Continuous Muscle Tissue Oxygenation in Critically Injured Patients: A Prospective Observational Study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Despite normalization of vital signs, critically injured patients may remain in a state of occult underresuscitation that sets the stage for sepsis, organ failure, and death. A continuous, sensitive, and accurate measure of resuscitation after injury remains elusive. METHODS: In this pilot study, we evaluated the ability of two continuous measures of peripheral tissue oxygenation in their ability to detect hypoperfusion: the Licox polarographic tissue oxygen monitor (PmO2) and the InSpectra near-infrared spectrometer (StO2). We hypothesized that deltoid muscle tissue oxygenation measurements could detect patients in "occult shock" who are at increased risk for post-injury complications. The study was designed to (1) define values for PmO2 and StO2 in patients who by all standard measures appeared to be clinically resuscitated; (2) evaluate the relationship between PmO2, StO2 and other physiologic variables including mean arterial pressure (MAP), lactate and base deficit (BD); and (3) examine the relationship between early low tissue oxygen values and the subsequent development of infections and organ dysfunction. Licox probes were inserted into the deltoid muscle of critically injured patients after initial surgical and radiologic interventions, and transcutaneous StO2 monitors were applied over the same muscle bed. PmO2, StO2, and standard physiologic data were collected continuously using a multimodal bioinformatics system. RESULTS: Twenty-eight critically injured patients were enrolled in this study at admission to the intensive care unit (ICU). For patients who appeared to be well resuscitated (defined as MAP > or = 70 mm Hg, heart rate [HR] < or = 110 bpm, BD > or = -2, and partial pressure of arterial oxygen (PaO2) = 80 and 150 mm Hg), the mean PmO2 was 34 +/- 11 mm Hg and StO2 was 63 +/- 27%. There was a strong relationship between PmO2 and BD (p < 0.001) but no significant relationship between StO2 and BD. The relationship between PmO2 and StO2 was weak but statistically significant. Early low values of both PmO2 and StO2 identified patients at risk for infectious complications or multiple organ failure (MOF). In patients who were well resuscitated by standard continuous parameters (HR and MAP), low PmO2 during the first 24 hours after admission (PmO2 < or = 25 for at least 2 hours) was strongly associated with the development of infectious complications (Odds Ratio = 16.5, 95% CI 1.49 to 183, p = 0.02). CONCLUSIONS: PmO2 is a responsive, reliable and continuous monitor of changes in base deficit. Initial low values for either PmO2 or StO2 were associated with post-injury complications. PmO2 monitoring may be useful in identifying patients in the state of occult underresuscitation who remain at risk for developing infection and MOF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Postinjury Multiple Organ Failure: A Bimodal Phenomenon
Moore, F. A., Sauaia, A., Moore, E. E., Haenel, J. B., Burch, J. M., & Lezotte, D. C. (1996) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199604000-00001 · Cited by 491
Tissue oxygenation, anemia, and perfusion in relation to wound healing in surgical patients.
JONSSON, K., JENSEN, J. A., GOODSON, W. H., SCHEUENSTUHL, H., WEST, J., HOPF, H. W., & HUNT, T. K. (1991) · Annals of Surgery · doi:10.1097/00000658-199111000-00011 · Cited by 462
Cited by
Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia
Carreau, A., Hafny‐Rahbi, B. E., Matejuk, A., Grillon, C., & Kieda, C. (2011) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2011.01258.x · Cited by 1,246
Scheeren, T. W. L., Schober, P., & Schwarte, L. A. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9348-y · Cited by 478
The prognostic value of the subjective assessment of peripheral perfusion in critically ill patients
Lima, A., Jansen, T. C., van Bommel, J., Ince, C., & Bakker, J. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819869db · Cited by 295
Postinjury multiple organ failure
Dewar, D., Moore, F. A., Moore, E. E., & Balogh, Z. (2009) · Injury · doi:10.1016/j.injury.2009.05.024 · Cited by 283
Hypoxia and the phenomenon of immune exclusion
Pietrobon, V., & Marincola, F. M. (2021) · Journal of Translational Medicine · doi:10.1186/s12967-020-02667-4 · Cited by 119
Metadata
- Authors
- Ikossi, D. G., Knudson, M. M., Morabito, D. J., Cohen, M. J., Wan, J. J., Khaw, L., Stewart, C. J., Hemphill, C., & Manley, G. T.
- Venue
- The Journal of Trauma: Injury, Infection, and Critical Care
- Published
- 2006-10
- Volume
- 61
- Issue
- 4
- Pages
- 780-790
- ISSN
- 0022-5282 (ISSN-L)
- OpenAlex
- W1986083983
- Cited by
- 105
- References
- 2
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Muscle Tissue Oxygenation in Critically Injured Patients: A Prospective Observational Study. https://app.cochat.ai/papers/10.1097/01.ta.0000239500.71419.58
- The paper
- Ikossi, D. G., Knudson, M. M., Morabito, D. J., Cohen, M. J., Wan, J. J., Khaw, L., Stewart, C. J., Hemphill, C., & Manley, G. T. (2006). Continuous Muscle Tissue Oxygenation in Critically Injured Patients: A Prospective Observational Study. The Journal of Trauma: Injury, Infection, and Critical Care. https://doi.org/10.1097/01.ta.0000239500.71419.58
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.