Comparison of Gd(DTPA-BMA) (Omniscan) Versus Gd(HP-DO3A) (ProHance) Relative to Gadolinium Retention in Human Bone Tissue by Inductively Coupled Plasma Mass Spectroscopy
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The objective of this study was to determine the gadolinium (Gd) concentration remaining in human bone tissue after administration of standard clinical doses of 2 Gd-based contrast agents: ProHance and Omniscan. MATERIALS AND METHODS: After administration of 0.1 mmol/kg of Gd chelate to patients undergoing hip replacement surgery, bone specimens were collected and analyzed, and compared with an age-matched control population without a history of Gd chelate administration. Bone specimens were collected fresh, refrigerated, and subsequently frozen. After grinding and freeze-drying, tissue digestion was performed using Teflon bombs and concentrated nitric acid. A method for analysis of Gd in bone specimens was developed and validated using inductively coupled plasma mass spectroscopy (ICP-MS). RESULTS: Results were compared with a previous study using a different technique for analysis of the same tissue specimens. Tissue retention was 1.77+/-0.704 microg Gd/g bone (n=9) for Omniscan and 0.477+/-0.271 microg Gd/g bone (n=10) for ProHance measured by ICP-MS. These findings confirmed results from the previous ICP-AES study. CONCLUSION: Omniscan (Gd[DTPA-BMA]) left approximately 4 times (previous study 2.5 times) more Gd behind in bone than did ProHance (Gd[HP-DO3A]).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The relationship between thermodynamics and the toxicity of gadolinium complexes
Cacheris, W. P., Quay, S. C., & Rocklage, S. M. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90055-7 · Cited by 436
Toxicity of heavy metals in the environment
(1981) · Food and Cosmetics Toxicology · doi:10.1016/0015-6264(81)90403-x · Cited by 214
Gadolinium blocks low- and high-threshold calcium currents in pituitary cells
Biagi, B. A., & Enyeart, J. J. (1990) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1990.259.3.c515 · Cited by 183
Physicochemical Properties of Gadoteridol and Other Magnetic Resonance Contrast Agents
Tweedle, M. F. (1992) · Investigative Radiology · doi:10.1097/00004424-199208001-00002 · Cited by 158
Self-citationPUTTAGUNTA, N. R., Gibby, W. A., & SMITH, G. T. (1996) · Investigative Radiology · doi:10.1097/00004424-199612000-00001 · Cited by 108
Self-citationChemInform Abstract: KINETICS AND MECHANISMS OF COMPLEX FORMATION AND LIGAND EXCHANGE
Pagenkopf, G. K. (1978) · ChemInform · doi:10.1002/chin.197847368 · Cited by 88
Cited by
Marckmann, P., Skov, L., Rossen, K., Dupont, A., Damholt, M. B., Heaf, J. G., & Thomsen, H. S. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006060601 · Cited by 1,400
Intracranial gadolinium deposition after contrast-enhanced MR imaging
McDonald, R. J., McDonald, J. S., Kallmes, D. F., Jentoft, M. E., Murray, D. L., Thielen, K. R., Williamson, E. E., & Eckel, L. J. (2015) · Radiology · doi:10.1148/radiol.15150025 · Cited by 1,358
Kanda, T., Ishii, K., Kawaguchi, H., Kitajima, K., & Takenaka, D. (2014) · Radiology · doi:10.1148/radiol.13131669 · Cited by 1,339
Kanda, T., Fukusato, T., Matsuda, M., Toyoda, K., Oba, H., Kotoku, J., Haruyama, T., Kitajima, K., & Furui, S. (2015) · Radiology · doi:10.1148/radiol.2015142690 · Cited by 874
ACR Guidance Document for Safe MR Practices: 2007
Kanal, E., Barkovich, A. J., Bell, C., Borgstede, J. P., Bradley, W. G., Froelich, J. W., Gilk, T., Gimbel, J. R., Gosbee, J., Kuhni-Kaminski, E., et al. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1616 · Cited by 787
Gadolinium deposition in the brain: summary of evidence and recommendations
Gulani, V., Calamante, F., Shellock, F. G., Kanal, E., & Reeder, S. B. (2017) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30158-8 · Cited by 784
