The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Injectable Poly-L-Lactic Acid (Sculptra): Technical Considerations in Soft-Tissue Contouring
Abstract
Background: Poly-L-lactic acid gained U.S. Food and Drug Administration approval for use in human immunodeficiency virus–related facial lipoatrophy in August of 2004. Since that time, it has become available for use in the United States for human immunodeficiency virus facial lipoatrophy patients and for off-label uses in other areas for soft-tissue contouring. This article is intended to enumerate reconstitution, injection techniques, management, and avoidance of complications. Methods: The authors have pooled their experiences to arrive at a consensus opinion for recommendations on treatment protocols for injectable poly-L-lactic acid use. Results: This article prescribes techniques to achieve safer, consistent results while minimizing risks of complications with injectable poly-L-lactic acid. Although the product has been used widely in Europe since 1999, physicians in the United States have only recently begun to explore the uses of Sculptra as a volumizing agent in the face and the body. U.S. physicians have benefited from the European experience with this product, including early problems secondary to overaggressive use, low-volume reconstitution, higher volume injection of product at one session, and inadequate time between injection sessions. Conclusions: The authors therefore have opted for a more conservative approach in their treatment recommendations. Higher volume dilution (8 to 12 cc), fewer vials used at each session, injections placed in the subcutaneous plane without any product being placed in the dermis, adequate time between injection sessions (at least 6 weeks), and postinjection patient massage should decrease the risks and avoid the potential complications associated with poly-L-lactic acid soft-tissue augmentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Valantin, M.-A., Aubron-Olivier, C., Ghosn, J., Laglenne, E., Pauchard, M., Schoen, H., Bousquet, R., Katz, P., Costagliola, D., & Katlama, C. (2003) · AIDS · doi:10.1097/00002030-200311210-00009 · Cited by 355
Biodegradable Polymers in Medicine and Surgery
Kronenthal, R. L. (1975) · Polymers in Medicine and Surgery · doi:10.1007/978-1-4684-7744-3_9 · Cited by 148
Cited by
Adverse reactions to injectable soft tissue fillers
Requena, L., Requena, C., Christensen, L., Zimmermann, U. S., Kutzner, H., & Cerroni, L. (2011) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2010.02.064 · Cited by 338
Injectable Biomaterials for Regenerating Complex Craniofacial Tissues
Kretlow, J. D., Young, S., Klouda, L., Wong, M., & Mikos, A. G. (2009) · Advanced Materials · doi:10.1002/adma.200802009 · Cited by 302
Injectable “Skin Boosters” in Aging Skin Rejuvenation: A Current Overview
Rho, N.-K., Kim, H.-S., Kim, S.-Y., & Lee, W. (2024) · Archives of Plastic Surgery · doi:10.1055/a-2366-3436 · Cited by 50
An update review on recent skin fillers
Cheng, L.-Y., Sun, X.-M., Tang, M.-Y., Jin, R., Cui, W.-G., & Zhang, Y.-G. (2016) · Plastic and Aesthetic Research · doi:10.20517/2347-9264.2015.124 · Cited by 43
Metadata
- Authors
- Lam, S. M., Azizzadeh, B., & Graivier, M.
- Venue
- Plastic & Reconstructive Surgery
- Published
- 2006-09-01
- Volume
- 118
- Issue
- 3S
- Pages
- 55S-63S
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2026580010
- Cited by
- 165
- References
- 2
- FWCI
- 9.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Injectable Poly-L-Lactic Acid (Sculptra): Technical Considerations in Soft-Tissue Contouring. https://app.cochat.ai/papers/10.1097/01.prs.0000234612.20611.5a
- The paper
- Lam, S. M., Azizzadeh, B., & Graivier, M. (2006). Injectable Poly-L-Lactic Acid (Sculptra): Technical Considerations in Soft-Tissue Contouring. Plastic & Reconstructive Surgery. https://doi.org/10.1097/01.prs.0000234612.20611.5a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.