Accuracy of Physical Examination, Ultrasonography, and Mammography in Predicting Residual Pathologic Tumor Size in Patients Treated With Neoadjuvant Chemotherapy
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
In Brief Objective: To assess the accuracy of physical examination, ultrasonography, and mammography in predicting residual size of breast tumors following neoadjuvant chemotherapy. Background: Neoadjuvant chemotherapy is an accepted part of the management of stage II and III breast cancer. Accurate prediction of residual pathologic tumor size after neoadjuvant chemotherapy is critical in guiding surgical therapy. Although physical examination, ultrasonography, and mammography have all been used to predict residual tumor size, there have been conflicting reports about the accuracy of these methods in the neoadjuvant setting. Methods: We reviewed the records of 189 patients who participated in 1 of 2 protocols using doxorubicin-containing neoadjuvant chemotherapy, and who had assessment by physical examination, ultrasonography, and/or mammography no more than 60 days before their surgical resection. Size correlations were performed using Spearman rho analysis. Clinical and pathologic measurements were also compared categorically using the weighted kappa statistic. Results: Size estimates by physical examination, ultrasonography, and mammography were only moderately correlated with residual pathologic tumor size after neoadjuvant chemotherapy (correlation coefficients: 0.42, 0.42, and 0.41, respectively), with an accuracy of ±1 cm in 66% of patients by physical examination, 75% by ultrasonography, and 70% by mammography. Kappa values (0.24–0.35) indicated poor agreement between clinical and pathologic measurements. Conclusion: Physical examination, ultrasonography, and mammography were only moderately useful for predicting residual pathologic tumor size after neoadjuvant chemotherapy. Measurement of tumor size after neoadjuvant chemotherapy for breast cancer is an important part of clinical practice, both for assessing tumor response and for planning surgical resection. We examined the accuracy of physical examination, ultrasonography, and mammography in predicting residual tumor size following neoadjuvant chemotherapy in 189 breast cancer patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Effect of preoperative chemotherapy on the outcome of women with operable breast cancer.
Fisher, B., Bryant, J., Wolmark, N., Mamounas, E., Brown, A., Fisher, E. R., Wickerham, D. L., Begovic, M., DeCillis, A., Robidoux, A., et al. (1998) · Journal of Clinical Oncology · doi:10.1200/jco.1998.16.8.2672 · Cited by 2,165 · cited 1×
“Use of neoadjuvant chemotherapy allows for assessment of response to cytotoxic drugs in vivo, which is not only clinically relevant but also critical in terms of research endeavors assessing chemoresistance and response.(2) In addition, shrinking tumors preoperatively can make some women good candidates for breast con…”
BackgroundPartridge, S. C., Gibbs, J. E., Lu, Y., Esserman, L. J., Sudilovsky, D., & Hylton, N. M. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.5.1791193 · Cited by 341
PET Diagnostic Accuracy: Improvement with In-Line PET-CT System: Initial Results
Hany, T. F., Steinert, H. C., Goerres, G. W., Buck, A., & von Schulthess, G. K. (2002) · Radiology · doi:10.1148/radiol.2252011568 · Cited by 323
A primer of statistics for non-statisticians.
Franzblau, A. N. (1958) · Harcourt, Brace eBooks · Cited by 303
Accuracy of MRI in the Detection of Residual Breast Cancer After Neoadjuvant Chemotherapy
Rosen, E. L., Blackwell, K. L., Baker, J. A., Soo, M. S., Bentley, R. C., Yu, D., Samulski, T. V., & Dewhirst, M. W. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.5.1811275 · Cited by 278
Londero, V., Bazzocchi, M., Del Frate, C., Puglisi, F., Di Loreto, C., Francescutti, G., & Zuiani, C. (2004) · European Radiology · doi:10.1007/s00330-004-2246-z · Cited by 232
Correlating sonography, mammography, and pathology in the assessment of breast cancer size
Hieken, T. J., Harrison, J. L., Herreros, J., & Velasco, J. M. (2001) · The American Journal of Surgery · doi:10.1016/s0002-9610(01)00726-7 · Cited by 137 · cited 1×
“Studies in patients with small tumors (median size no larger than 2 cm) who did not receive neoadjuvant chemotherapy have generally shown that US gives the most accurate estimates of pathologic tumor size.(12,15) The results in studies that looked at residual tumor size after neoadjuvant chemotherapy are much more het…”
ResultBosch, A. M., Kessels, A. G. H., Beets, G. L., Jd, R., Koster, D., van Engelshoven, J. M. A., & MEYENFELDT, M. F. V. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(03)00081-0 · Cited by 127
Denis, F., Desbiez-Bourcier, A. V., Chapiron, C., Arbion, F., Body, G., & Brunereau, L. (2004) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2004.07.024 · Cited by 123 · cited 1×
“However, a recent study by Denis et al found that MRI may significantly underestimate residual disease in those patients who are treated with a taxanecontaining regimen.(26) New approaches for imaging breast tumors are being tested that are based on the function, metabolism, and molecular activity of tumor cells.”
