The DOI matches its Crossref record.
Does Ultra-Low-Dose CT With a Radiation Dose Equivalent to That of KUB Suffice to Detect Renal and Ureteral Calculi?
Abstract
The objective of this study was to evaluate the diagnostic yield of multislice CT using a radiation dose equivalent to that of conventional abdominal x-ray (KUB). One hundred forty-two patients were prospectively examined with ultrasound and a radically dose-reduced CT protocol (120 kV, 6.9 eff. mAs). Number and size of calculi, presence of urinary obstruction, and alternative diagnoses were recorded and confirmed by stone removal/discharge or by clinical and imaging follow-up. The mean effective whole-body dose was 0.5 mSv in men and 0.7 mSv in women. The sensitivity and specificity in detecting patients with calculi was 97% and 95% for CT and 67% and 90% for ultrasound. Urinary obstruction was similarly assessed, whereas CT identified significantly more alternative diagnoses than ultrasound (P<0.001). With regard to published data for standard-dose CT, the present CT protocol seems to be comparable in its diagnostic yield in assessing patients with calculi, and its radiation dose is equivalent to that of KUB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dual energy CT: preliminary observations and potential clinical applications in the abdomen
Graser, A., Johnson, T. R. C., Chandarana, H., & Macari, M. (2009) · European Radiology · doi:10.1007/s00330-008-1122-7 · Cited by 479
Low-Dose Versus Standard-Dose CT Protocol in Patients with Clinically Suspected Renal Colic
Poletti, P.-A., Platon, A., Rutschmann, O. T., Schmidlin, F. R., Iselin, C. E., & Becker, C. D. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0793 · Cited by 371
Dual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience
Graser, A., Johnson, T. R. C., Bader, M., Staehler, M., Haseke, N., Nikolaou, K., Reiser, M. F., Stief, C. G., & Becker, C. R. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e318157a144 · Cited by 341
Diagnostic Performance of Low-Dose CT for the Detection of Urolithiasis: A Meta-Analysis
Niemann, T., Kollmann, T., & Bongartz, G. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3414 · Cited by 296
Moore, C. L., Bomann, S., Daniels, B., Luty, S., Molinaro, A., Singh, D., & Gross, C. P. (2014) · BMJ · doi:10.1136/bmj.g2191 · Cited by 157
Metadata
- Authors
- Kluner, C., Hein, P. A., Gralla, O., Hein, E., Hamm, B., Romano, V., & Rogalla, P.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 2006-01
- Volume
- 30
- Issue
- 1
- Pages
- 44-50
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1994354011
- Cited by
- 171
- References
- 0
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Does Ultra-Low-Dose CT With a Radiation Dose Equivalent to That of KUB Suffice to Detect Renal and Ureteral Calculi? https://app.cochat.ai/papers/10.1097/01.rct.0000191685.58838.ef
- The paper
- Kluner, C., Hein, P. A., Gralla, O., Hein, E., Hamm, B., Romano, V., & Rogalla, P. (2006). Does Ultra-Low-Dose CT With a Radiation Dose Equivalent to That of KUB Suffice to Detect Renal and Ureteral Calculi? Journal of Computer Assisted Tomography. https://doi.org/10.1097/01.rct.0000191685.58838.ef
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.