High-Resolution Three-Dimensional Contrast-Enhanced Blood Oxygenation Level-Dependent Magnetic Resonance Venography of Brain Tumors at 3 Tesla: First Clinical Experience and Comparison with 1.5 Tesla
The DOI matches its Crossref record.
Abstract
RATIONALE AND OBJECTIVES: To evaluate the clinical potential of high-resolution 3D contrast-enhanced blood oxygenation level-dependent MR-Venography (CE-MRV) for primary brain tumors and metastases at 3 Tesla (T) in comparison to 1.5 T. METHODS: Eighteen patients with brain tumors were examined using CE-MRV after application of a standard dose of MRI contrast agent (0.1 mmol/kg gadodiamide). CE-MRV is based on a high-resolution 3D flow-compensated gradient-echo sequence with long echo times that uses the contrast-enhanced blood oxygenation level-dependent effect. This technique was performed using the same volume coverage and acquisition time at both field strengths after performing standard imaging sequences. RESULTS: The higher spatial resolution of CE-MRV at 3 T showed more details within and around tumors than at 1.5 T. Visibility was enhanced by stronger susceptibility weighting and higher intrinsic signal-to-noise at 3 T. Compared with standard imaging protocols, additional information characterized as tubular and nontubular hypointense structures were found within or around lesions on CE-MRV images. CONCLUSIONS: Acquisition of CE-MRV data at 3 T enables spatial resolution to be increased within the same measurement time and with the same volume coverage compared with 1.5 T, thus providing more detailed information. The method may also show the potential to estimate oxygen supply of tumors, especially at high field strengths.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
Self-citationClinical applications of neuroimaging with susceptibility‐weighted imaging
Sehgal, V., Delproposto, Z., Haacke, E. M., Tong, K. A., Wycliffe, N., Kido, D. K., Xu, Y., Neelavalli, J., Haddar, D., & Reichenbach, J. R. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20404 · Cited by 427
Self-citationSusceptibility-Weighted MR Imaging: A Review of Clinical Applications in Children
Tong, K. A., Ashwal, S., Obenaus, A., Nickerson, J. P., Kido, D., & Haacke, E. M. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0786 · Cited by 360
Routine clinical brain MRI sequences for use at 3.0 Tesla
Lu, H., Nagae‐Poetscher, L. M., Golay, X., Lin, D., Pomper, M., & van Zijl, P. C. M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20356 · Cited by 327
Wycliffe, N. D., Holshouser, B. A., & Ashwal, S. (2012) · Swaiman's Pediatric Neurology · doi:10.1016/b978-1-4377-0435-8.00011-1 · Cited by 255
Metadata
- Authors
- Barth, M., Nöbauer-Huhmann, I.-M., Reichenbach, J. R., Mlynárik, V., Schöggl, A., Matula, C., & Trattnig, S.
- Venue
- Investigative Radiology
- Published
- 2003-07
- Volume
- 38
- Issue
- 7
- Pages
- 409-414
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2149209048
- Cited by
- 73
- References
- 0
- FWCI
- 5.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Resolution Three-Dimensional Contrast-Enhanced Blood Oxygenation Level-Dependent Magnetic Resonance Venography of Brain Tumors at 3 Tesla: First Clinical Experience and Comparison with 1.5 Tesla. https://app.cochat.ai/papers/10.1097/01.rli.0000069790.89435.e7
- The paper
- Barth, M., Nöbauer-Huhmann, I.-M., Reichenbach, J. R., Mlynárik, V., Schöggl, A., Matula, C., & Trattnig, S. (2003). High-Resolution Three-Dimensional Contrast-Enhanced Blood Oxygenation Level-Dependent Magnetic Resonance Venography of Brain Tumors at 3 Tesla: First Clinical Experience and Comparison with 1.5 Tesla. Investigative Radiology. https://doi.org/10.1097/01.rli.0000069790.89435.e7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.