CoChat

Processed electroencephalogram in depth of anesthesia monitoring

Palanca, Ben Julian A, Mashour, George A, Avidan, Michael S · 2009 · Current Opinion in Anaesthesiology
Cited by 124

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

PURPOSE OF REVIEW: We critically review the principles underlying processed electroencephalogram (EEG) monitors and recent studies validating their use in monitoring anesthetic depth. RECENT FINDINGS: Depth of anesthesia is a theoretical construct to conceptualize anesthetic effects on the central nervous system as discrete or continuous phases or states. Clinical signs for assessing anesthetic depth are currently being supplemented by brain monitors. Their use may help to prevent insufficient anesthesia, which can lead to intraoperative awareness with recall, as well as anesthetic overdose, which may be associated with adverse events. Commercial and open-source brain monitoring indices are computed from frequency, entropy, or information theoretic analysis of the spontaneous or evoked EEG. These techniques are undergoing refinement to determine the best method for titrating anesthetics. Future depth-of-anesthesia monitors will benefit from current work aimed at correlating anesthetic effects to alterations in specific neural circuits. SUMMARY: Current processed EEG monitors are limited by their calibration range and the interpatient variability in their dose-response curves. The next generation of depth-of-anesthesia monitors will require a greater understanding of the transformations of cortical and subcortical activity into EEG signals, the effects of anesthetics at a systems level, and the neural correlates of consciousness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aco.0b013e3283304032

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 124

Metadata

Authors
Palanca, B. J. A., Mashour, G. A., & Avidan, M. S.
Venue
Current Opinion in Anaesthesiology
Published
2009-10
Volume
22
Issue
5
Pages
553-559
ISSN
0952-7907 (ISSN-L)
OpenAlex
W2073182347
Cited by
124
References
7
FWCI
9.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Processed electroencephalogram in depth of anesthesia monitoring. https://app.cochat.ai/papers/10.1097/aco.0b013e3283304032
The paper
Palanca, B. J. A., Mashour, G. A., & Avidan, M. S. (2009). Processed electroencephalogram in depth of anesthesia monitoring. Current Opinion in Anaesthesiology. https://doi.org/10.1097/aco.0b013e3283304032

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.