Magnetic Resonance Imaging of the Body Trunk Using a Single-Slab, 3-Dimensional, T2-weighted Turbo-Spin-Echo Sequence With High Sampling Efficiency (SPACE) for High Spatial Resolution Imaging: Initial Clinical Experiences
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
PURPOSE: The authors conducted a clinical evaluation of single-slab, 3-dimensional, T2-weighted turbo-spin-echo (TSE) with high sampling efficiency (SPACE) for high isotropic body imaging with large field-of-view (FoV). MATERIALS AND METHODS: Fifty patients were examined in clinical routine with SPACE (regions of interest: pelvis n=30, lower spine n=12, upper spine n=6, extremities n=4) at 1.5 T. For achieving a high sampling efficiency, parallel imaging, high turbofactor, and magnetization restore pulses were used. In contrast to a conventional TSE imaging technique with constant flip angle refocusing, the refocusing pulse train of the SPACE sequence consists of variable flip angle radiofrequency pulses along the echo train. RESULTS: Signal-to-noise ratio and contrast-to-noise ratio of SPACE images were of sufficient diagnostic value. The possibility of image reconstruction in multiple planes was of clinical relevance in all cases and simplified data analysis. CONCLUSION: The achievement of 3-dimensional, T2-weighted TSE magnetic resonance imaging with isotropic and high spatial resolution and interactive 3-dimensional visualization essentially improve the diagnostic potential of magnetic resonance imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
de Bazelaire, C. M. J., Duhamel, G. D., Rofsky, N. M., & Alsop, D. C. (2004) · Radiology · doi:10.1148/radiol.2303021331 · Cited by 792
Bar‐Shalom, R., Yefremov, N., Guralnik, L., Gaitini, D. E., Frenkel, A., Kuten, A., Altman, H., Keidar, Z., & Israel, O. (2003) · PubMed · Cited by 594
Multiecho imaging sequences with low refocusing flip angles
Hennig, J. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90128-x · Cited by 403
Optimized Single-Slab Three-dimensional Spin-Echo MR Imaging of the Brain
Mugler, J. P., Bao, S., Mulkern, R. V., Guttmann, C. R. G., Robertson, R. L., Jolesz, F. A., & Brookeman, J. R. (2000) · Radiology · doi:10.1148/radiology.216.3.r00au46891 · Cited by 334
Self-citationPET/CT scanners: A hardware approach to image fusion
Townsend, D. W., Beyer, T., & Blodgett, T. M. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127314 · Cited by 262 · cited 1×
“However, such imaging fusion techniques are time-consuming and technically challenging.(23,24) The used SPACE sequence combines highly resolved (voxel size in our study only 1 mm(3)) 3D datasets with high soft tissue contrast (T2w) and is well within a tolerable examination time for clinical routine (less than 20 minu…”
Performance Evaluation of a 64-Slice CT System with z-Flying Focal Spot
Flohr, T., Stierstorfer, K., Raupach, R., Ulzheimer, S., & Bruder, H. (2004) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2004-813717 · Cited by 255
PET-CT Fusion Imaging in Differentiating Physiologic from Pathologic FDG Uptake
Kostakoglu, L., Hardoff, R., Mirtcheva, R., & Goldsmith, S. J. (2004) · RadioGraphics · doi:10.1148/rg.245035725 · Cited by 192
The sensitivity of low flip angle RARE imaging
Alsop, D. C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370206 · Cited by 170
Ibrahim, T. S., Lee, R., Abduljalil, A. M., Baertlein, B. A., & Robitaille, P.-M. L. (2001) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(01)00300-9 · Cited by 163
Benefit of anatomical-functional image fusion in the diagnostic work-up of neuroendocrine neoplasms
Pfannenberg, A. C., Eschmann, S. M., Horger, M., Lamberts, R., Vonthein, R., Claussen, C. D., & Bares, R. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1160-y · Cited by 115