BackgroundForouhi, P., Walsh, J. S., Anderson, T. J., & Chetty, U. (1994) · British journal of surgery · doi:10.1002/bjs.1800810221 · Cited by 79
Is there still a role for neoadjuvant therapy in breast cancer?
Shannon, C., & Smith, I. (2002) · Critical Reviews in Oncology/Hematology · doi:10.1016/s1040-8428(02)00091-4 · Cited by 61 · cited 1×
“Neoadjuvant chemotherapy has become an established part of treatment of stage II and III breast cancer, and the indications for use of this modality are constantly expanding.(1) Use of neoadjuvant chemotherapy allows for assessment of response to cytotoxic drugs in vivo, which is not only clinically relevant but also…”
BackgroundThe use of ultrasound for monitoring breast tumour response to pro-adjuvant therapy
Gawne-Cain, M. L., Smith, E. E. J., Darby, M., & Given-Wilson, R. (1995) · Clinical Radiology · doi:10.1016/s0009-9260(05)83312-4 · Cited by 23
Clinical, mammographic, and sonographic determination of preoperative breast cancer size
Fornage, B. D., Toubas, O., & Morel, M. (1987) · Cancer · doi:10.1002/1097-0142(19870815)60:4<765::aid-cncr2820600410>3.0.co;2-5
Assessment of breast cancer size: Sonographic and pathologic correlation
Tresserra, F., Feu, J., Grases, P. J., Navarro, B., Alegret, X., & Fernández-Cíd, A. (1999) · Journal of Clinical Ultrasound · doi:10.1002/(sici)1097-0096(199911/12)27:9<485::aid-jcu1>3.0.co;2-c · cited 1×
“In addition, it has been proposed that tumor grade may impact the accuracy of preoperative tumor size assessment.(14) In our study, the correlation coefficients of tumor size estimation by US and mammography compared with residual pathologic tumor size in the group with low to intermediate grade tumors (0.”
Background
Cited by
Kaufmann, M., von Minckwitz, G., Bear, H. D., Buzdar, A., McGale, P., Bonnefoi, H., Colleoni, M., Denkert, C., Eiermann, W., Jackesz, R., et al. (2007) · Annals of Oncology · doi:10.1093/annonc/mdm201 · Cited by 386
Self-citationMcDonald, B. R., Contente-Cuomo, T., Sammut, S.-J., Odenheimer-Bergman, A., Ernst, B., Perdigones, N., Chin, S.-F., Farooq, M., Mejia, R., Cronin, P. A., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aax7392 · Cited by 305
Predictors of Re-excision among Women Undergoing Breast-Conserving Surgery for Cancer
Waljee, J. F., Hu, E. S., Newman, L. A., & Alderman, A. K. (2008) · Annals of Surgical Oncology · doi:10.1245/s10434-007-9777-x · Cited by 265
Imaging Neoadjuvant Therapy Response in Breast Cancer
Fowler, A. M., Mankoff, D. A., & Joe, B. N. (2017) · Radiology · doi:10.1148/radiol.2017170180 · Cited by 242
Bossuyt, V., Provenzano, E., Symmans, W. F., Boughey, J. C., Coles, C., Curigliano, G., Dixon, J. M., Esserman, L. J., Fastner, G., Kuehn, T., et al. (2015) · Annals of Oncology · doi:10.1093/annonc/mdv161 · Cited by 240
Self-citation
Metadata
- Authors
- Chagpar, A. B., Middleton, L. P., Sahin, A. A., Dempsey, P., Buzdar, A. U., Mirza, A. N., Ames, F. C., Babiera, G. V., Feig, B. W., Hunt, K. K., Kuerer, H. M., Meric-Bernstam, F., Ross, M. I., & Singletary, S. E.
- Venue
- Annals of Surgery
- Published
- 2006-02
- Volume
- 243
- Issue
- 2
- Pages
- 257-264
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2026981776
- Cited by
- 245
- References
- 15
- FWCI
- 4.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.