Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Noninvasive Evaluation of Graft Steatosis in Living Donor Liver Transplantation

Iwasaki, Minoru, Takada, Yasutsugu, Hayashi, Michihiro, Minamiguchi, Sachiko, Haga, Hironori, Maetani, Yoji, Fujii, Kazuhiro, Kiuchi, Tetsuya, Tanaka, Koichi·2004·Transplantation

Abstract

BACKGROUND: Hepatic steatosis affects graft function as well as postoperative recovery of donors in living donor liver transplantation. Liver macrovesicular steatosis in living donors was assessed using quantitative X-ray computed tomography (CT) analysis and histological examination of intraoperative liver biopsy. METHODS: A total of 266 living donors with complete pretransplant CT data and intraoperative "time 0" biopsy were included in the study. Liver biopsy specimen obtained during donor operation was examined for macrovesicular steatosis and was classified as none; mild (<30%); moderate (30%-60%); or severe (>60%). Liver-to-spleen CT attenuation values ratio (L/S ratio) on noncontrast-CT was evaluated for its usefulness as an index of hepatic steatosis in comparison with other parameters including body mass index (BMI) and serum liver function tests (gamma-glutamyl transpeptidase, alanine aminotransferase, aspartate aminotransferase, cholinesterase, and total cholesterol) using receiver operating characteristic (ROC) analysis. RESULTS.: Histological grade of macrovesicular steatosis was none in 198 patients (74.4%), mild in 50 (18.8%), moderate in 15 (5.7%), and severe in 3 (1.1%). The median L/S ratios for the respective histological grades were 1.20 (range: 1.00-1.46), 1.12 (0.83-1.37), 1.01 (0.74-1.21), and 0.90 (0.70-0.99) (P<0.0001). The ROC curve for L/S ratio was located closest to the upper left corner, and the area under the curve of L/S ratio was significantly larger than that of any other preoperative variables. CONCLUSION: L/S ratio calculated from preoperative CT can be a useful tool to discriminate hepatic macrovesicular steatosis. Based on the present results, the optimal cut-off value for L/S ratio to exclude more than moderate steatosis would be 1.1.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.tp.0000140499.23683.0d

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 230

Metadata

Authors
Iwasaki, M., Takada, Y., Hayashi, M., Minamiguchi, S., Haga, H., Maetani, Y., Fujii, K., Kiuchi, T., & Tanaka, K.
Venue
Transplantation
Published
2004-11-27
Volume
78
Issue
10
Pages
1501-1505
ISSN
0041-1337 (ISSN-L)
OpenAlex
W1988885242
Cited by
230
References
1
FWCI
5.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Evaluation of Graft Steatosis in Living Donor Liver Transplantation. https://app.cochat.ai/papers/10.1097/01.tp.0000140499.23683.0d
The paper
Iwasaki, M., Takada, Y., Hayashi, M., Minamiguchi, S., Haga, H., Maetani, Y., Fujii, K., Kiuchi, T., & Tanaka, K. (2004). Noninvasive Evaluation of Graft Steatosis in Living Donor Liver Transplantation. Transplantation. https://doi.org/10.1097/01.tp.0000140499.23683.0d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.