Self-citationFast Whole-Body Assessment of Metastatic Disease Using a Novel Magnetic Resonance Imaging System
Schlemmer, H. P., Sch??fer, J., Pfannenberg, C., Radny, P., Korchidi, S., M??ller-Horvat, C., N??gele, T., Tomaschko, K., Fenchel, M. C., & Claussen, C. D. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000149250.37033.7c · Cited by 112
Self-citationTechnologic Advances in Abdominal MR Imaging
Keogan, M. T., & Edelman, R. R. (2001) · Radiology · doi:10.1148/radiology.220.2.r01au22310 · Cited by 111 · cited 1×
“Assessment of highly resolved anatomic data within a short examination time is essential for in-depth understanding of the pathologic process.(3,6,8) Especially in the case of surgical treatment planning, conventional 2D MRI is often not capable of visualizing all anatomic structures required for optimal preparation o…”
BackgroundSpuentrup, E., Katoh, M., Buecker, A., Manning, W. J., Schaeffter, T., Nguyen, T.-H., Kühl, H. P., Stuber, M., Botnar, R. M., & Günther, R. W. (2004) · Radiology · doi:10.1148/radiol.2312030451 · Cited by 82 · cited 1×
“A large variety of different imaging sequences are today available for this purpose(3) based mainly on gradient-echo (GRE) schemes, providing highly spatial and time-resolved 3D datasets, eg, for contrast-enhanced MR angiography.(9) Regardless of the success of T1-weighted (w) GRE 3D MRI, the need for a fast, highly r…”
BackgroundAkasu, T., Iinuma, G., Fujita, T., Muramatsu, Y., Tateishi, U., Miyakawa, K., Murakami, T., & Moriyama, N. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.184.2.01840531 · Cited by 67 · cited 1×
“Assessment of highly resolved anatomic data within a short examination time is essential for in-depth understanding of the pathologic process.(3,6,8) Especially in the case of surgical treatment planning, conventional 2D MRI is often not capable of visualizing all anatomic structures required for optimal preparation o…”
BackgroundMapping of the B1 field distribution of a surface coil resonator using EPR imaging
He, G., Evalappan, S. P., Hirata, H., Deng, Y., Petryakov, S. V., Kuppusamy, P., & Zweier, J. L. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10302 · Cited by 34
Cited by
Batchelor, T. T., Sorensen, A. G., di Tomaso, E., Zhang, W.-T., Duda, D. G., Cohen, K. S., Kozak, K. R., Cahill, D. P., Chen, P.-J., Zhu, M., et al. (2007) · Cancer Cell · doi:10.1016/j.ccr.2006.11.021 · Cited by 1,769
Brain morphometry with multiecho MPRAGE
van der Kouwe, A. J. W., Benner, T., Salat, D. H., & Fischl, B. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.025 · Cited by 596
Dimopoulos, J. C. A., Petrow, P., Tanderup, K., Petric, P., Berger, D., Kirisits, C., Pedersen, E. M., van Limbergen, E., Haie-Meder, C., & Pötter, R. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2011.12.024 · Cited by 440
Optimized three‐dimensional fast‐spin‐echo MRI
Mugler, J. P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24542 · Cited by 376
Self-citationMGH–USC Human Connectome Project datasets with ultra-high b-value diffusion MRI
Fan, Q., Witzel, T., Nummenmaa, A., Van Dijk, K. R. A., Van Horn, J. D., Drews, M. K., Somerville, L. H., Sheridan, M. A., Santillana, R. M., Snyder, J., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.075 · Cited by 254
Metadata
- Authors
- Lichy, M. P., Wietek, B. M., Mugler, J. P., Horger, W., Menzel, M. I., Anastasiadis, A., Siegmann, K., Niemeyer, T., Königsrainer, A., Kiefer, B., Schick, F., Claussen, C. D., & Schlemmer, H.-P.
- Venue
- Investigative Radiology
- Published
- 2005-12
- Volume
- 40
- Issue
- 12
- Pages
- 754-760
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2089501252
- Cited by
- 190
- References
- 15
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.