Electric Source Imaging in Temporal Lobe Epilepsy
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The objective of this study was to determine the validity of interictal spike (IIS) source localization in temporal lobe epilepsies (TLE) using stereoelectroencephalography as a validating method. Twenty patients with drug-resistant TLE were studied with high-resolution EEG and stereoelectroencephalography. Sixty-four scalp channels, a realistic head model, and different algorithms were used. For each patient, the intracerebral interictal distribution was studied and classified into one of three groups: L (mainly lateral), ML (mediolateral), and M (medial). In group L (three patients), surface IIS were recorded with a high signal-to-noise ratio. Source localizations designated all or part of the intracerebral interictal distribution. In group ML (11 patients), 8 patients had surface IIS, only 5 of which were localizable. High-resolution EEG permitted localization of the more lateral portion and definition of its rostrocaudal extension. A common pattern was identified in three patients with a predominant role of the temporal pole. In group M (six patients), four patients had rare surface IIS, none of which were localizable. Surface EEG does not record IIS limited to medial temporal lobe structures. In TLE with a mediolateral or a lateral interictal distribution, only the lateral component is detectable on surface EEG and accurately localizable by source localization tools.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869 · cited 1×
“…dipoles (Scherg, 1990), MUSIC (multiple signal classification) (Mosher et al., 1992), LORETA (low-resolution electromagnetic tomography) (Pascual-Marqui et al., 1994), CCD (cortical current density) reconstruction (Huppertz et al., 2001), and SPTF (spatiotemporal fit) (Schwartz et al.,…”
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Epileptic source localization with high density EEG: how many electrodes are needed?
Lantz, G., Grave de Peralta, R., Spinelli, L., Seeck, M., & Michel, C. M. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00337-1 · Cited by 413
EEG dipole modeling in complex partial epilepsy
Ebersole, J. S. (1991) · Brain Topography · doi:10.1007/bf01132768 · Cited by 132 · cited 1×
“Some authors have obtained a movement of IIS source models, suggesting propagation of IIS from the mediobasal to the lateral temporal lobe (Baumgartner et al., 1995; Ebersole, 1991; Leitjen et al., 2003).”
Background
Cited by
Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M. (2011) · Brain · doi:10.1093/brain/awr243 · Cited by 427
“Several studies suggest that anterior temporal spikes recorded on the scalp are rather the result of anterior or lateral neocortical temporal activity or common activity of neocortical and mesial temporal sources, and that neither EEG nor MEG can see spikes confined to the mesial temporal structures (Alarcon et al., 1…”
BackgroundGlutamatergic pre-ictal discharges emerge at the transition to seizure in human epilepsy
Huberfeld, G., Menendez de la Prida, L., Pallud, J., Cohen, I., Le Van Quyen, M., Adam, C., Clemenceau, S., Baulac, M., & Miles, R. (2011) · Nature Neuroscience · doi:10.1038/nn.2790 · Cited by 314
Deep brain activities can be detected with magnetoencephalography
Pizzo, F., Roehri, N., Medina Villalon, S., Trébuchon, A., Chen, S., Lagarde, S., Carron, R., Gavaret, M., Giusiano, B., McGonigal, A., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-08665-5 · Cited by 225
Self-citationGrouiller, F., Thornton, R. C., Groening, K., Spinelli, L., Duncan, J. S., Schaller, K., Siniatchkin, M., Lemieux, L., Seeck, M., Michel, C. M., et al. (2011) · Brain · doi:10.1093/brain/awr156 · Cited by 199
Lu, Y., Yang, L., Worrell, G. A., & He, B. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.11.007 · Cited by 98
Metadata
- Authors
- Gavaret, M., Badier, J.-M., Marquis, P., Bartolomei, F., & Chauvel, P.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2004-07
- Volume
- 21
- Issue
- 4
- Pages
- 267-282
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2094249816
- Cited by
- 86
- References
- 4
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electric Source Imaging in Temporal Lobe Epilepsy. https://app.cochat.ai/papers/10.1097/01.wnp.0000139929.06455.82
- The paper
- Gavaret, M., Badier, J.-M., Marquis, P., Bartolomei, F., & Chauvel, P. (2004). Electric Source Imaging in Temporal Lobe Epilepsy. Journal of Clinical Neurophysiology. https://doi.org/10.1097/01.wnp.0000139929.06455.82
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.