Radbruch, A., Weberling, L. D., Kieslich, P. J., Eidel, O., Burth, S., Kickingereder, P., Heiland, S., Wick, W., Schlemmer, H.-P., & Bendszus, M. (2015) · Radiology · doi:10.1148/radiol.2015150337 · Cited by 561
Gadolinium is detectable within the tissue of patients with nephrogenic systemic fibrosis
High, W. A., Ayers, R. A., Chandler, J., Zito, G., & Cowper, S. E. (2007) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2006.10.047 · Cited by 545
Biodistribution of gadolinium‐based contrast agents, including gadolinium deposition
Aime, S., & Caravan, P. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21969 · Cited by 534
Gadolinium-Based Contrast Agent Accumulation and Toxicity: An Update
Ramalho, J., Semelka, R. C., Ramalho, M., Nunes, R. H., AlObaidy, M., & Castillo, M. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4615 · Cited by 453
Thomsen, H. S., Morcos, S. K., Almén, T., Bellin, M.-F., Bertolotto, M., Bongartz, G., Clement, O., Leander, P., Heinz-Peer, G., Reimer, P., et al. (2013) · European Radiology · doi:10.1007/s00330-012-2597-9 · Cited by 441
Errante, Y., Cirimele, V., Mallio, C. A., Di Lazzaro, V., Zobel, B. B., & Quattrocchi, C. C. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000072 · Cited by 421
Murata, N., Gonzalez-Cuyar, L. F., Murata, K., Fligner, C., Dills, R., Hippe, D., & Maravilla, K. R. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000252 · Cited by 408
Idée, J., Port, M., Raynal, I., Schaefer, M., Le Greneur, S., & Corot, C. (2006) · Fundamental & Clinical Pharmacology · doi:10.1111/j.1472-8206.2006.00447.x · Cited by 395
MRI contrast agents: Basic chemistry and safety
Hao, D., Ai, T., Goerner, F., Hu, X., Runge, V. M., & Tweedle, M. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23725 · Cited by 336
Self-citationWhat nephrologists need to know about gadolinium
Penfield, J. G., & Reilly, R. F. (2007) · Nature Clinical Practice Nephrology · doi:10.1038/ncpneph0660 · Cited by 335
Ersoy, H., & Rybicki, F. J. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21135 · Cited by 283
Iron oxide nanoclusters for T 1 magnetic resonance imaging of non-human primates
Lu, Y., Xu, Y.-J., Zhang, G.-B., Ling, D., Wang, M.-Q., Zhou, Y., Wu, Y.-D., Wu, T., Hackett, M. J., Hyo Kim, B., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0116-7 · Cited by 209
Frenzel, T., Apte, C., Jost, G., Schöckel, L., Lohrke, J., & Pietsch, H. (2017) · Investigative Radiology · doi:10.1097/rli.0000000000000352 · Cited by 208
Morcos, S. K. (2007) · The British Journal of Radiology · doi:10.1259/bjr/17111243 · Cited by 205
Toxicity of rare earth elements: An overview on human health impact
Brouziotis, A. A., Giarra, A., Libralato, G., Pagano, G., Guida, M., & Trifuoggi, M. (2022) · Frontiers in Environmental Science · doi:10.3389/fenvs.2022.948041 · Cited by 197
“1 mmol/kg) of Omniscan or Prohance a few days before surgery to patients undergoing hip replacement (Gibby et al., 2004; White et al., 2006).”
BackgroundAccumulation of rare earth elements in human bone within the lifespan
Zaichick, S., Zaichick, V., Karandashev, V., & Nosenko, S. (2011) · Metallomics · doi:10.1039/c0mt00069h · Cited by 182
Clinical Safety and Diagnostic Value of the Gadolinium Chelate Gadoterate Meglumine (Gd-DOTA)
Herborn, C. U., Honold, E., Wolf, M., Kemper, J., Kinner, S., Adam, G., & Barkhausen, J. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000248893.01067.e5 · Cited by 126
“More recently, new contrast agents have become available and been subject to safety evaluations in smaller preclinical and clinical studies.(29,30) The present study is not without its limitations.”
Background
Metadata
- Authors
- White, G. W., Gibby, W. A., & Tweedle, M. F.
- Venue
- Investigative Radiology
- Published
- 2006-03
- Volume
- 41
- Issue
- 3
- Pages
- 272-278
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2066801370
- Cited by
- 362
- References
- 6
- FWCI
- 12.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.