to 78.3+/-3.4 mm Hg (p=.04). Comparable beneficial changes were also seen in the heart rate, which decreased from 168.3+/-4.6 to 148.3+/-5.6 beats/min (p=.004) after 24 hrs of hydrocortisone administration and remained at this level during the 72 hrs of follow-up. Significant weaning of epinephrine infusions was possible, from a mean dose of 0.16 to 0.06 microg/(kg.min) (p=.008), within 24 hrs after the initiation of ster…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The use of glucocorticoids for catecholamine-resistant shock in the neonatal and pediatric population is another strategy that may be of benefit, including following cardiac surgery [19-21].”
From Management of the Low Cardiac Output Syndrome Following Surgery for Congenital Heart Disease (2016) · cites this paper as [21]
Citations
Cites
Hoffman, T. M., Wernovsky, G., Atz, A. M., Kulik, T. J., Nelson, D. P., Chang, A. C., Bailey, J. M., Akbary, A., Kocsis, J. F., Kaczmarek, R., et al. (2003) · Circulation · doi:10.1161/01.cir.0000051365.81920.28 · Cited by 772 · cited 1×
“Several studies have shown that low cardiac output syndrome (LCOS) occurs in up to 25% of neonates and young children after congenital heart surgery (1).”
BackgroundSelf-citationEarly markers of major adverse events in children after cardiac operations
Duke, T., Butt, W., South, M., & Karl, T. R. (1997) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(97)70018-7 · Cited by 152
Shore, S., Nelson, D. P., Pearl, J. M., Manning, P. B., Wong, H., Shanley, T. P., Keyser, T., & Schwartz, S. M. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01751-9 · Cited by 141 · cited 3×
“In 2001, investigators reported that low-dose hydrocortisone significantly reduced inotropic requirements in children with congenital heart disease (3).”
BackgroundMethodResultInfluential
Flagged first, then by citations
Research works printed but not linked: 14
- Seri, 2001, Pediatrics, 107, 1070, 10.1542/peds.107.5.1070 · DOI
- Sassidharan, 1998, Clin Perinatol, 25, 723, 10.1016/S0095-5108(18)30108-8 · DOI
- Hatherill, 1999, Arch Dis Child, 80, 51, 10.1136/adc.80.1.51 · DOI
- Chaney, 2002, Chest, 121, 921, 10.1378/chest.121.3.921 · DOI
- Bronicki, 2000, Ann Thorac Surg, 69, 1490, 10.1016/S0003-4975(00)01082-1 · DOI
- Checchia, 2003, Crit Care Med, 31, 1742, 10.1097/01.CCM.0000063443.32874.60 · DOI
- Schroeder, 2003, Circulation, 107, 2823, 10.1161/01.CIR.0000070955.55636.25 · DOI
- Hatherill, 1997, Arch Dis Child, 77, 235, 10.1136/adc.77.3.235 · DOI
- Carcillo, 2002, Crit Care Med, 30, 1365, 10.1097/00003246-200206000-00040 · DOI
- Duggan, 1998, Br J Anaesth, 81, 468, 10.1093/bja/81.3.468 · DOI
- Hausdorff, 1990, FASEB J, 4, 2881, 10.1096/fasebj.4.11.2165947 · DOI
- Wehling, 1997, Annu Rev Physiol, 59, 365, 10.1146/annurev.physiol.59.1.365 · DOI
- Duffy, 2004, Pediatr Crit Care Med, 5, 28, 10.1097/01.PCC.0000102382.92024.04 · DOI
- Yeh, 2004, N Engl J Med, 350, 1304, 10.1056/NEJMoa032089 · DOI
Cited by
Sorted by citations
Management of the Low Cardiac Output Syndrome Following Surgery for Congenital Heart Disease
K. Chandler, H., & Kirsch, R. (2016) · Current Cardiology Reviews · doi:10.2174/1573403x12666151119164647 · Cited by 74
“The use of glucocorticoids for catecholamine-resistant shock in the neonatal and pediatric population is another strategy that may be of benefit, including following cardiac surgery [19-21].”
Background
Metadata
- Authors
- Suominen, P. K., Dickerson, H. A., Moffett, B. S., Ranta, S. O., Mott, A. R., Price, J. F., Heinle, J. S., McKenzie, E. D., Fraser, C. D., & Chang, A. C.
- Affiliations
- Helsinki University Hospital (FI)
- Baylor College of Medicine (US)
- Venue
- Pediatric Critical Care Medicine
- Published
- 2005-11
- Volume
- 6
- Issue
- 6
- Pages
- 655-659
- ISSN
- 1529-7535 (ISSN-L)
- OpenAlex
- W2056596224
- Cited by
- 67
- References
- 3
- Citations by year
- 2024: 1 · 2023: 3 · 2022: 2 · 2020: 2 · 2019: 2 · 2018: 6 · 2017: 5 · 2016: 7 · 2015: 4 · 2014: 3 · 2013: 7 · 2012: 6
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Pediatric Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Cardiovascular Conditions and Treatments
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- cortisol, low cardiac output syndrome, neonates, pediatric cardiac surgery, hemodynamic effects, inotropic support, fluid resuscitation, blood glucose, white blood cell count, corticosteroid dosing regimens, postoperative complications, cardiac arrhythmias, hypotension, hypoglycemia
- MeSH terms
- Anti-Inflammatory Agents, Blood Pressure, Cardiac Output, Low, Cardiotonic Agents, Clinical Protocols, Female, Heart Rate, Cardiac Surgical Procedures, Humans, Hydrocortisone, Infant, Newborn, Infant, Premature, Male, Retrospective Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review