SMASH, SENSE, PILS, GRAPPA: How to Choose the Optimal Method
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Fast imaging methods and the availability of required hardware for magnetic resonance tomography (MRT) have significantly reduced acquisition times from about an hour down to several minutes or seconds. With this development over the last 20 years, magnetic resonance imaging (MRI) has become one of the most important instruments in clinical diagnosis. In recent years, the greatest progress in further increasing imaging speed has been the development of parallel MRI (pMRI). Within the last 3 years, parallel imaging methods have become commercially available, and therefore are now available for a broad clinical use. The basic feature of pMRI is a scan time reduction, applicable to nearly any available MRI method, while maintaining the contrast behavior without requiring higher gradient system performance. Because of its faster image acquisition, pMRI can in some cases even significantly improve image quality. In the last 10 years of pMRI development, several different pMRI reconstruction methods have been set up which partially differ in their philosophy, in the mode of reconstruction as well in their advantages and drawbacks with regard to a successful image reconstruction. In this review, a brief overview is given on the advantages and disadvantages of present pMRI methods in clinical applications, and examples from different daily clinical applications are shown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Self-citationSimultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Tsao, J., Boesiger, P., & Pruessmann, K. P. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10611 · Cited by 794
Madore, B., Glover, G. H., & Pelc, N. J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>3.0.co;2-s · Cited by 433
Partially parallel imaging with localized sensitivities (PILS)
Griswold, M. A., Jakob, P. M., Nittka, M., Goldfarb, J. W., & Haase, A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200010)44:4<602::aid-mrm14>3.0.co;2-5 · Cited by 329
Self-citationBammer, R., Keeling, S. L., Augustin, M., Pruessmann, K. P., Wolf, R., Stollberger, R., Hartung, H., & Fazekas, F. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1226 · Cited by 311
Diffusion tensor imaging using single‐shot SENSE‐EPI
Bammer, R., Auer, M., Keeling, S. L., Augustin, M., Stables, L. A., Prokesch, R. W., Stollberger, R., Moseley, M. E., & Fazekas, F. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10184 · Cited by 279
AUTO-SMASH: A self-calibrating technique for SMASH imaging
Jakob, P. M., Grisowld, M. A., Edelman, R. R., & Sodickson, D. K. (1998) · Magma: Magnetic Resonance Materials in Physics, Biology, and Medicine · doi:10.1007/bf02592256 · Cited by 278
Self-citationSensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)
Kyriakos, W. E., Panych, L. P., Kacher, D. F., Westin, C.-F., Bao, S. M., Mulkern, R. V., & Jolesz, F. A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200008)44:2<301::aid-mrm18>3.0.co;2-d · Cited by 253
Ultimate intrinsic signal‐to‐noise ratio for parallel MRI: Electromagnetic field considerations
Ohliger, M. A., Grant, A. K., & Sodickson, D. K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10597 · Cited by 238
Heidemann, R. M., Griswold, M. A., Haase, A., & Jakob, P. M. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1141 · Cited by 228
Self-citationContrast-enhanced 3D MRA using SENSE
Weiger, M., Pruessmann, K. P., Kassner, A., Roditi, G., Lawton, T., Reid, A., & Boesiger, P. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200011)12:5<671::aid-jmri3>3.0.co;2-f · Cited by 224
Cardiac real-time imaging using SENSE
Weiger, M., Pruessmann, K. P., & Boesiger, P. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200002)43:2<177::aid-mrm3>3.0.co;2-1 · Cited by 198
de Zwart, J. A., van Gelderen, P., Kellman, P., & Duyn, J. H. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10303 · Cited by 145
Combination of signals from array coils using image‐based estimation of coil sensitivity profiles
Bydder, M., Larkman, D. J., & Hajnal, J. V. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10092 · Cited by 122
Sensitivity Encoded Cardiac MRI
Pruessmann, K. P., Weiger, M., & Boesiger, P. (2001) · Journal of Cardiovascular Magnetic Resonance · doi:10.1081/jcmr-100000143 · Cited by 121
Sensitivity‐encoded single‐shot spiral imaging for reduced susceptibility artifacts in BOLD fMRI
Weiger, M., Pruessmann, K. P., Österbauer, R. A., Börnert, P., Boesiger, P., & Jezzard, P. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10286 · Cited by 118
Bydder, M., Larkman, D. J., & Hajnal, J. V. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10044 · Cited by 107
Larkman, D. J., deSouza, N. M., Bydder, M., & Hajnal, J. V. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1190 · Cited by 33
Grieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5
Cited by
What we can do and what we cannot do with fMRI
Logothetis, N. K. (2008) · Nature · doi:10.1038/nature06976 · Cited by 3,612
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822
Imaging human connectomes at the macroscale
Craddock, R. C., Jbabdi, S., Yan, C.-G., Vogelstein, J. T., Castellanos, F. X., Di Martino, A., Kelly, C., Heberlein, K., Colcombe, S., & Milham, M. P. (2013) · Nature Methods · doi:10.1038/nmeth.2482 · Cited by 419
Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion
Shin, P. J., Larson, P. E. Z., Ohliger, M. A., Elad, M., Pauly, J. M., Vigneron, D. B., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24997 · Cited by 391
Psilocybin desynchronizes the human brain
Siegel, J. S., Subramanian, S., Perry, D., Kay, B. P., Gordon, E. M., Laumann, T. O., Reneau, T. R., Metcalf, N. V., Chacko, R. V., Gratton, C., et al. (2024) · Nature · doi:10.1038/s41586-024-07624-5 · Cited by 269
Metadata
- Authors
- Blaimer, M., Breuer, F., Mueller, M., Heidemann, R. M., Griswold, M. A., & Jakob, P. M.
- Venue
- Topics in Magnetic Resonance Imaging
- Published
- 2004-08
- Volume
- 15
- Issue
- 4
- Pages
- 223-236
- ISSN
- 0899-3459 (ISSN-L)
- OpenAlex
- W2130320505
- Cited by
- 449
- References
- 22
- FWCI
- 14.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.