The DOI matches its Crossref record.
Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging
Abstract
MR imaging at very high field (3.0 T) is a significant new clinical tool in the modern neuroradiological armamentarium. In this report, we summarize our 40-month experience in performing clinical neuroradiological examinations at 3.0 T and review the relevant technical issues. We report on these issues and, where appropriate, their solutions. Issues examined include: increased SNR, larger chemical shifts, additional problems associated with installation of these scanners, challenges in designing and obtaining appropriate clinical imaging coils, greater acoustic noise, increased power deposition, changes in relaxation rates and susceptibility effects, and issues surrounding the safety and compatibility of implanted devices. Some of the these technical factors are advantageous (eg, increased signal-to-noise ratio), some are detrimental (eg, installation, coil design and development, acoustic noise, power deposition, device compatibility, and safety), and a few have both benefits and disadvantages (eg, changes in relaxation, chemical shift, and susceptibility). Fortunately solutions have been developed or are currently under development, by us and by others, for nearly all of these challenges. A short series of 1.5 T and 3.0 T patient images are also presented to illustrate the potential diagnostic benefits of scanning at higher field strengths. In summary, by paying appropriate attention to the discussed technical issues, high-quality neuro-imaging of patients is possible at 3.0 T.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Barber, P. A. (2005) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2004.059261 · Cited by 363
Routine clinical brain MRI sequences for use at 3.0 Tesla
Lu, H., Nagae‐Poetscher, L. M., Golay, X., Lin, D., Pomper, M., & van Zijl, P. C. M. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20356 · Cited by 327
Whole-body MRI at high field: technical limits and clinical potential
Schick, F. (2005) · European Radiology · doi:10.1007/s00330-005-2678-0 · Cited by 314
The SINAPSE Collaborative Group, Wardlaw, J. M., Brindle, W., Casado, A. M., Shuler, K., Henderson, M., Thomas, B., Macfarlane, J., Muñoz Maniega, S., Lymer, K., et al. (2012) · European Radiology · doi:10.1007/s00330-012-2500-8 · Cited by 94
Metadata
- Authors
- Frayne, R., Goodyear, B. G., Dickhoff, P., Lauzon, M. L., & Sevick, R. J.
- Venue
- Investigative Radiology
- Published
- 2003-07
- Volume
- 38
- Issue
- 7
- Pages
- 385-402
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2322779325
- Cited by
- 212
- References
- 0
- FWCI
- 18.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging. https://app.cochat.ai/papers/10.1097/01.rli.0000073442.88269.c9
- The paper
- Frayne, R., Goodyear, B. G., Dickhoff, P., Lauzon, M. L., & Sevick, R. J. (2003). Magnetic Resonance Imaging at 3.0 Tesla: Challenges and Advantages in Clinical Neurological Imaging. Investigative Radiology. https://doi.org/10.1097/01.rli.0000073442.88269.c9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.